Home > BEOK CONTROLS > BEOK CONTROLS BOT-R7X Wireless Gas Boiler Heating Thermostat Instructions

BEOK CONTROLS BOT-R7X Wireless Gas Boiler Heating Thermostat Instructions

Code Matching Process:  
Programming Mode Operation  
In the POWER ON state, press and hold the  
button for 5 seconds  
to enter programming mode. After entering programming mode, press  
button to switch parameters, rotate the outer frame to adjust  
various parameters, press the  
press the button to adjust the temperature. The adjustment  
method for the following time periods is the same as the first time  
period. Press the button to save and exit.  
button to adjust for minutes, and  
Code matching  
key  
Key  
Option  
Icon  
Time  
Adjust Default Adjust  
time  
Value  
20°C  
16°C  
16°C  
16°C  
22°C  
16°C  
22°C  
16°C  
Temp.  
Output indicator  
Workday  
1
2
3
4
5
6
1
2
06:00  
08:00  
11:30  
12:30  
17:00  
22:00  
08:00  
23:00  
Code matching indicator  
Power indicator  
Rotate  
Outer  
Rotate  
Outer  
1. Power on the receiving panel, the power indicator is long on.  
Press and hold the code matching button for 3 seconds, and the code  
matching indicator flashes.  
Frame  
Frame  
Day Off  
Parameter Setting  
In the POWER OFF state, long press the  
enter the parameter setting interface. At this time, press the  
to cycle through the selection of the parameters to be set, rotate the  
button for 5 seconds to  
button  
outer frame to adjust the parameters of each item, and press the  
button to save and exit.  
Paramet Parameter  
Default  
Value  
Functional Meaning  
er Item  
Name  
2. Install three pieces AA batteries on the transmitting panel.  
The temperature  
compensation  
-9.9~9.9°C  
In the POWER OFF state, press and hold the  
button  
Temperature  
compensation  
1
0
1
range:  
for 5 seconds to check the code. When the code checking indicator  
light on the receiving panel remains on, the code checking is  
successful.  
Switch  
deviation  
setting  
The temperature difference  
start-up range is 0.5~10°C  
2
3
OFF: Turn off the antifreeze  
function  
ON: Turn on antifreeze  
function  
The shutdown  
antifreeze  
function starts  
and stops  
ON  
2
0: Turn off programming  
1: Take a day off  
2: Two-day weekend  
3: No rest  
Rest  
day  
4
selection  
Set the upper  
limit of the 60°C  
temperature  
Set the upper temperature  
range from 15~95°C  
5
6
Long press  
display “——_” to  
restore factory settings  
for 3 seconds,  
Restore  
factory settings  
GeneralDetails
NameBEOK CONTROLS BOT-R7X Wireless Gas Boiler Heating Thermostat Instructions
MakeBEOK CONTROLS
LanguageEnglish
FiletypePDF (Download)
File size0.22 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
BEOK CONTROLS TDR83 WiFi Heating Thermostat User Guide
BEOK CONTROLS TDR83 WiFi Heating Thermostat User Guide
BEOK CONTROLS TCR7 IPS Colorful LCD Screen Smart Thermostat Owner’s Manual
BEOK CONTROLS TCR7 IPS Colorful LCD Screen Smart Thermostat Owner’s Manual
BEOK CONTROLS TCR8 IPS Colorful LCD Screen Smart Thermostat Owner’s Manual
BEOK CONTROLS TCR8 IPS Colorful LCD Screen Smart Thermostat Owner’s Manual
BEOK CONTROLS TDR89 Thermostat User Guide
BEOK CONTROLS TDR89 Thermostat User Guide
BEOK CONTROLS TGW60 Touch Screen Boiler Thermostat User Guide
BEOK CONTROLS TGW60 Touch Screen Boiler Thermostat User Guide
BEOK CONTROLS TGR86 WiFi Thermostat User Guide
BEOK CONTROLS TGR86 WiFi Thermostat User Guide
BEOK CONTROLS BOT-323W Series Boiler Thermostat Instruction Manual
BEOK CONTROLS BOT-323W Series Boiler Thermostat Instruction Manual
BEOK CONTROLS TDS72 Digital Screen Thermostat Instruction Manual
BEOK CONTROLS TDS72 Digital Screen Thermostat Instruction Manual
BEOK CONTROLS BOT-R6W Gas Boiler Thermostat Instruction Manual
BEOK CONTROLS BOT-R6W Gas Boiler Thermostat Instruction Manual
Beok Controls TS4 Series Thermostat User Guide
Beok Controls TS4 Series Thermostat User Guide

BEOK CONTROLS BOT-R7X Wireless Gas Boiler Heating Thermostat Instructions