ROOM THERMOSTAT PLACEMENT  
ROOM THERMOSTAT WIRING DIAGRAM  
ENGLISH  
Room Thermostat needs to be placed in the room which is used most  
frequently. For instance; living room or lounge. Placing the Room  
Thermostat in a spot that have air circulation like entrance of a room  
or side of window should be avoided. Also anywhere close to  
heating/cooling units such as radiator, stove and spots which get  
direct sun lights would not be suitable. Room Thermostat needs to be  
located above the floor 150 cm height. Few trials may be made to find  
the most convenientspot.  
HEATING/COOLING UNIT  
DIGITAL ROOM THERMOSTAT  
generallife.com.tr  
HT250 USER MANUAL  
GENERAL SPECIFICATIONS  
NO COM  
min. 20 cm  
DIGITAL ROOM THERMOSTAT  
HT250 is a wired room thermostat. The user can adjust the room  
temperature with the required temperature and get more comfortable  
and economic heating/cooling.  
Warning!  
Operations within the heating  
/
cooling unit or the electrical  
installation must be carriedout byprofessionally qualified persons.  
PreciseTemperatureMeasurement  
Heating calibration  
ON/OFFControl  
Wired Connection  
TPIAlgorithm  
ROOM THERMOSTATTEMPERATURE CALIBRATION  
Temperature sensors which are used in Room Thermostats are highly  
sensitive. You may need to calibrate your Room Thermostat if you  
would like to get the same temperature values with other  
thermometersin yourliving space.  
Heating/Cooling Modes  
HT250  
USER MANUAL  
HT250 AND EQUIPMENTS  
Dowels and Screws  
HT250 Room Thermostat  
Alkaline Battery  
While your device is turned off, press and hold the button for 3  
seconds.  
Press the button until the “  
” menu appers. In order to see the  
desired temperature, set the temperature difference by turning the  
button to right or left. This valuecan be arranged between “-8oC" and  
“+8oC".  
BATTERY PLACEMENT  
Before starting, power off the device connected to the Room  
Thermostatand makesurethattheenergy is cutoff.  
TECHNICAL DATA  
Dimensions  
To save the settings and exit, press the "On/Off" button until the  
deviceturns off.  
Note:Recommended tempreturecalibration is “0.0oC”.  
85mm / 125mm / 24mm  
3V DC (2 x AAA alkaline battery)  
2A (30VDC – Resistive load)  
0.5A (125VAC – Resistive load)  
0.1oC  
Operating Current  
Relay NO Switching Current  
ROOM THERMOSTAT HEATING / COOLING MODES  
Your Room Thermostat has heating and cooling modes. In order to  
switcheasilybetweenheating and cooling modes:  
While your device is turned off, press and hold the button for 3  
seconds.  
Temperature Measurement  
Accuracy  
Operating Temperature Range  
Battery Life  
(5oC) – (30oC)  
1 Year (2 x AAA)  
(-10oC) – (+50oC)  
(-20oC) – (+60oC)  
Operating Temperature  
Storage Temperature  
Pressthe button until the “  
” menu appears.  
” (heating) and “  
You can switch between “  
” (cooling) modes  
” menu.  
byturning the button to right or leftin the “  
To save the settings and exit, press the button until the device turns  
off.  
ROOM THERMOSTAT  
The settings you have made have been saved. Once you turned on  
yourdevice, itwilloperatewiththe changed settings.  
As shown in the picture above, press the screwdriver forward from the  
space shown, bend the tabs and separate the front cover. Insert 2 new  
AAA alkaline batteries in the battery housing with the correct battery  
direction. Replace both batteries at the same time. Then align the  
front part of your Room Thermostat to the back and squeeze it  
towards theback.  
1
FACTORY SETTINGS RESET  
You can reset your Room Thermostat to its default factory settings.  
This operation resets the calibration setting and heating/coling  
modes to factory setting. To reset your Room Thermostat to factory  
setting:  
2
3
4
Low Battery Warning: When the “ ” icon appears on the screen, it  
means “low battery warning”. It is recommended to replace the  
batterieswhen this warning appears.  
While your device is turned off, press and hold the button for 3  
seconds.  
5
6
Pressthebutton until the“  
While in the “ “ menu, turn the button to right or left in order to  
select“ “ option and pressthebutton.  
” menu appears.  
Warning: When the product is not used for a long period (more than 15  
days), remove the batteries. Otherwise, malfunctions that may occur  
would beoutof warranty.  
1
2
3
Battery Indicator  
Room Temperature  
Set Temperature  
Cooling Indicator  
- If the Cooling Indicator is blinking, the cooling unit is working.  
- If the Cooling Indicator is steady, the cooling unit is not working.  
Heating Indicator  
Your devicewillbe turned off and resetto factory settings.  
Pleasethrowyour dead batteries into thewastebin forbatteries.  
4
5
6
- If the Heating Indicator is blinking, the heating unit is working.  
- If the Heating Indicator is steady, the heating unit is not working.  
ON/OFF and Temperature Setting Button  
generallife.com.tr  
1
2
3
GeneralDetails
NameGENERAL Life HT250 Wired Room Thermostat User Guide
MakeGENERAL LIFE
LanguageEnglish
FiletypePDF (Download)
File size2.04 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
GENERAL LIFE HT330S RF Room Thermostat User Manual
GENERAL LIFE HT330S RF Room Thermostat User Manual
GENERAL LIFE FH103S Underfloor Heating Thermostat User Manual
GENERAL LIFE FH103S Underfloor Heating Thermostat User Manual
GENERAL LIFE HT250 RF Digital Room Thermostat User Manual
GENERAL LIFE HT250 RF Digital Room Thermostat User Manual
GENERAL LIFE FH104S Underfloor Heating Thermostat User Manual
GENERAL LIFE FH104S Underfloor Heating Thermostat User Manual
GENERAL LIFE ARUNA 302S Digital Room Thermostat User Manual
GENERAL LIFE ARUNA 302S Digital Room Thermostat User Manual
GENERAL LIFE FH250S Underfloor Heating Thermostat User Manual
GENERAL LIFE FH250S Underfloor Heating Thermostat User Manual
GENERAL LIFE FC220 Digital Fan Coil Thermostat User Manual
GENERAL LIFE FC220 Digital Fan Coil Thermostat User Manual
GENERAL LIFE HT220S RF Digital Room Thermostat User Manual
GENERAL LIFE HT220S RF Digital Room Thermostat User Manual
GENERAL LIFE 270S RF Room Thermostat User Manual
GENERAL LIFE 270S RF Room Thermostat User Manual
GENERAL LIFE 270 Wireless Room Thermostat User Manual
GENERAL LIFE 270 Wireless Room Thermostat User Manual

