User’s Manual
І. Application
Programmable Differential Thermostat DT-3.1.1 is used for domestic hot water preparation in water heaters, where the
heating energy is provided in combined way, by solar panels (fireplace) and electrical heating elements. It is designed to control
the circulation pump operation, installed in the water circuit between the solar panels (fireplace) and the water heater
serpentine, thus regulating the heat exchanging between them.
II. Operation
The thermostat has two temperature sensors mounted respectively in the boiler and solar panels. During an operation the
thermostat monitors the following parameters:
2.1. ∆Т, ∆t – adjusted and current (real) difference between the water heater and solar panel temperatures. ∆Т can be
adjusted in the range of 2 up to 20°С. The default setting is 10°С
2.2. Wb – adjusted temperature level of the water heater to which it can be heated from the solar panels. The
temperature can be adjusted in the range between 30 and 90°С. The default setting is 60°С.
2.3. Tbmax – maximum allowed water heater temperature. It can be adjusted in the range between 80 and 100 °С. The
default setting is 95°С.
2.4. Tpmin – minimum temperature level of the solar panel. It can be adjusted in the range between 20 and 50 °С. The
default setting is 40°С.
2.5. Tpmax – maximum allowed temperature of the solar panel. It can be adjusted in the range between 80 and 110°С.
The default setting is 105°С.
2.6. Tpdefrost – defrost temperature level of the solar panel. It can be fixed in the range between -20 up to 10°С. The
default setting is “- -“, without defrosting.
2.7. H (Thset) - set temperature in the boiler, up to which it can be heated by electric heaters. It is set in the range from
5 to Wb-5 ° С. Default setting 45 ° C;
2.8. Pr - priority of heating the boiler by electric heaters.
2.9. tc - delayed cooling time of the boiler. It is set in the range from 0 to 5 hours. Default setting 0.
2.10. Tbmin – minimum water temperature level in the water heater. It cannot be adjusted. The default setting is 20°С
Differential Thermostat DT-3.1.1 operation depends on the temperature sensor states, as follows:
А) Normal operation
- In case of a positive temperature difference Δt between the solar panel (stove) and the water tank, greater than the set
ΔT of 3 ° C, the pump starts operation, thus heating the tank from the panel.
A timer is being switched on when ∆t gets equal to ∆T, as from this moment the controller counts 10 minutes of
circulation pump operation. That time can vary within above range of 10 minutes as decreasing the difference between ∆t and
∆T to 0 relates to less operation time of the pump, which the device count automatically. The pump operation stops if the
previous mentioned difference becomes 0 or less than 0.
- Heating the water tank under the above conditions can be made only until the temperature in the water tank gets equal
to the set one Wb, then the pump switches off, stopping the heating.
- If the above conditions are fulfilled, and the solar panel (stove) temperature falls below Tpmin, the pump stops, even
the following conditions ∆t>∆Т+3° and Тб< Wб are fulfilled.
- If the temperature of the panel falls below Tpdefrost the pump is being switched ON, although it has been switched off
because solar panel temperature is below Tpmin.
- Heating the boiler with electric heaters. By setting Pr, the heating priority is selected as follows:
0 - heating with electric heaters is disabled;
1 - heating with electric heaters is allowed when there are no conditions for heating from the panel, the temperature in
the boiler is lower than Thset and 10 minutes have passed during which the pump has not worked.
| General | Details |
|---|---|
| Name | INTIEL TD-3.1.1 Programmable Differential Thermostat User Manual |
| Make | INTIEL |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.17 MB |

INTIEL DT-3.1 Programmable Differential Thermostat User Manual

Intiel TD-3.1.1 Differential Manual: Questions and Answers
Intiel TD-3.1.1 Differential specifications
| Power supply | 230V / / 50-60Hz |
| Accuracy | 1° |
| Humidity | 0-80% |
Can the Intiel TD-3.1.1 Differential work with 110V power supply?
No. The unit requires 230V AC at 50-60Hz.
What does ∆T mean on the Intiel TD-3.1.1 Differential thermostat display?
The adjusted temperature difference between the water heater and solar panel. When the real difference exceeds this by 3°C, the pump starts. User Manual, p. 1
What do the temperature sensor abbreviations Wb, Tbmax and Tpmin stand for?
Wb is the target water heater temperature. Tbmax is its maximum allowed temperature. Tpmin is the minimum solar panel temperature.
| Abbreviation | Meaning |
|---|---|
| Wb | Target water heater temperature from solar panels |
| Tbmax | Maximum allowed water heater temperature |
| Tpmin | Minimum solar panel temperature |
What does the Pr setting control on the Intiel TD-3.1.1?
Priority determines whether electric heater heating is disabled or allowed only when solar heating conditions aren't met and 10 minutes pass without pump operation. User Manual, p. 1
Intiel TD-3.1.1 Differential compared with other room thermostats
| Specification | Intiel TD-3.1.1 Differential | BECA BHP-8000 | BECA BHT-6000 | BECA BHT-7000 |
|---|---|---|---|---|
| Power supply | 230V / / 50-60Hz | 24VDC/AC ±10% | 95 ~ 240 VAC, 50 ~ 60HZ | 95 ~240 VAC, 50~60Hz or 24V DC/AC, 50~60Hz |
| Accuracy | 1° | ±1℉ | ±0.5℃ or ±1℉ | ±1°C |
| Humidity | 0-80% | 5~95%RH(Non Condensing) | 5 ~ 95 % RH (Non Condensing) | 5 ~ 95 % RH (Non Condensing) |