Home > SALUS > SALUS RT520 Radiator Thermostat User Guide

SALUS RT520 Radiator Thermostat User Guide

Programming - Automatic Mode  
The schedule has 6 time intervals for which different temperatures can be adjusted. You can set 2,  
3 or up to 6 temperatures per day. You must define all time periods. Here is an example of setting a  
certain time with a certain temperature.  
Landlord Settings  
Administrator settings is a function protected by a PIN code that allows the administrator to set a service  
reminder on the regulator that will warn the tenant about the upcoming boiler inspection.  
RT520TX Thermostat Pairing with the Receiver  
When the OPTIMUM START function is active, the thermostat sends a heating signal to the heat source  
beforehand so that the preset temperature in the room is reached at the set time in the schedule.  
If you are using the RT520RF pack, the pairing between the thermostat and the receiver is already  
done. During the pairing process, please make sure the thermostat and the receiver are at least 1  
meter from each other.  
When the OPTIMUM STOP function is active, the thermostat, taking into account the inertia of the system,  
switches off the heat source earlier, keeping the temperature set in the schedule.  
1
2
3
Exemplary operation of the thermostat according to the schedule 6:00 - 23:00 21°C & 23:00 - 6:00 19°C:  
If you bought the RT520TX and RXRT520 separately or if you want to re-pair thermostat with the  
receiver, make sure that the device is disconnected from the power supply and the switches on the  
receiver have been set to AUTO and ON. Then connect the receiver to the power supply and wait for  
the red LED to light steadily. Then switch to the OFF position and again to ON position quickly. The red  
flashing LED will confirm entering the pairing mode.  
1
2
3A  
TEMP.  
SETPOINT TEMP. 21°C  
C
D
21°C  
20°C  
19°C  
SETPOINT TEMP. 19°C  
ROOM TEMPERATURE  
SETPOINT TEMP. 19°C  
3
1
2
A
B
0:00 1:00 2:00 3:00 4:00 5:00 6:00 7:00 8:00...  
...12:00...  
...17:00 18:00 19:00 20:00 21:00 22:00 23:00 TIME  
Using UP or DOWN, enter the  
PIN code. Press OK to confirm  
each numeral. PLEASE NOTE:  
The first code entry is also the  
setting of a new PIN code which  
will be necessary to enter the  
Administrator mode.  
Using UP or DOWN, navigate to  
Landlord submenu  
and press SELECT.  
Press  
button.  
A - OPTIMUM START ON (earlier it turns on the heating - it goes towards the set 21°C)  
B - OPTIMUM START OFF (turns on heating according to a schedule)  
C - OPTIMUM STOP ON (earlier it turns off the heating - it goes to the set 19°C)  
D - OPTIMUM STOP OFF (turns off heating according to a schedule)  
Press OK.  
Using UP or DOWN select  
program type between: 5 (Mon-Fri)...  
Press  
button.  
3B  
4
5
4
5
6
4
5
6
16A  
16B  
16  
OR  
Press OK button.  
Using UP or DOWN, select ON and  
press OK.  
Using UP or DOWN, select the  
number of days after which the  
boiler will be inspected and then  
press OK.  
... + 2 (Sat + Sun), which is a  
separate schedule for working  
days and weekend.  
All days (one schedule for  
whole week).  
Individually (a separate schedule  
for everyone day of the week).  
Press OK button.  
Use the UP and DOWN buttons and confirm with OK.  
Press MENU.  
Using UP or DOWN, navigate to  
Pairing submenu and press SELECT.  
Using UP or DOWN, select PAIR  
and press SELECT.  
7
8
9
7
8
9
17  
17  
6
7
8
or  
or  
ON  
OFF  
AUTO  
MANUAL  
Using the UP and DOWN buttons,  
Using UP or DOWN select the  
Press OK button.  
select the day on which a reminder set temperature of the blocked  
about the upcoming boiler thermostat and then press OK.  
maintenance will appear.  
Using UP or DOWN, select ON or  
OFF and confirm with OK.  
Using UP or DOWN, select ON or  
OFF and confirm with OK.  
The pairing process takes  
up to 10 minutes.  
Once devices are successfully  
paired, LED on the receiver  
will go solid red.  
After all, thermostat will go back  
to the main screen.  
Using UP or DOWN, set the hour  
and then press OK.  
Using UP or DOWN, set the  
minutes and then press OK.  
Use the UP or DOWN button to set  
the temperature and then  
press OK.  
10  
11  
12  
Use the  
button to confirm  
18  
and exit the thermostat  
options. Then, using the UP  
and DOWN buttons, navigate  
to the other administrator  
