Danfoss 013R9355 Radiator Thermostat Instructions
INSTRUCTION
Radiator Thermostat RAS-C2 Combi
BI-DIRECTIONAL VALVE WITH FLOW-SELECTABLE FEATURE
Installation of valve
Troubleshooting
The valve is a bi-directional valve * and can be installed
horizontally or vertically in either the flow or return
pipe.
A built in flow direction selection feature can be used to
eliminate the risk of water hammer.
In the unlikely event of water hammer being encountered
turn the setting ring (see diagram 4) to the other setting.
Alternatively if commissioning the whole system,
establish the flow direction through each valve using
the diagrams below.
If the flow direction needs to be changed there is
no need to remove the valve, simply turn the setting
ring.
2
3
1
Start boiler/heating.
Open one valve and determine
flow direction. Which pipe heats
first?
Close all radiator valves by turning
the valve cover cap clockwise.
Leave system to cool.
Keymark reference: This package contains sensor 013G6040, valve 013G6281 (15mm) or valve 013G6283 (8/10 mm)
Setting ring
4
Remove cap and turn setting
ring according to the drawings -
the setting ring is turned by hand
only.
5
Repeat step 3 and 4 until all valves have
been set correctly. Sensor may now be fit-
ted or the valve cap temporarily refitted.
VISXM302/Danfoss DKCD 05/2011
* Maximum pressure drop should not exceed 0.45 bar
| General | Details |
|---|---|
| Name | Danfoss 013R9355 Radiator Thermostat Instructions |
| Make | Danfoss |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.08 MB |

Danfoss RET-MD Electronic Intelligent Dial Setting Thermostat Installation Guide
Danfoss VICUQ24M Icon Programmable II Room Thermostat Installation Guide

Danfoss MBC 8000, MBC 8100 Heavy Duty Thermostat Installation Guide

Danfoss UT 72-UT 73 Universal Thermostat Installation Guide

Danfoss ECtemp 530 Electronic Thermostat Installation Guide

Danfoss 014G0251 Eco Radiator Thermostat User Guide

Danfoss 014G0013 Z Wave Radiator Thermostat Installation Guide

Danfoss RET230P Electronic Thermostat Instruction Manual

Danfoss TP7000 Range Electronic 7 Day Programmable Room Thermostat Installation Guide

Danfoss RET1000 Series Electronic Thermostat User Guide

Danfoss 013R9355 Radiator Thermostat Instructions Overview
Summary of Contents
- Page 1: Radiator thermostat RAS-C Bi-directional valve with flow-selectable feature Installation of valve The valve can be installed horizontally or vertically in either the flow or return pipe. A built-in flow direction selection feature can be used to eliminate the risk of water hammer. If water hammer is encountered, turn the setting ring to the other setting. To change the flow direction, simply turn the setting ring without removing the valve. Open one valve and determine flow direction by observing which pipe heats first. Close all radiator valves by turning the valve cover cap clockwise. Remove cap and turn setting ring according to the drawings.
- Page 2: Installation guide Fitting the sensor The desired room temperature is set by turning the head. The thermostat opens and closes as determined by the temperature around it. The sensor must never be hidden behind thick curtains, furniture, etc. Positive shut-off feature allows for complete water flow shut off. Set desired room temperature. What is a thermostatic radiator valve (TRV)? TRVs sense the air temperature around them and regulate the flow of water through the radiator. Turning a TRV to a higher setting will not make the room heat up any faster. TRVs need a free flow of air to sense the temperature.