Low Temperature Protection Function
Advanced options enter the third option ON, the thermostat is in the
shutdown state, when the indoor temperature is lower than 5 degrees,
the thermostat automatically turns on heating. when the indoor
temperature rises to 5 degrees, the thermostat automatically turns
off heating.
Electrical Specification
Application
1. Temperature sensor: NTC
2. Temperature precision: +0.5°C
3. Self- consumed: < 170uW
4. Voltage: 3pcs 1.5V batteries
5. Load current: 3A(negative)
6. Protection grade: IP20
Intelligent digital thermostat is a temperature controller suitable
for floor heating systems. Through comparing ambient temperature
and set temperature, it controls the working state of the electric
valve of the floor heating system to adjust the ambient
temperature, which is comfort and energy saving.
Operating Instructions
Wiring Diagram
ON/OFF key: Press the ON/OFF key to turn on and off once;
N
L
M
K1
K2
NO
NC
Press shutdown again while closing all valves.
Mode switch key: In the power-on state, press
working mode. The LCD indicates the manual mode and the
display indicates the automatic mode.
to switch the
Regulation key: In the startup state, press the
button and the
temperature will flash, then rotate the outer frame to adjust the
temperature setting.
Clock adjustment: In the power on state, press and hold the
button for 5 seconds. After the icon flashes, rotate the outer frame to
Remark:
adjust. Press the
button to switch between time and week
button to save and exit.
N & L: 110~220Vac input
K1 & K2(dry contact): boiler / heater
adjustments, and press the
N & NO: normally close (NC) actuator
N & NC: normally open (NO) actuator
N & M: Valve
Lock key function: In the power on state, press and hold the
button for 5 seconds to enter the lock button state on the panel.
A lock icon appears at the bottom of the display screen, indicating
successful lock button locking
Notes: since some circuits of this product involve strong electricity,
which need to be installed by professionals.
| General | Details |
|---|---|
| Name | BEOK CONTROLS BOT-R7X Wireless Gas Boiler Heating Thermostat Instructions |
| Make | BEOK CONTROLS |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.22 MB |

BEOK CONTROLS TDR83 WiFi Heating Thermostat User Guide

BEOK CONTROLS TCR7 IPS Colorful LCD Screen Smart Thermostat Owner’s Manual

BEOK CONTROLS TDR89 Thermostat User Guide

BEOK CONTROLS TCR8 IPS Colorful LCD Screen Smart Thermostat Owner’s Manual

BEOK CONTROLS TGW60 Touch Screen Boiler Thermostat User Guide

BEOK CONTROLS TGR86 WiFi Thermostat User Guide

BEOK CONTROLS BOT-323W Series Boiler Thermostat Instruction Manual

BEOK CONTROLS TDS72 Digital Screen Thermostat Instruction Manual

BEOK CONTROLS BOT-R6W Gas Boiler Thermostat Instruction Manual

Beok Controls TS4 Series Thermostat User Guide

BEOK BOT-R7X Manual: Questions and Answers
Why won't my BEOK BOT-R7X turn on or respond to heating commands?
Check if batteries are installed correctly and that the boot key works. Inspect the rear shell installation for deformation.
- Verify batteries are not installed backwards.
- Test whether the boot key is functional.
- Loosen and reinstall the rear shell if it appears deformed. Instructions, p. 3
Can I use the BEOK BOT-R7X with symbols in my Wi-Fi password?
No. Only numbers and letters are supported for the Wi-Fi name and password. Symbols cannot be used. Instructions, p. 3