SALUS RT310TX Wireless Programmable Thermostat User Guide
Button functions
DIP Switch Settings
The DIP Switches can be found on the rear of your thermostat.
RT310 / RT310TX Thermostat
RXRT510 Receiver
Control feature
Operation
TPI
Span
ON ON
RT310, RT310TX, RT310RF
Span
9CPH
1
2
3
4
±0.25°C
When TPI is selected on DIP When Span is selected
switch № 2, the DIP switch № on DIP switch № 2,
1 is functional. You can choose the DIP switch № 1 is
the Cycles Per Hour between not functional. The
a lower comfort level (6CPH) temperature accuracy of
6CPH
TPI
5
7
6
8
and
(9CPH).
a
higher comfort level your thermostat is set to
0.25 °C.
1
2
RT310 Wiring diagram
1. Turn on the LCD backlight
2. Turn On/Off the Frost Mode
3. Increase button
5. When in Manual Mode,
ON will turn the boiler on.
6. When in Manual Mode,
OFF will turn the boiler off.
AC 230 V
L
4. Decrease button
7. Receiver operates in automatic mode
according to the thermostat
8. Receiver output is controlled
by the On/Off slide switch.
MAX
3 (1) A
LCD Icon description
OR
M
Quick Guide
1. Heating Mode ON
N
1
2
3
4
5
6
2. Frost Protection Mode ON
3. RF signal indicator (only in RT310RF)
4. Low battery status
5. Temperature unit
6. Room / setpoint temperature
RT310RF Wiring diagram
Introduction
RT310 / RT310TX / RT310RF is a digital room thermosat used to control room temperature. Device
launching heating system by shorting terminal blocks, simultaneously informing the action and
showing this information on the LCD display. Before use please read this manual carefully. Use only
AA 1.5 V alkaline batteries in the thermostat. Place the batteries into the battery slot located under the
cover. Do not use rechargeable batteries.
Note: If you are using the RT310RF pack, the pairing between the thermostat and the receiver
is already done.
RT310 Terminals description
Product compliance
This product complies with the essential requirements and other relevant provisions of the following EU Directives:
EMC 2014/30/EU, LVD 2014/35/EU, RED 2014/53/EU and RoHS 2011/65/EU. Full text of the EU Declaration of
Terminal
1 - COM
2 - NC
Description
Common Terminal
Switched Live OFF
Switched Live ON
N
L
868.0-868.6MHz; <13dBm
COM
3 - NO
Safety Information
NO
Use in accordance to national and EU regulations. Use the device as intended, keeping it in dry condition.
Product for indoor use only. Installation must be carried out by a qualified person in accordance to
national and EU regulations.
N
L
Technical specification
RT310
RT310TX
RXRT510 Receiver terminals description
Thermostat supply
Receiver supply
2 x AA alkaline batteries
2 x AA alkaline batteries
N
L
Terminal
NO
Description
-
230 V AC
-
Switch Terminal
COM
NO
Thermostat rating max
Receiver rating max
3 (1) A
-
COM
Common Switch Terminal
Supply (230 V AC)
16 (5) A
MAX
16 (5) A
OR
NO COM
L
N
N
L
L, N
Voltage free
NO / COM /NC terminals
Voltage free
NO / COM terminals
M
Outputs
Temperature range
5 - 35°C
5 - 35°C
| General | Details |
|---|---|
| Name | SALUS RT310TX Wireless Programmable Thermostat User Guide |
| Make | SALUS |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.24 MB |

SALUS IT800 WIFI Smart Thermostat Installation Guide

SALUS 091FLRF Wireless Room Thermostat User Guide

SALUS Thermostat Sensor TS600 User Guide

SALUS Thermostat and Smart Plug Installation Guide

SALUS Programmable Wired Thermostat VS30W/VS30B Installation Guide

SALUS Wired Thermostat Installation Guide

SALUS Wired Digital Thermostat – Non-programmable HTRS230 User Manual

SALUS RT520 Radiator Thermostat User Guide

SALUS RT310 Thermostat User Manual

SALUS Thermostat RT520 User Manual

SALUS RT310TX Wireless Programmable Thermostat User Guide Overview
Summary of Contents
- Page 1: Button functions DIP Switch Settings The DIP Switches can be found on the rear of your thermostat. RT310 / RT310TX Thermostat RXRT510 Receiver Control feature Operation TPI Span RT310 Wiring diagram Introduction RT310 / RT310TX / RT310RF is a digital room thermostat used to control room temperature. Device launching heating system by shorting terminal blocks, simultaneously informing the action and showing this information on the LCD display. Before use please read this manual carefully. Use only AA 1.5 V alkaline batteries in the thermostat. Place the batteries into the battery slot located under the cover. Do not use rechargeable batteries. Product compliance This product complies with the essential requirements and other relevant provisions of the following EU Directives: EMC 2014/30/EU, LVD 2014/35/EU, RED 2014/53/EU and RoHS 2011/65/EU. Full text of the EU Declaration of Conformity is available on www.saluslegal.com. Safety Information Use in accordance to national and EU regulations. Use the device as intended, keeping it in dry condition. Product for indoor use only. Installation must be carried out by a qualified person in accordance to national and EU regulations. Technical specification Thermostat supply: 2 x AA alkaline batteries Receiver supply: 2 x AA alkaline batteries
- Page 2: Change the setpoint temperature. Pairing the RT310TX with the receiver. If you bought the RT310TX and RXRT510 separately or want to re-pair, ensure the device is disconnected from power. The red LED will light steadily to confirm pairing mode. Press and hold the TEST / PAIRING button for 3 seconds to end the pairing process. Your thermostat will be reset and will start up automatically. The frost protection setpoint temperature ranges from 5.0°C to 17.0°C. When changing batteries, you have 30 seconds to replace them before losing settings. If the low battery symbol is not noticed, the thermostat will shut down. When Sleep Mode is active, all thermostat functions will be paused.