Thermafloor TF1 Programmable Radiant Floor Thermostat User Manual
Operation:
The thermostat controls your floor heating system based on built-in weekly program, running in
4 or 2 stages per day, 7 days a week.
The default weekly program parameters satisfies most usage scenarios, however you can also
modify the weekly program parameters in the thermostat.
When there is no one in the house, it is recommended to reduce the temperature set-point to
save energy.
USER MANUAL
The thermostat also has built-in adaptive function. When this function is active, the thermostat
heats or stops heating in advance of next stage to bring the room temperature to the set temp-
erature of the next stage. Please note that after turning the Adaptive function ON, the thermostat
will require a few days of normal operation to learn the time required to achieve the heating
targets selected.
Model: TF1
Programmable Radiant Floor Thermostat
Functions:
Warnings:
-Installation or replacement of this product should only be done by qualified personnel.
-To avoid risk of electric shock, turn OFF the power source from the main service panel prior to
installation of the thermostat.
1
Mon 8:00
-Keep thermostat air vents clean and free from obstructions.
2
6
9
-Electric floor heating cable/mat must be in accordance with the thermostat supply voltage.
-All wiring must conform to local as well as national electrical codes and ordinances.
-Thermostat terminals are designed to handle a cross-section of wire measuring 12-22AWG.
20.0°
4
Auto Mode
7
Installation:
10
21.0°
1.Loosen the bottom screw by a Phillips screwdriver, then open the thermostat from the below
as shown in figure 1:
Wake : 21.0° 8:00
5
Note: The bottom screw does not need to be removed to detach the faceplate.
Mode
Edit
8
2. Wire the thermostat as shown in figure 2:
3
L/N (Line): Connect incoming power supply to the terminal block.
L1/N1 (Load): Connect the heating load wires to the terminal block.
(Above wiring screws should be torqued between 0.7-1.0 N.m)
Ensure the junction box is grounded, and attach the heating cable ground to this location.
S1/COM/ : Connect the floor sensor.
If a spare (redundant) probe has been installed in the floor, tape this to the other probe wire in the junction
box, but ONLY CONNECT (1) SENSOR to the thermostat at any one time.
1
3
5
7
9
2
4
Time
LED
Edit
Heating
3. Install the power base into the junction box and secure it using the supplied set screws as
shown in Figure 3.
(Screws should be torqued to approx 0.1-0.2 N.m)
6
Temperature
Mode
Next Schedule
8
Up and down regulation
Mode state
4. Install the thermostat faceplate on the power base; start by aligning the top of the units, then
swing the faceplate down so it comes to rest on top of the power base, with the screw holes lined
up; tighten the screw to secure the faceplate to the power-base.
10
Setting temperature
5. Turn ON the thermostat and wait for the operating screen to be displayed.
Temporary temperature setting
Please press
the button for temporary temperature setting
Edit
Mode
》
02
03
01
04
Mode selection
Menu
Heating Schedule
Energy Use
POWER
Auto Mode
Manual Mode
Away Mode
FLOOR SENEOR
User Settings
Installer Settings
N1
N
L
L1
COM S1
》
POWER
85V-265V
50/60Hz
FLOOR
SENSOR
OFF
MAX LOAD: 16A
IP 21
Technical specification:
Mode selection
Supply voltage:
Load:
85-265 VAC 50/60 Hz
max.16 A (resistive load)
+5 to +40°C / +41 to +104°F
+5 to +45°C / +41 to +113°F
IP21
This thermostat provides three operating modes:
Setpoint range:
Temperature range:
Cover:
Automatic mode:
According to the weekly program, the thermostat automatically adjusts the set
temperature operation.
Floor sensor type:
NTC B=3950 10k
Manual mode:
The thermostat runs continuously according to the set temperature.
Away mode:
Temp Tolerance:
default 1°C /2°F
This mode is used when you want to keep your room at a lower temperature when you
are away for an extended period of time.This operating mode prevents damage to
household/office equipment caused by sudden exposure to cold temperatures.
The set-point temperature Range is set to maintain from 41°F to 59°F(5°C -15°C) in this
mode.
Dimensions (inches):
OFF:
Manually turn off all functions of the thermostat. When the device needs to be started,
Press and hold the on/off button in screen for 3s.
Edit selection
| General | Details |
|---|---|
| Name | Thermafloor TF1 Programmable Radiant Floor Thermostat User Manual |
| Make | Thermafloor |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.35 MB |

Thermafloor HT1 Thermostat White App Electric Mat Thermostat User Guide

Thermafloor TF1 Programmable Radiant Floor Thermostat User Manual Overview
Summary of Contents
- Page 1: Operation of the thermostat controls the floor heating system based on a built-in weekly program. The default weekly program parameters satisfy most usage scenarios, but can be modified. It is recommended to reduce the temperature set-point when the house is unoccupied to save energy. The thermostat has a built-in adaptive function that learns the time required to achieve heating targets. Installation or replacement should only be done by qualified personnel to avoid risks. Keep thermostat air vents clean and free from obstructions. All wiring must conform to local and national electrical codes. The thermostat provides three operating modes: automatic, manual, and away mode. The away mode maintains a lower temperature to prevent damage from cold exposure. The device can be manually turned off by pressing and holding the on/off button for 3 seconds.
- Page 2: Heating schedule allows for programming across seven days with different parameters for weekdays and weekends. Troubleshooting includes checking power supply and ensuring proper connections to the thermostat. Common issues include no display, incorrect heating times, and floor sensor errors, with recommended solutions for each. Energy use tracking calculates heating time and energy consumption based on user settings. User settings allow for time and date adjustments, child lock activation, and unit selection between Fahrenheit and Celsius. Daylight saving time feature automatically adjusts the thermostat settings. Installer settings include adaptive function for temperature control and open window detection to save energy. Sensor applications cover room, floor, and combined protection with calibration options for accuracy. Floor protection is activated based on selected sensor types and temperature thresholds. Factory reset options are available to restore default settings, with a warning that personal settings will be lost.