І. Application  
Programmable Differential Thermostat DT-3.1 is used for domestic hot water preparation in water heaters, where the  
heating energy is provided in combined way, by solar panels (fireplace) and electrical heating elements. It is designed to control  
the circulation pump operation, installed in the water circuit between the solar panels (fireplace) and the water heater  
serpentine, this regulating the heat exchanging between them.  
II. Operation  
The thermostat has two temperature sensors mounted respectively in the boiler and solar panels. During an operation the  
thermostat monitors the following parameters:  
2.1. ∆Т, ∆t – adjusted and current (real) difference between the water heater and solar panel temperatures. ∆Т can be  
adjusted in the range of 2 up to 20°С. The default setting is 10°С  
2.2. Wb – adjusted temperature level of the water heater to which it can be heated from the solar panels. The  
temperature can be adjusted in the range between 30 and 90°С. The default setting is 60°С.  
2.3. Tbmax – maximum allowed water heater temperature. It can be adjusted in the range between 80 and 100 °С. The  
default setting is 95°С.  
2.4. Tpmin – minimum temperature level of the solar panel. It can be adjusted in the range between 20 and 50 °С. The  
default setting is 40°С.  
2.5. Tpmax – maximum allowed temperature of the solar panel. It can be adjusted in the range between 80 and 110°С.  
The default setting is 105°С.  
2.6. Tpdefrost – defrost temperature level of the solar panel. It can be fixed in the range between -20 up to 10°С. The  
default setting is “- -“, without defrosting.  
2.7. Tbmin – minimum water temperature level in the water heater. It cannot be adjusted. The default setting is 20°С  
Differential Thermostat DT-3.1 operation depends on the temperature sensor states, as follows:  
А) Normal operation  
- In case of a positive temperature difference Δt between the solar panel (stove) and the water tank, greater than the set  
ΔT of 3 ° C, the pump starts operation, thus heating the tank from the panel.  
A timer is being switched on when ∆t gets equal to ∆T, as from this moment the controller counts 10 minutes of  
circulation pump operation. That time can vary within above range of 10 minutes as decreasing the difference between ∆t and  
∆T to 0 relates to less operation time of the pump, which the device count automatically. The pump operation stops if the  
previous mentioned difference becomes 0 or less than 0.  
- Heating the water tank under the above conditions can be made only until the temperature in the water tank gets equal  
to the set one Wb, then the pump switches off, stopping the heating.  
- If the above conditions are fulfilled, and the solar panel (stove) temperature falls below Tpmin, the pump stops, even  
the following conditions ∆t>∆Т+3° and Тб< Wб are fulfilled.  
- If the temperature of the panel falls below Tpdefrost the pump is being switched ON, although it has been switched off  
because solar panel temperature is below Tpmin.  
В) VACATION Mode - The current mode is useful in case of not using the water tank for a long time. In case of the mode  
activation the adjusted temperature is being automatically set to 40 °С, as the heating elements switching on is not allowed. The  
pump is being switched on when it is necessary in order to prevent the overheating of the tank or the solar panel. The mode can  
be activated by means of pressing “PROGRAM” button for 3 seconds, as after its releasing on the display appears ON/OFF  
indication. When activated, the indication flashes “HOL”.  
В) Emergency operation  
- If during water heater warming the solar panel (stove) temperature exceeds Tpmax , the circulation pump will be  
switched on by force in order to provide the solar panel cooling. The previous mentions will be done despite of the water heater  
temperature can exceed Wb.  
GeneralDetails
NameINTIEL DT-3.1 Programmable Differential Thermostat User Manual
MakeINTIEL
LanguageEnglish
FiletypePDF (Download)
File size0.18 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
INTIEL TD-3.1.1 Programmable Differential Thermostat User Manual
INTIEL TD-3.1.1 Programmable Differential Thermostat User Manual

INTIEL DT-3.1 Programmable Differential Thermostat User Manual
Get the free PDF manual for the INTIEL DT-3.1 Programmable Differential Thermostat User Manual and access setup steps, usage instructions, and troubleshooting tips. 👉 View online or download now to keep your thermostat running smoothly!

Intiel DT-3.1 Differential Manual: Questions and Answers

Intiel DT-3.1 Differential specifications

Power supply230V / / 50-60Hz
Accuracy1°
Humidity0-80%

Full specifications, page 5

What does HOL mean on Intiel DT-3.1 display?

Flashing HOL indicates VACATION Mode is active. In this mode the thermostat sets temperature to 40°С and prevents electrical heating elements from turning on. User Manual, p. 1

What happens if solar panel temperature exceeds maximum on Intiel DT-3.1 Differential?

The pump forces on to cool the solar panel, regardless of whether water tank temperature has reached the target setting Wb. User Manual, p. 1

How long is the warranty period on the Intiel DT-3.1?

24 months from purchase or installation, but not more than 28 months after the production date. User Manual, p. 5

Intiel DT-3.1 Differential compared with other room thermostats

SpecificationIntiel DT-3.1 DifferentialBECA BHP-8000BECA BHT-6000BECA BHT-7000
Power supply230V / / 50-60Hz24VDC/AC ±10%95 ~ 240 VAC, 50 ~ 60HZ95 ~240 VAC, 50~60Hz or 24V DC/AC, 50~60Hz
Accuracy1°±1℉±0.5℃ or ±1℉±1°C
Humidity0-80%5~95%RH(Non Condensing)5 ~ 95 % RH (Non Condensing)5 ~ 95 % RH (Non Condensing)

More Intiel thermostat manuals