Home > BEOK CONTROLS > BEOK CONTROLS BOT-R6W Boiler Thermostat User Guide
BEOK CONTROLS BOT-R6W Boiler Thermostat User Guide
| General | Details |
|---|---|
| Name | BEOK CONTROLS BOT-R6W Boiler Thermostat User Guide |
| Make | BEOK CONTROLS |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.66 MB |

BEOK CONTROLS TDR83 WiFi Heating Thermostat User Guide

BEOK CONTROLS TCR7 IPS Colorful LCD Screen Smart Thermostat Owner’s Manual

BEOK CONTROLS TDR89 Thermostat User Guide

BEOK CONTROLS BOT-R7X Wireless Gas Boiler Heating Thermostat Instructions

BEOK CONTROLS TCR8 IPS Colorful LCD Screen Smart Thermostat Owner’s Manual

BEOK CONTROLS TGW60 Touch Screen Boiler Thermostat User Guide

BEOK CONTROLS TGR86 WiFi Thermostat User Guide

BEOK CONTROLS BOT-323W Series Boiler Thermostat Instruction Manual

BEOK CONTROLS TDS72 Digital Screen Thermostat Instruction Manual

BEOK CONTROLS BOT-R6W Gas Boiler Thermostat Instruction Manual

BEOK CONTROLS BOT-R6W Boiler Thermostat User Guide Overview
Summary of Contents
- Page 1: This thermostat is suitable for boilers connected via dry contact.
- Page 2: Welcome Thank you for your trust and support! We have adopted advanced technology and perfect craftsmanship so that your new thermostat will provide you with a suitable temperature environment every day in the future. Working principle and main functions Intelligent digital thermostat is a temperature controller, which is suitable for boilers connected via dry contact. Main functions: weekly programming, frost protection function, temperature calibration, child lock and more. Model spec Current loading Controlled objects
- Page 3: Technical parameters include power supply options of 3 x 1.5 V alkaline AA battery or USB. The current load is specified as ≤ 3A with a self-consumption of <170μW. The external material is PC+ABS, which is flame retardant. The sensing element used is NTC. The set temperature range is adjustable from 5-60℃, with a default of ±1℃ and a temperature hysteresis of 0.5-10℃. The dimensions of the device are 86x86x28mm. The protection degree is rated as IP20.
- Page 4: Installation instruction includes steps for proper setup. Install expansion screw sleeve with a pitch of 59mm on the wall. Separate the upper cover and lower cover using a screwdriver. Ensure the wire passes through the back cover to the slot, leaving about 20cm of length. Fix the bottom shell to the wall and secure the wire. Cover the front shell on the bottom shell after installation.
- Page 5: Please read this manual carefully. Improper operation may damage the product or cause dangerous conditions. The installation personnel must be well-trained and experienced service technicians. After installation, please read this manual carefully and operate the product according to the instructions. Caution: Risk of electric shock. Wiring diagram.
- Page 6: Description of display & icon Time Week icon Battery level Heating icon Setting temp. Room temp. Mode icon
- Page 7: Operation instruction Power on/off: Press to turn on/off the thermostat. Set temperature: Press or to set the temperature. Set the clock: In power on state, press and hold the M key for 5 seconds to set the minute. Switch modes: In power on state, press M key to switch between Manual mode and Auto mode. Child lock function: Simultaneously press and hold the child lock to prevent children from misusing the device.
- Page 8: Frost protection function allows the thermostat to automatically turn on heating when the room temperature is below 5°C. This function can be turned on or off according to your needs. To set the Auto Mode, press and hold the M key for 5 seconds to enter programming mode. The display will show the position of the week for setting working and rest days. You can set the time and temperature for each time period. After setting the first time period, press the M key to enter the next time period setting. Press to save and exit once the setting is complete. In Auto Mode, the thermostat will run at the programmed temperature and time.
- Page 9: If the thermostat is manually adjusted during any period of operation in Auto Mode, it will temporarily run according to your manual settings and resume Auto/programming mode at the next programming time. The defaulted temperature of period 3 and period 4 is the same as period 2. Please change it according to the request. Do not set the last time point of each day beyond 23:59.
- Page 10: Advanced setting allows access to various configuration options. In power-off state, press the M key and another key to enter advanced option setting. Temperature calibration ranges from -9.9 to 9.9 °C. Temperature hysteresis can be set between 0.5 to 10 °C. Frost protection can be turned ON or OFF. Weekly programming mode can be set for different working and rest day configurations. Set temperature upper limit ranges from 15 to 95 °C. Long press a key to adjust the display to ---. There is an option to restore factory settings. Press the M key to enter the next option and save changes.