Code Matching Process:
Programming Mode Operation
In the POWER ON state, press and hold the
button for 5 seconds
to enter programming mode. After entering programming mode, press
button to switch parameters, rotate the outer frame to adjust
various parameters, press the
press the button to adjust the temperature. The adjustment
method for the following time periods is the same as the first time
period. Press the button to save and exit.
button to adjust for minutes, and
Code matching
key
Key
Option
Icon
Time
Adjust Default Adjust
time
Value
20°C
16°C
16°C
16°C
22°C
16°C
22°C
16°C
Temp.
• Output indicator
Workday
1
2
3
4
5
6
1
2
06:00
08:00
11:30
12:30
17:00
22:00
08:00
23:00
• Code matching indicator
• Power indicator
Rotate
Outer
Rotate
Outer
1. Power on the receiving panel, the power indicator is long on.
Press and hold the code matching button for 3 seconds, and the code
matching indicator flashes.
Frame
Frame
Day Off
Parameter Setting
In the POWER OFF state, long press the
enter the parameter setting interface. At this time, press the
to cycle through the selection of the parameters to be set, rotate the
button for 5 seconds to
button
outer frame to adjust the parameters of each item, and press the
button to save and exit.
Paramet Parameter
Default
Value
Functional Meaning
er Item
Name
2. Install three pieces AA batteries on the transmitting panel.
The temperature
compensation
-9.9~9.9°C
In the POWER OFF state, press and hold the
button
Temperature
compensation
1
0
1
range:
for 5 seconds to check the code. When the code checking indicator
light on the receiving panel remains on, the code checking is
successful.
Switch
deviation
setting
The temperature difference
start-up range is 0.5~10°C
2
3
OFF: Turn off the antifreeze
function
ON: Turn on antifreeze
function
The shutdown
antifreeze
function starts
and stops
ON
2
0: Turn off programming
1: Take a day off
2: Two-day weekend
3: No rest
Rest
day
4
selection
Set the upper
limit of the 60°C
temperature
Set the upper temperature
range from 15~95°C
5
6
Long press
display “——_” to
restore factory settings
for 3 seconds,
Restore
—
factory settings
| General | Details |
|---|---|
| Name | BEOK CONTROLS BOT-R7X Wireless Gas Boiler Heating Thermostat Instructions |
| Make | BEOK CONTROLS |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.22 MB |

BEOK CONTROLS TDR83 WiFi Heating Thermostat User Guide

BEOK CONTROLS TCR7 IPS Colorful LCD Screen Smart Thermostat Owner’s Manual

BEOK CONTROLS TCR8 IPS Colorful LCD Screen Smart Thermostat Owner’s Manual

BEOK CONTROLS TDR89 Thermostat User Guide

BEOK CONTROLS TGW60 Touch Screen Boiler Thermostat User Guide

BEOK CONTROLS TGR86 WiFi Thermostat User Guide

BEOK CONTROLS BOT-323W Series Boiler Thermostat Instruction Manual

BEOK CONTROLS TDS72 Digital Screen Thermostat Instruction Manual

BEOK CONTROLS BOT-R6W Gas Boiler Thermostat Instruction Manual

Beok Controls TS4 Series Thermostat User Guide