Home > EPH CONTROLS > EPH CONTROLS CRTP2 Room Thermostat Instruction Manual
EPH CONTROLS CRTP2 Room Thermostat Instruction Manual
Page 1 of 3
Operating Instructions
CRTP2 Room Thermostat Battery Operated
Contents
1. Factory default settings
2. Specification & wiring
3. Mounting
CAUTION!
4. Installation
5. Wiring diagram
6. Frost protection
Before commencing any work on the electrical
connections, you must first disconnect the thermostat
from the mains. None of the 230V connections must be
live until the installation has been completed and the
housing is closed. Only qualified electricians or authorised
service staff are permitted to open the thermostat.
7. Button / symbol description
8. Resetting the thermostat
9. Keypad lock and unlock
10. Setting the date, time and operating mode
11. Factory default program settings
12. Adjusting the program settings for 5/2d
13. Temporary override (Manual)
14. Permanent override (Hold)
15. Adjusting the switching differential
16. Replacing the batteries
17. Installer Menu
There are parts that may carry mains voltage behind the
cover. The thermostat must not be left unsupervised
when open. (Prevent non specialists and especially
children from gaining access to it.)
Important:
Keep this document
Prior to setting the thermostat, it is neccessary to complete all required settings described in this section.
1. Factory default settings
5. Wiring diagram
Contacts:
Volt Free
INTERNAL WIRING DIAGRAM CRTP2
3
2
1
Temperature indicator:
Switching differential:
In built frost protection:
°C
0.4°C
5°C
ON COM
High and Low temp. limitation: Off
If mains voltage output is required, 230V must be connected to terminal 2.
Clock:
24 hours
Off
Keypad lock:
5°C
6. Frost protection
2. Specifications & wiring
Frost protection is built into this thermostat, it is pre fixed at 5°C and is not
adjustable.
Power supply:
2 x AA Alkaline Battery
8 VA
Power consumption:
Temp. control range:
Ambient temperature:
Contact rating:
It will only be activated when the thermostat is in the stand by mode and
the room temperature reaches 5°C.
5 ... 35°C
0 ... 50°C
8A 230Vac
Dimensions:
84 x 84 x 30mm
Temperature sensor:
Switching differential:
Frost protection:
NTC 10K Ohm @ 25°C
Adjustable from 0.2/0.4/0.6/0.8/1.0˚C
Only operational in stand by mode
7. Button / Symbol description
Keypad lock symbol
Heating ON symbol
Current programme
3. Mounting
The mounting height should be 1.5 meters above the floor level.
The thermostat should be wall mounted in the room where the heating is to
be controlled.
The place of installation should be chosen so that the sensor can measure the
room temperature as accurately as possible.
Day of the week
Program
P3
Choose the mounting location to prevent direct exposure to sunlight or other
heating / cooling sources when mounted.
On / Standby symbol
Reset button
The unit can be fitted to:
1. Recessed conduit boxes
2. Surface mounting boxes
3. Directly on walls.
Set point increase
Set point decrease
OK button
Hold button
4. Installation
On / Standby button
Set button
Slacken the fastening screw on the bottom of the thermostat with a philips
head screwdriver.
The thermostat is hinged and can be opened 180 degrees.
Mount the unit as described in section 3.
Wire the thermostat according to the wiring diagram.
Close the thermostat and tighten the fastening screw.
EPH Controls Ireland
EPH Controls UK
20221013_CRTP2_OpIns_PK
| General | Details |
|---|---|
| Name | EPH CONTROLS CRTP2 Room Thermostat Instruction Manual |
| Make | EPH CONTROLS |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.25 MB |

EPH CONTROLS eTRV-HW Smart Cylinder Thermostat User Guide

EPH CONTROLS eTRV-HW Smart Hot Water Thermostat Instruction Manual

EPH CONTROLS eTRV Smart Radiator Thermostat Instruction Manual

EPH CONTROLS 20221026 RFRA – RF Room Thermostat Instruction Manual

EPH CONTROLS CDTP2 Hardwired Room Thermostat Instruction Manual

EPH Controls CDT2-24 24V Room Thermostat Installation Guide

EPH CONTROLS RFCA RF Cylinder Thermostat Instruction Manual

EPH CONTROLS PR092K7 RF Cylinder Thermostat Instruction Manual

EPH CONTROLS COMBIPACK2 Smart Thermostat with Automation and Optimum Start Instructions

EPH CONTROLS RFR RF Room Thermostat Instruction Manual

EPH CONTROLS CRTP2 Room Thermostat Instruction Manual Overview
Summary of Contents
- Page 1: Operating instructions for CRTP2 room thermostat, battery operated. Factory default settings. Specification and wiring. Mounting height should be 1.5 meters above the floor level. The thermostat should be wall mounted in the room where heating is to be controlled. Frost protection is built into this thermostat, pre-fixed at 5°C and not adjustable. Power supply requires 2 x AA alkaline batteries. Temperature control range is from 5 to 35°C. The thermostat must not be left unsupervised when open. The unit can be fitted to recessed conduit boxes, surface mounting boxes, or directly on walls.
- Page 2: Operating instructions CRTP2 room thermostat battery operated Adjusting the program settings for 5/2d It is necessary to reset the thermostat prior to initial programming. Programming for Monday to Friday is now selected. If 7 D mode is selected, you can program each day of the week with 6 individual times and temperatures. Temporary override (manual) allows the thermostat to switch to the temperature set by the user until the next program is activated. Permanent override (hold) allows the thermostat to operate to the temperature set by the user. Factory program setting for 5/2d includes specific times and temperatures for weekdays and weekends. Replacing the batteries requires slacking the fastening screw and using 2 x AA alkaline batteries. The thermostat is hinged and can be opened 180 degrees.
- Page 3: Operating instructions for CRTP2 room thermostat, battery operated. Installer menu access requires holding OK for 5 seconds. In normal mode, the thermostat aims to reach the target temperature after program changes. Optimum start mode allows the thermostat to reach the target temperature by the next switching time. Ti (time interval) can be set to 10, 15, or 20 minutes to increase room temperature by 1°C. The thermostat reads room temperature, setpoint temperature, and target temperature difference. Optimum start time (OST) can be a maximum of 3 hours, which is subtracted from the start time. The thermostat recalculates OST if the temperature increases too quickly. Examples illustrate how the thermostat adjusts heating times based on Ti settings.