Home > EPH CONTROLS > EPH CONTROLS 2023-03-10 RFR-RF Room Thermostat Instruction Manual

EPH CONTROLS 2023-03-10 RFR-RF Room Thermostat Instruction Manual

Page 1 of 2  
Operating Instructions  
RFR - RF Room Thermostat  
Contents  
1. Factory default settings  
2. Specification & wiring  
3. Mounting  
CAUTION!  
4. Installation  
5. Button / symbol description  
6. Resetting the thermostat  
7. Adjusting the setpoint temperature  
8. Boost function  
Only qualified electricians or authorised  
service staff are permitted to open the  
thermostat.  
9. Lock function  
10. To connect the RFR thermostat to the  
R_7-RF programmer  
11. To disconnect the RFR thermostat from  
the R_7-RF programmer  
Ensure that this wireless enabled  
thermostat is installed 1 metre from any  
metalic object, television, radio or wireless  
internet transmitter.  
Important: Keep this document  
Prior to setting the thermostat, it is neccessary to complete all required settings  
described in this section.  
1. Factory default settings  
5. Button / symbol description  
Temperature indicator:  
Switching differential:  
In built frost protection:  
Keypad lock:  
°C  
Wireless symbol  
0.4°C  
5°C  
Off  
Heating ON symbol  
Room temperature  
Battery low symbol  
Boost button  
2. Specifications & wiring  
Set point handwheel  
Power Supply:  
2 x AAA Alkaline Battery  
50 uA  
Power consumption:  
Battery replacement:  
Temp. Control Range:  
Dimensions:  
Once per year  
5...35°C  
84 * 84 * 30mm  
NTC 10K Ohm @ 25°C  
°C  
Temp. sensor:  
Temp. indication:  
Code button  
Reset button  
3. Mounting  
The mounting height should be 1.5 meters above the floor level. The  
thermostat should be wall mounted in the room where the heating is to  
be controlled.  
6. Resetting the thermostat  
Press the  
button on the bottom of the thermostat, the front housing  
The place of installation should be chosen so that the sensor can measure  
the room temperature as accurately as possible.  
will detach from the baseplate.  
Insert the batteries into the thermostat.  
Choose the mounting location to prevent direct exposure to sunlight or  
other heating / cooling sources when mounted.  
Press the reset button on the PCB, ‘NOwill flash on the screen.  
Rotate the hand wheel clockwise until ‘YESappears on the screen.  
Press the hand wheel once to confirm the setting.  
The unit can be fitted to:  
1. Recessed conduit boxes  
2. Surface mounting boxes  
3. Directly on walls  
The thermostat has now been reset and the current temperature will  
appear on the screen.  
4. Table mounting with stand provided  
4. Installation  
7. Adjusting the setpoint temperature  
Press the button on the bottom of the thermostat.  
The front housing will detach from the baseplate.  
Insert the batteries (provided) into the thermostat.  
Mount the unit as described in section 3.  
Rotate  
Press  
clockwise to increase the target temperature.  
or wait 5 seconds. The target temperature is now saved.  
anti-clockwise to decrease the target temperature.  
or wait 5 seconds. The target temperature is now saved.  
Rotate  
Press  
Offer the baseplate up to the thermostat. Snap it into position to close.  
EPH Controls Ireland  
EPH Controls UK  
2023-03-10_RFR_OpIns_PK  
GeneralDetails
NameEPH CONTROLS 2023-03-10 RFR-RF Room Thermostat Instruction Manual
MakeEPH CONTROLS
LanguageEnglish
FiletypePDF (Download)
File size0.11 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
EPH CONTROLS eTRV-HW Smart Cylinder Thermostat User Guide
EPH CONTROLS eTRV-HW Smart Cylinder Thermostat User Guide
EPH CONTROLS eTRV-HW Smart Hot Water Thermostat Instruction Manual
EPH CONTROLS eTRV-HW Smart Hot Water Thermostat Instruction Manual
EPH CONTROLS eTRV Smart Radiator Thermostat Instruction Manual
EPH CONTROLS eTRV Smart Radiator Thermostat Instruction Manual
EPH CONTROLS 20221026 RFRA – RF Room Thermostat Instruction Manual
EPH CONTROLS 20221026 RFRA – RF Room Thermostat Instruction Manual
EPH CONTROLS CDTP2 Hardwired Room Thermostat Instruction Manual
EPH CONTROLS CDTP2 Hardwired Room Thermostat Instruction Manual
EPH Controls CDT2-24 24V Room Thermostat Installation Guide
EPH Controls CDT2-24 24V Room Thermostat Installation Guide
EPH CONTROLS COMBIPACK2 Smart Thermostat with Automation and Optimum Start Instructions
EPH CONTROLS COMBIPACK2 Smart Thermostat with Automation and Optimum Start Instructions
EPH CONTROLS RFCA RF Cylinder Thermostat Instruction Manual
EPH CONTROLS RFCA RF Cylinder Thermostat Instruction Manual
EPH CONTROLS PR092K7 RF Cylinder Thermostat Instruction Manual
EPH CONTROLS PR092K7 RF Cylinder Thermostat Instruction Manual
EPH CONTROLS CRT2 Room Thermostat Instruction Manual
EPH CONTROLS CRT2 Room Thermostat Instruction Manual

EPH CONTROLS 2023-03-10 RFR-RF Room Thermostat Instruction Manual
Get the free PDF manual for the EPH CONTROLS 2023-03-10 RFR-RF Room Thermostat Instruction Manual and access setup steps, usage instructions, and troubleshooting tips. 👉 View online or download now to keep your thermostat running smoothly!

EPH CONTROLS 2023-03-10 RFR-RF Room Thermostat Instruction Manual Overview

Summary of Contents

  • Page 1: Operating instructions for the RFR - RF room thermostat include essential sections such as factory default settings, specifications and wiring, mounting, installation, button and symbol descriptions, resetting the thermostat, adjusting the setpoint temperature, and the boost function. Only qualified electricians or authorized service staff are permitted to open the thermostat. Ensure that the wireless-enabled thermostat is installed 1 meter from any metallic object, television, radio, or wireless internet transmitter. The mounting height should be 1.5 meters above the floor level, and the thermostat should be wall-mounted in the room where the heating is to be controlled. The thermostat has a temperature control range of 5 to 35°C and requires 2 x AAA alkaline batteries for power. To reset the thermostat, press the reset button on the PCB and follow the on-screen prompts. Choose the mounting location to prevent direct exposure to sunlight or other heating/cooling sources. Rotate the hand wheel clockwise to increase or anti-clockwise to decrease the target temperature. The unit can be fitted to recessed conduit boxes, surface mounting boxes, directly on walls, or table mounting with a stand provided.
  • Page 2: Operating instructions for the RFR - RF room thermostat include several key functions. The boost function allows users to increase heating for 1, 2, or 3 hours by pressing the boost button. The lock function secures the thermostat by pressing the hand wheel for 10 seconds, with a keypad symbol indicating the lock status. To connect the RF thermostat with the programmer, users must set the timeswitch to the RUN position and press a button for 5 seconds to initiate wireless connection. The wireless room thermostat will display the zone it is paired to after pressing the corresponding zone button. To disconnect the RF thermostat from the programmer, users can clear all RF connections by pressing a button for 5 seconds. The timeswitch will then operate in wireless mode, displaying the temperature from the wireless thermostat. Users can repeat the connection process for additional zones if needed. The document includes references to EPH Controls for technical support. The instructions emphasize the importance of following the steps for successful connection and disconnection of the thermostat.