Operating Instructions
RFRA - RF Room Thermostat
Contents
1. Factory default settings
2. Specification & wiring
3. Mounting
CAUTION!
4. Installation
Only qualified electricians or authorised
service staff are permitted to open the
thermostat.
5. Button / symbol description
6. Resetting the thermostat
7. Adjusting the setpoint temperature
8. On / Off function
Ensure that this wireless enabled
thermostat is installed 1 metre from any
metalic object, television, radio or
wireless internet transmitter.
9. Lock function
10. To connect the RFRA thermostat to the
RF1 receiver
11. To disconnect the RFRA thermostat from
the RF1receiver
Important: Keep this document
Prior to setting the thermostat, it is neccessary to complete all required settings
described in this section.
5. Button / symbol description
1. Factory default settings
Wireless symbol
Temperature indicator:
Switching differential:
In built frost protection:
Keypad lock:
°C
Heating ON symbol
Room temperature
0.2°C
5°C
Off
Battery low symbol
On / Off button
Set point handwheel
2. Specifications & wiring
Power Supply:
2 x AAA Alkaline Battery
50 uA
Power consumption:
Battery replacement:
Temp. Control Range:
Dimensions:
Once per year
5...35°C
84 * 84 * 30mm
NTC 10K Ohm @ 25°C
°C
Temp. sensor:
Temp. indication:
Reset button Code button
3. Mounting
The mounting height should be 1.5 meters above the floor level. The
thermostat should be wall mounted in the room where the heating is to
be controlled.
6. Resetting the thermostat
Press the
button on the bottom of the thermostat, the front housing
will detach from the baseplate.
The place of installation should be chosen so that the sensor can measure
the room temperature as accurately as possible.
Insert the batteries into the thermostat.
Press the reset button on the PCB, ‘NO’will flash on the screen.
Rotate the hand wheel clockwise until ‘YES’appears on the screen.
Press the hand wheel once to confirm the setting.
Choose the mounting location to prevent direct exposure to sunlight or
other heating / cooling sources when mounted.
The unit can be fitted to:
1. Recessed conduit boxes
2. Surface mounting boxes
3. Directly on walls
The thermostat has now been reset and the current temperature will
appear on the screen.
4. Table mounting with stand provided
4. Installation
7. Adjusting the setpoint temperature
Press the button on the bottom of the thermostat.
The front housing will detach from the baseplate.
Insert the batteries (provided) into the thermostat.
Mount the unit as described in section 3.
Rotate
Press
clockwise to increase the target temperature.
or wait 5 seconds. The target temperature is now saved.
anti-clockwise to decrease the target temperature.
or wait 5 seconds. The target temperature is now saved.
Rotate
Press
Offer the baseplate up to the thermostat. Snap it into position to close.
EPH Controls Ireland
EPH Controls UK
20221026_RFRA_OpIns_PK
| General | Details |
|---|---|
| Name | EPH CONTROLS 20221026 RFRA – RF Room Thermostat Instruction Manual |
| Make | EPH CONTROLS |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.11 MB |

EPH CONTROLS eTRV-HW Smart Cylinder Thermostat User Guide

EPH CONTROLS eTRV-HW Smart Hot Water Thermostat Instruction Manual

EPH CONTROLS eTRV Smart Radiator Thermostat Instruction Manual

EPH CONTROLS CDTP2 Hardwired Room Thermostat Instruction Manual

EPH Controls CDT2-24 24V Room Thermostat Installation Guide

EPH CONTROLS RFCA RF Cylinder Thermostat Instruction Manual

EPH CONTROLS PR092K7 RF Cylinder Thermostat Instruction Manual

EPH CONTROLS COMBIPACK2 Smart Thermostat with Automation and Optimum Start Instructions

EPH CONTROLS CRT2 Room Thermostat Instruction Manual

EPH CONTROLS CDC2 Cylinder Room Thermostat User Guide

EPH CONTROLS 20221026 RFRA – RF Room Thermostat Instruction Manual Overview
Summary of Contents
- Page 1: Operating instructions for the RFRA - RF room thermostat include important sections on factory default settings, specifications and wiring, and mounting guidelines. Qualified electricians or authorized service staff are permitted to open the thermostat. The thermostat should be installed 1 meter from any metallic object, television, radio, or wireless internet transmitter. The mounting height should be 1.5 meters above the floor level, and it should be wall-mounted in the room where heating is to be controlled. To reset the thermostat, press the button on the bottom, detach the front housing, and follow the on-screen instructions. Choose a mounting location that avoids direct exposure to sunlight or other heating/cooling sources. The thermostat can be fitted to recessed conduit boxes, surface mounting boxes, directly on walls, or table mounting with a stand. To adjust the setpoint temperature, rotate the handwheel clockwise to increase or anti-clockwise to decrease the target temperature. Press the handwheel to confirm the setting after adjusting the temperature. Insert the provided batteries into the thermostat during installation.
- Page 2: Operating instructions RFRA - RF room thermostat On / Off function By pressing the On / Off button, this turns the thermostat on and off. Lock function To lock the thermostat, press the hand wheel for 10 seconds. To unlock the thermostat, press the hand wheel for 10 seconds. To connect the RFRA thermostat to the RF1 receiver Press the connect button on the RF1 receiver. Press the button on the bottom of the thermostat, the front housing will detach from the baseplate. Press the CODE button on the printed circuit board. To disconnect the RFRA thermostat from the RF1 receiver Press the reset button on the RF1 receiver. Press the button on the bottom of the thermostat, the front housing will detach from the baseplate. Press the RESET button on the printed circuit board.