settings options (see the next  
steps).REMEMBER! Save the  
PIN code, thanks to which you  
can enter Administrator mode  
without troubles.  
Test the Pairing Process  
Repeat the process for all time periods.  
1
2
3
If you only need to change the set temperature twice a day, below is how to cancel one or more  
intervals.  
Using UP or DOWN enter the  
phone number. Press OK to  
confirm each numeral.  
Using the UP and DOWN buttons,  
select the next setting option.  
The thermostat will go to  
main screen.  
13  
14  
15  
Switching between manual mode and automatic mode  
Press MENU.  
Using UP or DOWN, navigate to  
Pairing submenu and press SELECT.  
Using UP or DOWN, select  
TEST and press SELECT.  
TO SWITCH FROM AUTOMATIC TO MANUAL MODE:  
4
5
Press OK button.  
Using the UP and DOWN buttons,  
select the maximum value of the  
set temperature. Confirm with  
the OK button.  
Using the UP and DOWN buttons,  
select the minimum value of the  
set temperature. Confirm with the  
OK button.  
In the manual mode, the  
user can set the desired  
temperature that the  
thermostat will maintain.  
22  
Press the UP button several times on  
the selected interval that you want  
to delete (until the line appears on  
the screen).  
When the lines are displayed,  
press OK to confirm deletion of the  
selected interval.  
ON  
OFF  
AUTO  
MANUAL  
17  
18  
1
The icon will appear on the display  
hand, which means the thermostat is in  
manual mode.  
The testing process takes  
up to 10 minutes.  
The red LED and the green  
LED on the receiver  
will begin to flash.  
P
r
e
s
s
.
TIME:  
06.00  
10.00  
12.00  
14.00  
18.00  
21.00  
6 TEMP/DAY  
21 °C  
2 TEMP/DAY  
21 °C  
TO SWITCH FROM MANUAL TO AUTOMATIC MODE:  
Factory Reset  
Here are some examples of weekly  
schedules (for 6 and 2 temperature  
changes during the day).  
14 °C  
-
Press OK to configure the receiver  
(RECEIVE). When the parameter  
is set to “MANUAL ON”, the  
receiver’s “AUTO-MANUAL” switch  
is active (not locked). By setting  
the switch in the receiver to the  
“AUTO” position, the receiver  
responds to the regulator’s signals.  
Setting “MANUAL” causes that the  
operation of the receiver depends  
only on the position of the upper  
switch on the receiver (ON-OFF).  
When the thermostat parameter is  
set to “OFF MANUAL”, the switch  
on the receiver “AUTO-MANUAL”  
is disabled (disabled). The user  
cannot enable manual mode on  
the receiver. The receiver will  
always react to signals sent by the  
thermostat.  
1
2
21 °C  
-
14 °C  
-
In automatic mode, the  
thermostat works according  
to a programmed schedule.  
19  
21 °C  
-
14 °C  
14 °C  
To reset the thermostat, press MENU,  
DOWN and BOOST simultaneously  
for 5 seconds.  
The device will be reset and will  
start up automatically.  
The hand icon will disappear from  
the display which means the  
thermostat will return to automatic  
mode.  
Press and hold  
for 3 seconds.  
button  
Thermostat will return to SERVICE.  
To return to the main screen, wait 10  
seconds or hold the button  
Landlord settings will not be reset. Devices are still paired together.  
.
GeneralDetails
NameSALUS RT520 Radiator Thermostat User Guide
MakeSALUS
LanguageEnglish
FiletypePDF (Download)
File size0.92 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
SALUS IT800 WIFI Smart Thermostat Installation Guide
SALUS IT800 WIFI Smart Thermostat Installation Guide
SALUS 091FLRF Wireless Room Thermostat User Guide
SALUS 091FLRF Wireless Room Thermostat User Guide
SALUS Thermostat Sensor TS600 User Guide
SALUS Thermostat Sensor TS600 User Guide
SALUS Thermostat and Smart Plug Installation Guide
SALUS Thermostat and Smart Plug Installation Guide
SALUS Wired Thermostat Installation Guide
SALUS Wired Thermostat Installation Guide
SALUS Wired Digital Thermostat – Non-programmable HTRS230 User Manual
SALUS Wired Digital Thermostat – Non-programmable HTRS230 User Manual
SALUS Programmable Wired Thermostat VS30W/VS30B Installation Guide
SALUS Programmable Wired Thermostat VS30W/VS30B Installation Guide
SALUS RT310 Thermostat User Manual
SALUS RT310 Thermostat User Manual
SALUS Thermostat RT520 User Manual
SALUS Thermostat RT520 User Manual
SALUS BTR230 Room Thermostat User Guide
SALUS BTR230 Room Thermostat User Guide

SALUS RT520 Radiator Thermostat User Guide