Operating Instructions
RFR - RF Room Thermostat
Contents
1. Factory default settings
2. Specification & wiring
3. Mounting
CAUTION!
4. Installation
5. Button / symbol description
6. Resetting the thermostat
7. Adjusting the setpoint temperature
8. Boost function
Only qualified electricians or authorised
service staff are permitted to open the
thermostat.
9. Lock function
10. To connect the RFR thermostat to the
R_7-RF programmer
11. To disconnect the RFR thermostat from
the R_7-RF programmer
Ensure that this wireless enabled
thermostat is installed 1 metre from any
metalic object, television, radio or wireless
internet transmitter.
Important: Keep this document
Prior to setting the thermostat, it is neccessary to complete all required settings
described in this section.
1. Factory default settings
5. Button / symbol description
Temperature indicator:
Switching differential:
In built frost protection:
Keypad lock:
°C
Wireless symbol
0.4°C
5°C
Off
Heating ON symbol
Room temperature
Battery low symbol
Boost button
2. Specifications & wiring
Set point handwheel
Power Supply:
2 x AAA Alkaline Battery
50 uA
Power consumption:
Battery replacement:
Temp. Control Range:
Dimensions:
Once per year
5...35°C
84 * 84 * 30mm
NTC 10K Ohm @ 25°C
°C
Temp. sensor:
Temp. indication:
Code button
Reset button
3. Mounting
The mounting height should be 1.5 meters above the floor level. The
thermostat should be wall mounted in the room where the heating is to
be controlled.
6. Resetting the thermostat
Press the
button on the bottom of the thermostat, the front housing
The place of installation should be chosen so that the sensor can measure
the room temperature as accurately as possible.
will detach from the baseplate.
Insert the batteries into the thermostat.
Choose the mounting location to prevent direct exposure to sunlight or
other heating / cooling sources when mounted.
Press the reset button on the PCB, ‘NO’will flash on the screen.
Rotate the hand wheel clockwise until ‘YES’appears on the screen.
Press the hand wheel once to confirm the setting.
The unit can be fitted to:
1. Recessed conduit boxes
2. Surface mounting boxes
3. Directly on walls
The thermostat has now been reset and the current temperature will
appear on the screen.
4. Table mounting with stand provided
4. Installation
7. Adjusting the setpoint temperature
Press the button on the bottom of the thermostat.
The front housing will detach from the baseplate.
Insert the batteries (provided) into the thermostat.
Mount the unit as described in section 3.
Rotate
Press
clockwise to increase the target temperature.
or wait 5 seconds. The target temperature is now saved.
anti-clockwise to decrease the target temperature.
or wait 5 seconds. The target temperature is now saved.
Rotate
Press
Offer the baseplate up to the thermostat. Snap it into position to close.
EPH Controls Ireland
EPH Controls UK
2023-03-10_RFR_OpIns_PK
| General | Details |
|---|---|
| Name | EPH CONTROLS 2023-03-10 RFR-RF Room Thermostat Instruction Manual |
| Make | EPH CONTROLS |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.11 MB |

EPH CONTROLS eTRV-HW Smart Cylinder Thermostat User Guide

EPH CONTROLS eTRV-HW Smart Hot Water Thermostat Instruction Manual

EPH CONTROLS eTRV Smart Radiator Thermostat Instruction Manual

EPH CONTROLS 20221026 RFRA – RF Room Thermostat Instruction Manual

EPH CONTROLS CDTP2 Hardwired Room Thermostat Instruction Manual

EPH Controls CDT2-24 24V Room Thermostat Installation Guide

EPH CONTROLS COMBIPACK2 Smart Thermostat with Automation and Optimum Start Instructions

EPH CONTROLS RFCA RF Cylinder Thermostat Instruction Manual

EPH CONTROLS PR092K7 RF Cylinder Thermostat Instruction Manual

EPH CONTROLS CRT2 Room Thermostat Instruction Manual

EPH CONTROLS 2023-03-10 RFR-RF Room Thermostat Instruction Manual Overview
Summary of Contents
- Page 1: Operating instructions for the RFR - RF room thermostat include essential sections such as factory default settings, specifications and wiring, mounting, installation, button and symbol descriptions, resetting the thermostat, adjusting the setpoint temperature, and the boost function. Only qualified electricians or authorized service staff are permitted to open the thermostat. Ensure that the wireless-enabled thermostat is installed 1 meter from any metallic object, television, radio, or wireless internet transmitter. The mounting height should be 1.5 meters above the floor level, and the thermostat should be wall-mounted in the room where the heating is to be controlled. The thermostat has a temperature control range of 5 to 35°C and requires 2 x AAA alkaline batteries for power. To reset the thermostat, press the reset button on the PCB and follow the on-screen prompts. Choose the mounting location to prevent direct exposure to sunlight or other heating/cooling sources. Rotate the hand wheel clockwise to increase or anti-clockwise to decrease the target temperature. The unit can be fitted to recessed conduit boxes, surface mounting boxes, directly on walls, or table mounting with a stand provided.
- Page 2: Operating instructions for the RFR - RF room thermostat include several key functions. The boost function allows users to increase heating for 1, 2, or 3 hours by pressing the boost button. The lock function secures the thermostat by pressing the hand wheel for 10 seconds, with a keypad symbol indicating the lock status. To connect the RF thermostat with the programmer, users must set the timeswitch to the RUN position and press a button for 5 seconds to initiate wireless connection. The wireless room thermostat will display the zone it is paired to after pressing the corresponding zone button. To disconnect the RF thermostat from the programmer, users can clear all RF connections by pressing a button for 5 seconds. The timeswitch will then operate in wireless mode, displaying the temperature from the wireless thermostat. Users can repeat the connection process for additional zones if needed. The document includes references to EPH Controls for technical support. The instructions emphasize the importance of following the steps for successful connection and disconnection of the thermostat.