Home > INTIEL > INTIEL TD-3.1.1 Programmable Differential Thermostat User Manual

INTIEL TD-3.1.1 Programmable Differential Thermostat User Manual

2 - heating with electric heaters is allowed until the Thset is reached without taking into account the condition of the  
pump.  
Default setting - 1.  
Heating with electric heaters is prohibited when the "vacation" mode is activated.  
В) VACATION Mode - The current mode is useful in case of not using the water tank for a long time. In case of the  
mode activation the adjusted temperature is being automatically set to 40 °С, as the heating elements switching on is not  
allowed. The pump is being switched on when it is necessary in order to prevent the overheating of the tank or the solar  
panel. The mode can be activated by means of pressing “PROGRAM” button for 3 seconds, as after its releasing on the  
display appears ON/OFF indication. “HoL” flashes on the display.  
C) Emergency operation  
- If during water heater warming the solar panel (stove) temperature exceeds Tpmax , the circulation pump will be  
switched on by force in order to provide the solar panel cooling. The previous mentions will be done despite of the water heater  
temperature can exceed Wb.  
- If at the previous mentioned emergency case, the water heater temperature reaches its maximum allowed temperature  
level Tbmax, the circulation pump will be stopped despite of this state can causes overheating of the solar panel. In this way the  
temperature at the water heater as an overheating protection has a higher priority compare to the temperature of the solar panel  
(stove).  
- When the temperature Tb is above the set Wb and is above the temperature of the panel Tp, in order to avoid  
overheating of the boiler, if there is no hot water consumption the pump is switched on until the temperature of the boiler Tb  
drops to the set Wb. This cooling can be delayed for 0 to 5 hours. Sets via parameter tc (default setting is 0). When combined  
heating with electric heaters is used, the settings for the electric heaters must be lower than Wb.  
D) Water tank and solar panel protection  
When the water tank temperature Tb is above the assigned one Wb and in the same time is grater than the solar panel  
temperature, in terms of preventing water tank overheating the circulation pump will be switched on. Its operation goes on  
until the water tank temperature Tb is being decreased to the assigned one Wb. In this case the water tank gives the excessive  
heat, as it cool itself through the solar panel. When a combine heating with electrical heating elements is being used, then the  
assignation of the of the electrical part is to be a little bit lower than Wb.  
ІIІ. Front panel indications  
On the front panel are located all elements for control and programming. These are three digital display, ten light indications  
and two buttons, “SELECT” and “PROGRAM”. The front panel vision is shown on Figure 1 bellow.  
Fig.1  
Indications on the digital display  
1
2
3
4
5
6
7
8
9
Tb – shows the water heater temperature  
Tp – shows solar panel temperature  
∆Т – shows the adjusted temperature difference between the solar panel and the water heater  
Wb – shows the water heater temperature level which has to be kept  
Tbmax - shows the maximum allowed water heater temperature  
Tpmin – shows the fixed minimum temperature level of the solar panel  
Tpmax – shows the adjusted maximum temperature level of the solar panel  
Tpdefrost – shows the adjusted temperature level for solar panel defrosting  
Pump – shows the circulation pump operation  
10 Heater - Electrical heater is ON  
11 Alarm – shows emergency operation  
2
GeneralDetails
NameINTIEL TD-3.1.1 Programmable Differential Thermostat User Manual
MakeINTIEL
LanguageEnglish
FiletypePDF (Download)
File size0.17 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
INTIEL DT-3.1 Programmable Differential Thermostat User Manual
INTIEL DT-3.1 Programmable Differential Thermostat User Manual

INTIEL TD-3.1.1 Programmable Differential Thermostat User Manual