INSTRUCTION  
Radiator Thermostat RAS-C2 Combi  
BI-DIRECTIONAL VALVE WITH FLOW-SELECTABLE FEATURE  
Installation of valve  
Troubleshooting  
The valve is a bi-directional valve * and can be installed  
horizontally or vertically in either the flow or return  
pipe.  
A built in flow direction selection feature can be used to  
eliminate the risk of water hammer.  
In the unlikely event of water hammer being encountered  
turn the setting ring (see diagram 4) to the other setting.  
Alternatively if commissioning the whole system,  
establish the flow direction through each valve using  
the diagrams below.  
If the flow direction needs to be changed there is  
no need to remove the valve, simply turn the setting  
ring.  
2
3
1
Start boiler/heating.  
Open one valve and determine  
flow direction. Which pipe heats  
first?  
Close all radiator valves by turning  
the valve cover cap clockwise.  
Leave system to cool.  
Keymark reference: This package contains sensor 013G6040, valve 013G6281 (15mm) or valve 013G6283 (8/10 mm)  
Setting ring  
4
Remove cap and turn setting  
ring according to the drawings -  
the setting ring is turned by hand  
only.  
5
Repeat step 3 and 4 until all valves have  
been set correctly. Sensor may now be fit-  
ted or the valve cap temporarily refitted.  
VISXM302/Danfoss DKCD 05/2011  
* Maximum pressure drop should not exceed 0.45 bar  
GeneralDetails
NameDanfoss 013R9355 Radiator Thermostat Instructions
MakeDanfoss
LanguageEnglish
FiletypePDF (Download)
File size0.08 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
Danfoss RET-MD Electronic Intelligent Dial Setting Thermostat Installation Guide
Danfoss RET-MD Electronic Intelligent Dial Setting Thermostat Installation Guide
Danfoss VICUQ24M Icon Programmable II Room Thermostat Installation Guide
Danfoss VICUQ24M Icon Programmable II Room Thermostat Installation Guide
Danfoss MBC 8000, MBC 8100 Heavy Duty Thermostat Installation Guide
Danfoss MBC 8000, MBC 8100 Heavy Duty Thermostat Installation Guide
Danfoss UT 72-UT 73 Universal Thermostat Installation Guide
Danfoss UT 72-UT 73 Universal Thermostat Installation Guide
Danfoss ECtemp 530 Electronic Thermostat Installation Guide
Danfoss ECtemp 530 Electronic Thermostat Installation Guide
Danfoss 014G0251 Eco Radiator Thermostat User Guide
Danfoss 014G0251 Eco Radiator Thermostat User Guide
Danfoss 014G0013 Z Wave Radiator Thermostat Installation Guide
Danfoss 014G0013 Z Wave Radiator Thermostat Installation Guide
Danfoss RET230P Electronic Thermostat Instruction Manual
Danfoss RET230P Electronic Thermostat Instruction Manual
Danfoss TP7000 Range Electronic 7 Day Programmable Room Thermostat Installation Guide
Danfoss TP7000 Range Electronic 7 Day Programmable Room Thermostat Installation Guide
Danfoss RET1000 Series Electronic Thermostat User Guide
Danfoss RET1000 Series Electronic Thermostat User Guide

Danfoss 013R9355 Radiator Thermostat Instructions
Get the free PDF manual for the Danfoss 013R9355 Radiator Thermostat Instructions and access setup steps, usage instructions, and troubleshooting tips. 👉 View online or download now to keep your thermostat running smoothly!

Danfoss 013R9355 Radiator Thermostat Instructions Overview

Summary of Contents

  • Page 1: Radiator thermostat RAS-C Bi-directional valve with flow-selectable feature Installation of valve The valve can be installed horizontally or vertically in either the flow or return pipe. A built-in flow direction selection feature can be used to eliminate the risk of water hammer. If water hammer is encountered, turn the setting ring to the other setting. To change the flow direction, simply turn the setting ring without removing the valve. Open one valve and determine flow direction by observing which pipe heats first. Close all radiator valves by turning the valve cover cap clockwise. Remove cap and turn setting ring according to the drawings.
  • Page 2: Installation guide Fitting the sensor The desired room temperature is set by turning the head. The thermostat opens and closes as determined by the temperature around it. The sensor must never be hidden behind thick curtains, furniture, etc. Positive shut-off feature allows for complete water flow shut off. Set desired room temperature. What is a thermostatic radiator valve (TRV)? TRVs sense the air temperature around them and regulate the flow of water through the radiator. Turning a TRV to a higher setting will not make the room heat up any faster. TRVs need a free flow of air to sense the temperature.