BEFORE WIRING AND INSTALLING  
FEATURES  
On Appearance  
Fig 6  
Fig 5  
BHT-6000 Series Round Thermostat  
Press the icon  
User Guide  
2. 51mm round display area helps to protect your eyes.  
(2nd period).  
Press the icon  
and use the and arrows to set the temp.  
3. Installer must be a trained, experienced service technician.  
Repeat this process for periods 3 4and 5 6.  
Press the icon  
5. Amazing Silver Frame opens your modern life.  
6. The visiable thickenss above the wall is only 11mm.  
Saturday  
(6 will show along the top of the screen).  
Repeat the above process to set the period and temp. and Sunday  
schedule.  
CAUTION  
8. 86mm hidden box and european 60mm round box is suitable.  
9. White, black or gold housing creates your colorful life.  
HOME SCREEN QUICK REFERENCE  
①Monday To Sunday  
②Room Temp.  
Press  
once more to confirm and exit.  
Electrical Shock or Equipment Damage Hazard. Can shock  
individuals or short equipment circuitry.  
⑭
⑮
Set Temp.  
③
④
Floor Temp.  
WEEKDAY (MONDAY – FRIDAY)  
(1 2 3 4 5 shows on screen)  
WEEKEND (SATURDAY)  
(6 shows on screen)  
WEEKEND (SUNDAY)  
(7 shows on screen)  
Time display  
⑤Wifi  
2. 0.5°C Accuracy keeps temperature within the level you set.  
3. Data memory when power is off.  
4. 5+2 six periods programmable maximize comfort and economy.  
5. Creat thermostat group to Centralized control  
6. Interated with Amazon Echo ,Google Home , Tmall Genie .I
Clock  
⑥
⑦
⑧
⑨
WIRING  
TIME  
TEMPERATURE  
。
TIME  
TEMPERATURE  
。
TIME  
TEMPERATURE  
。
Manual  
GA  
06:00  
20 C  
。
Period 1  
Period 2  
20 C  
。
06:00  
08:00  
11:30  
06:00  
08:00  
11:30  
13:30  
20 C  
。
①
②
20 C  
。
08:00  
11:30  
15 C  
。
20 C  
。
⑬
Time Display  
AC95~240V  
NTC  
20 C  
。
Period 3  
Period 4  
Period 5  
15 C  
。
20 C  
。
N
L
⑲
⑫
Timing On/Off  
⑩
⑪
⑫
⑬
IP20  
13:30  
17:00  
20 C  
。
13:30  
17:00  
15 C  
。
20 C  
。
M
Humidity  
③
④
⑤
For Water Heating/Boiler/Electric Heating  
⑪
⑱
20 C  
22 C  
20 C  
17:00  
22:00  
Close  
Open  
8. No limit to add rooms and support Smart Scene.  
5
6
℃ or ℉  
GB  
。
1
3
4
2
。
。
Period 6  
86mm  
60±2mm  
22:00  
15 C  
Period 1 to Period 6  
15 C  
15 C  
22:00  
WIFI TYPE  
A (RED)  
B (WHITE)  
DIMENSION  
AC95~240V  
⑭Room Temp. Display  
⑥
⑦
A separate schedule may be set for weekdays (Mon – Fri) and for  
weekends (Sat or Sun).  
7. Checking the Temperature of Floor Sensor  
N
L
NTC  
⑮
IP20  
50mm  
LOAD  
Welcome  
Thank you for your purchase.  
⑯
Modbus  
⑰
⑩
⑰
N1  
L1  
5
6
1
3
4
GC  
2
Press and hold the  
floor sensor.  
8. Return To Factory Default  
arrow for 5 seconds to display the temp. of  
⑱
A (RED)  
B (WHITE)  
⑲Mode  
⑯
Your new thermostat will provide uniform and comfortable  
temperature control throughout every room in your property. We  
bring together technology,  
materials to provide you with a safe, reliable product combined with  
sleek, contemporary design.  
AC95~240V  
⑳Power On/off  
N
L
NTC  
IP20  
Dry Contact  
Modbus  
⑧
⑨
Press the Reatore Manufacturer Defaults, you can reset thermostat.  
Steps:Open your app -go into your room - click menu on the top  
right corner - move to the end - Press Restore Manufacturer Defaults.  
During Power Off  
5
6
OPERATION  
During Power On  
1
3
4
2
Note:  
GA  
50mm  
A (RED)  
B (WHITE)  
programming manual for comprehensive  
thermostat. Please also  
ensure a suitably qualified person installs your thermostat and  
Press  
to turn the thermostat on/off.  
1. Power On/off:  
2. Manual & Programmable  
Touch M (mode) to change between manual mode and programme  
Modbus  
GC is for water/gas boiler;  
When power is off, press and hold M  
Then press M to scroll through  
INSTALLATION  
90mm  
In programmable mode, the period icon will show in the right side.  