Get the free PDF manual for the GENERAL Life HT250 Wired Room Thermostat User Guide and access setup steps, usage instructions, and troubleshooting tips. 👉 View online or download now to keep your thermostat running smoothly!

GENERAL Life HT250 Wired Room Thermostat User Guide Overview

Summary of Contents

  • Page 1: Room thermostat needs to be placed in the room which is used most frequently, such as the living room or lounge. Placing the room thermostat in spots with poor air circulation or near heating/cooling units should be avoided. Room thermostat needs to be located at a height of 150 cm above the floor. HT250 is a wired room thermostat that allows users to adjust room temperature for comfort and economic heating/cooling. Operations within the heating/cooling unit or electrical installation must be carried out by professionally qualified persons. Temperature sensors in room thermostats are highly sensitive and may require calibration for accurate readings. Your room thermostat has heating and cooling modes that can be switched easily. To reset your room thermostat to its default factory settings, specific button sequences must be followed. Low battery warning is indicated when the battery icon appears on the screen, and batteries should be replaced. When the product is not used for a long period, it is recommended to remove the batteries to prevent malfunctions.
  • Page 2: Warranty conditions state that the warranty period starts from the invoice date and covers manufacturing defects for 5 years. The TPI room thermostat uses a learning process that restarts if its placement is changed or if it is de-energized. TPI technology ensures energy efficiency by predicting temperature changes and controlling heating/cooling units accordingly. Devices are delivered in working condition, and on-site commissioning incurs a service fee. Repairs covered by the warranty must be conducted at the company's factory, with transportation costs borne by the customer for on-site services. Malfunctions caused by customer misuse are not covered by the warranty. The TPI room thermostat adapts to environmental temperature changes and minimizes energy consumption. Customers must report any product damages to maintain warranty rights. The warranty does not cover damages from external factors like fire or flooding. The warranty document must be retained by the customer, and a replacement will not be issued if lost.