Thermafloor TF1 Programmable Radiant Floor Thermostat User Manual

Operation:  
The thermostat controls your floor heating system based on built-in weekly program, running in  
4 or 2 stages per day, 7 days a week.  
The default weekly program parameters satisfies most usage scenarios, however you can also  
modify the weekly program parameters in the thermostat.  
When there is no one in the house, it is recommended to reduce the temperature set-point to  
save energy.  
USER MANUAL  
The thermostat also has built-in adaptive function. When this function is active, the thermostat  
heats or stops heating in advance of next stage to bring the room temperature to the set temp-  
erature of the next stage. Please note that after turning the Adaptive function ON, the thermostat  
will require a few days of normal operation to learn the time required to achieve the heating  
targets selected.  
Model: TF1  
Programmable Radiant Floor Thermostat  
Functions:  
Warnings:  
-Installation or replacement of this product should only be done by qualified personnel.  
-To avoid risk of electric shock, turn OFF the power source from the main service panel prior to  
installation of the thermostat.  
1
Mon 8:00  
-Keep thermostat air vents clean and free from obstructions.  
2
6
9
-Electric floor heating cable/mat must be in accordance with the thermostat supply voltage.  
-All wiring must conform to local as well as national electrical codes and ordinances.  
-Thermostat terminals are designed to handle a cross-section of wire measuring 12-22AWG.  
20.0°  
4
Auto Mode  
7
Installation:  
10  
21.0°  
1.Loosen the bottom screw by a Phillips screwdriver, then open the thermostat from the below  
as shown in figure 1:  
Wake : 21.0° 8:00  
5
Note: The bottom screw does not need to be removed to detach the faceplate.  
Mode  
Edit  
8
2. Wire the thermostat as shown in figure 2:  
3
L/N (Line): Connect incoming power supply to the terminal block.  
L1/N1 (Load): Connect the heating load wires to the terminal block.  
(Above wiring screws should be torqued between 0.7-1.0 N.m)  
Ensure the junction box is grounded, and attach the heating cable ground to this location.  
S1/COM/ : Connect the floor sensor.  
If a spare (redundant) probe has been installed in the floor, tape this to the other probe wire in the junction  
box, but ONLY CONNECT (1) SENSOR to the thermostat at any one time.  
1
3
5
7
9
2
4
Time  
LED  
Edit  
Heating  
3. Install the power base into the junction box and secure it using the supplied set screws as  
shown in Figure 3.  
(Screws should be torqued to approx 0.1-0.2 N.m)  
6
Temperature  
Mode  
Next Schedule  
8
Up and down regulation  
Mode state  
4. Install the thermostat faceplate on the power base; start by aligning the top of the units, then  
swing the faceplate down so it comes to rest on top of the power base, with the screw holes lined  
up; tighten the screw to secure the faceplate to the power-base.  
10  
Setting temperature  
5. Turn ON the thermostat and wait for the operating screen to be displayed.  
Temporary temperature setting  
Please press  
the button for temporary temperature setting  
Edit  
Mode  
》
02  
03  
01  
04  
Mode selection  
Menu  
Heating Schedule  
Energy Use  
POWER  
Auto Mode  
Manual Mode  
Away Mode  
FLOOR SENEOR  
User Settings  
Installer Settings  
N1  
N
L
L1  
COM S1  
》
POWER  
85V-265V  
50/60Hz  
FLOOR  
SENSOR  
OFF  
MAX LOAD: 16A  
IP 21  
Technical specification:  
Mode selection  
Supply voltage:  
Load:  
85-265 VAC 50/60 Hz  
max.16 A (resistive load)  
+5 to +40°C / +41 to +104°F  
+5 to +45°C / +41 to +113°F  
IP21  
This thermostat provides three operating modes:  
Setpoint range:  
Temperature range:  
Cover:  
Automatic mode:  
According to the weekly program, the thermostat automatically adjusts the set  
temperature operation.  
Floor sensor type:  
NTC B=3950 10k  
Manual mode:  
The thermostat runs continuously according to the set temperature.  
Away mode:  
Temp Tolerance:  
default 1°C /2°F  
This mode is used when you want to keep your room at a lower temperature when you  
are away for an extended period of time.This operating mode prevents damage to  
household/office equipment caused by sudden exposure to cold temperatures.  
The set-point temperature Range is set to maintain from 41°F to 59°F(5°C -15°C) in this  
mode.  
Dimensions (inches):  
OFF:  
Manually turn off all functions of the thermostat. When the device needs to be started,  
Press and hold the on/off button in screen for 3s.  
Edit selection  
GeneralDetails
NameThermafloor TF1 Programmable Radiant Floor Thermostat User Manual
MakeThermafloor
LanguageEnglish
FiletypePDF (Download)
File size0.35 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
Thermafloor HT1 Thermostat White App Electric Mat Thermostat User Guide
Thermafloor HT1 Thermostat White App Electric Mat Thermostat User Guide

Thermafloor TF1 Programmable Radiant Floor Thermostat User Manual
Get the free PDF manual for the Thermafloor TF1 Programmable Radiant Floor Thermostat User Manual and access setup steps, usage instructions, and troubleshooting tips. 👉 View online or download now to keep your thermostat running smoothly!

Thermafloor TF1 Radiant Manual: Questions and Answers

Can the Thermafloor TF1 Radiant thermostat work with floor heating systems that use 85-265 VAC power?

Yes. The thermostat is designed for supply voltages between 85-265 VAC at 50/60 Hz. User Manual, p. 1

How long does the Thermafloor TF1 need to learn heating patterns when adaptive function is turned on?

A few days of normal operation. The thermostat learns the time needed to reach your set temperature during this period. User Manual, p. 1

What do I connect to the S1 and COM terminals on the Thermafloor TF1 Radiant?

Connect the floor sensor to these terminals. If a redundant probe exists, tape it to the other probe wire but connect only one sensor to the thermostat. User Manual, p. 1

What does Away Mode on the Thermafloor TF1 mean and when should I use it?

Away Mode keeps your room at a reduced temperature when you're gone for extended periods, preventing damage from sudden cold exposure. The set-point stays between 5°C to 15°C (41°F to 59°F). User Manual, p. 1