available  
In the box you will find  
Back  
Code  
Func on  
Se ng and op ons  
Default  
could not be  
adjusted.If the user want to change, please go to manual mode or  
programmable mode.  
Step 1. Keep power off. See Fig 1.  
2pc  
Screws  
Floor Sensor (2.5m) 1pc  
1pc  
1pc  
1pc  
Thermostat  
User Guide  
Front  
Temperature  
compensa on  
24mm  
1
2
-7 to + 9℃ (for internal sensor)  
-1  
Unit: mm  
Fig 1  
Fig 2  
Side  
QC Passed  
Deadzone  
Temperature  
In the mode of manual, press  
to set the desired temperature.  
1 ~ 5℃  
1
C
to set minute, hour and weekday (1 = Monday,  
00: All bu ons are locked except power bu on.  
01: All bu ons are locked.  
3
Bu on locking  
Sensor types  
01  
TECHNICAL DATA  
Power Supply: 95 ~ 240 VAC, 50 ~ 60HZ  
Current Load:3A(  
Touch the icon  
ABOUT YOUR THERMOSTATS  
2 = Tuesday etc.) by using the  
confirm and exit.  
5. Locking your Thermostat  
arrows. Press  
once more to  
In:Internal Sensor(to control the temp. )  
Ou: Only external sensor  
(to control the temp. )  
BHT- 6000 range has been developed to control electric  
AL  
AL:Internal/ External Sensor(Internal sensor to  
control the temp., external sensor to limi he  
temp.)  
4
Press and hold the  
for 5 seconds to lock/unlock your thermostat  
lock or half lock.  
Sensor: NTC3950, 10K  
Accuracy: ±0.5℃ or ±1℉  
Set Temp. Range: 5 -35℃  
Dispaly Temp. Range: 5 ~ 99℃  
Ambient Temp.: 0 ~ 45 ℃  
Ambient Humidity: 5 ~ 95 % RH (Non Condensing)  
Storage Temp.: -5 ~ 45 ℃  
Step 3. Connect power supply, load into the appropriate terminals.  
(see “Wiring your thermostat” for details and Fig 3).  
5
6
Min. Set Temp.  
Max. Set Temp.  
05  
35  
5-15℃  
MODEL DEFINITION  
P
S
15-45℃  
00:Display both se emp. and room temp.  
01:Display se emp. only  
the box. See Fig 4.  
accept the program schedule made via the APP on your device (see  
7
00  
00  
45  
Display Mode  
Fig 3  
Fig 4  
GC: Water/Gas Boiler, 3A  
L: Backlight  
P: Weekly Programmable  
Low temperature  
protec on se ng.  
0-10℃  
your thermostat (NOT via your smartphone/tablet) simply follow the  
as below:  
8
9
High temperature  
protec on se ng.  
25-70℃  
Timing Error: < 1%  
Shell Material: PC +ABS ( Fireproof)  
W: Wifi  
S2: Both internal sensor and floor external sensor  
For example: 6000 GCLW  
00: Non-energy saving Mode  
01: Energy saving mode  
A
0
Economy Mode  
Economy Temp.  
Standby Brightness  
thermostat and smartphone/tablet.  
Wire Terminals: Wire 2 x 1.5 mm2 or 1 x 2.5 mm2  
20  
0-30 ℃  
20  
04  
B
C
Touch  
M
to change between manual mode and programme  
3-99  
In programme mode, touch and hold the icon  
GeneralDetails
NameBeca BHT-6000 Series Round Thermostat User Guide
MakeBECA
LanguageEnglish
FiletypePDF (Download)
File size2.24 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
Beca BHT-9000 Thermostat User Guide
Beca BHT-9000 Thermostat User Guide
beca BAC-005 Series Thermostat User Guide
beca BAC-005 Series Thermostat User Guide
Beca BAC-1000 Series WiFi Thermostat User Guide
Beca BAC-1000 Series WiFi Thermostat User Guide
Beca BHT-002 Electric Heating Wifi Thermostat User Guide
Beca BHT-002 Electric Heating Wifi Thermostat User Guide
Beca BHT-008 Heating Thermostat User Guide
Beca BHT-008 Heating Thermostat User Guide
Beca BHT-7000 Smart Knob Thermostat User Manual
Beca BHT-7000 Smart Knob Thermostat User Manual
Beca BAC-006 Zigbee Thermostat User Guide
Beca BAC-006 Zigbee Thermostat User Guide
Beca BHT-006 Series Thermostat User Manual
Beca BHT-006 Series Thermostat User Manual
Beca BHP-8000 C Room Thermostat User Guide
Beca BHP-8000 C Room Thermostat User Guide
beca BAC-003 Series WiFi Thermostat Fan Coil User Guide
beca BAC-003 Series WiFi Thermostat Fan Coil User Guide

Beca BHT-6000 Series Round Thermostat User Guide
Get the free PDF manual for the Beca BHT-6000 Series Round Thermostat User Guide and access setup steps, usage instructions, and troubleshooting tips. 👉 View online or download now to keep your thermostat running smoothly!

BECA BHT-6000 Manual: Questions and Answers

BECA BHT-6000 specifications

Power supply95 ~ 240 VAC, 50 ~ 60HZ
Maximum load3A
Setpoint range5 -35℃
Accuracy±0.5℃ or ±1℉
SensorNTC3950, 10K
Operating temperature0 ~ 45 ℃
Storage temperature-5 ~ 45 ℃
Humidity5 ~ 95 % RH (Non Condensing)

Full specifications, page 1

What is the difference between manual mode and programmable mode on the BECA BHT-6000?

ModeHow it works
ManualPress to set the desired temperature directly
ProgrammablePeriod icon shows on the right side; 5+2 six periods can be scheduled separately for weekdays and weekends

User Guide, p. 1

Can I check the temperature reading from the floor sensor on the BECA BHT-6000?

Press and hold the down arrow for 5 seconds to display the floor sensor temperature. User Guide, p. 1

BECA BHT-6000 compared with other BECA thermostats

SpecificationBECA BHT-6000BECA BAC-7000BECA BHP-8000BECA BHT-7000
Power supply95 ~ 240 VAC, 50 ~ 60HZ95 ~240 VAC, 50~60Hz or 24V DC/AC, 50~60Hz24VDC/AC ±10%95 ~240 VAC, 50~60Hz or 24V DC/AC, 50~60Hz
Accuracy±0.5℃ or ±1℉±0.5 ℃±1℉±1°C
SensorNTC3950, 10KNTC3950, 10KNTC3950, 10KNTC3950, 10K
Operating temperature0 ~ 45 ℃0~45 ℃32~113℉(0~45℃)0~ 45°C
Storage temperature-5 ~ 45 ℃0~ 45℃23~113℉ (-5~45℃)-10~ 45°C
Humidity5 ~ 95 % RH (Non Condensing)5 ~ 95 % RH (Non Condensing)5~95%RH(Non Condensing)5 ~ 95 % RH (Non Condensing)