Home > BEOK CONTROLS > BEOK CONTROLS TCR8 IPS Colorful LCD Screen Smart Thermostat Owner’s Manual
BEOK CONTROLS TCR8 IPS Colorful LCD Screen Smart Thermostat Owner’s Manual
IPS Colorful LCD Screen Smart Thermostat
03.11 Thur
18:00
68%
Programmable device, multiple periods allowed to set per day.
18.5℃
ROOM
Fair 22℃
The device can be controlled by voice through Amazon Alexa
and Google Assistant
25.5℃
Humidity
68%
Parameter
next
enter
Supply voltage
AC100~240V;50/60Hz
Wi-Fi 3W Max
Power consumption
Temp. setting range
Floor limited range
On/off deviation
home
back
5~95℃(41~203℉)
20~90℃(68~194℉)
0.5~10℃(1~10℉),Factory setting 1℃
-5~50℃(68~122℉)
IP20
Ambient temperature
Protection level
Shell material
Anti-Flammable PC
Version:TCR8 1.1(12/2022)
Product Overview
Wi-Fi setting
This series of thermostat has Floor Heating, Fan Coil, and Integrated version, meeting the
requirements under different scenarios.
Bluetooth Mode
Bluetooth Mode
Access Point Mode
Access Point Mode
Version
System mode
Model
EP
Application
Wi-Fi setting
Built-in & floor sensor, floor limit sensor +
Weekly programming
Bluetooth Mode(Suggest)
Access Point Mode
Floor heating
Floor heating
WP ANC/NO dual-output + Weekly programming
ANC/NO dual-output + Weekly programming+
WPB
Potential-free output
Timer task + 2-pipe system
Please don't leave,
Bluetooth is in the network...
Please don't leave,
Access Point is in the network...
AC2
Timer task + 2-pipe system +Timer task + Potential-free
output + 485Modbus (optional) + Room card (optional)
AC2-485
Heating /Cooling /
Ventilation
Fan Coil
Timer Task Setting (Fan Coil/Integrated)
Timer task + 4-pipe system +Timer task + Potential-free
output + 485Modbus (optional) + Room card (optional)
Press“
”to enter the menu page. Turn the knob“
”, choose “Auto Mode”, and
AC4
then choose “ Schedule ”. Set the parameters by turning the knob, then press
“ Home ”to save and exit to home page.
Fan-Coil with
Floor-Heating
air condition system
Floor heating & fan coil, weekly programming +
Potential-free output + Timer task +
485Modbus (optional) + Room card (optional)
Integrated
AWY
Schedule
00:00
Time Setting
Repeat
00:00
ON
OFF Everyday
Everyday
OFF
Display Symbols
Add
Action
Child-lock Mode
Frost Protection
Wi-Fi
Time Display
03.11 Thur
18:00
Date Week
Room humidity
Set Temp.
Advanced Setting (Usually for Professional Technicians)
68%
18.5℃
RROOOOMM
Outdoor temp.
Fair 22℃
Under power-on status, long press menu button “
” to enter the menu page, choose
Outdoor humidity
Engineer Mode, enter the advanced setting page.After setting the parameters, press
25.5℃
Humidity
68%
Working mode
Fan
menu button “
” to save and exit.
Fan Coil valve
Floor Heating valve
Integrated
FloorHeating
Fan Coil
Auto Mode
Manual Mode
Temporary Mode
next
enter
Default
Value
function list
”
heel “
Handw
Mode
Menu
AWY
AC2-
485
AC4 AC2 EP WP WPB
Adjustment range 0~250
home
back
ModBus Address
0
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
√
× √
√ √
√ √
√ √
√ √
√ √
√ √
√
√
√
√
√
√
√
√
√
√
√
√
√
√
Knob
Sensor Calibration -9.9~9.9℃(-9.9~9.9℉)
0℃
1℃
50℃
5℃
OFF
℃
Fan Speed
Temp. Dif.
0.5~10℃(1~10℉)
5~95℃(41~203℉)
5~47℃(41~117℉)
Max Setting Value
Min Setting Value
Temperature Control Mode(Floor Heating/Integrated)
Auto Mode
Anti-FreezeProtection ON/OFF
Temperature Unit
℃/℉
Built-insensor
Floorsensor
Built-inControl&FloorLimitation
Sensor Mode
IN
√
√
√
×
×
×
×
×
×
× √
× √
× √
√
√
√
√
√
√
Manual Mode
Thermostat works based on manually-set temperature, disconnecting from
auto mode.
Floor limited Value
20~90℃(68~194℉)
35℃
2-day
Monday to Friday
Monday to Satuiday
Monday to Sunday
Temporary Mode
Thermostat works based on manually-set temperature temporarily and then
shifts back to auto mode till next event.
00: Fan speed controllable
01: Fan speed uncontrollable
Fan control settings
LinkageTime Delay
00
√
√
√
×
√
×
√ ×
× √
×
√
×
√
0~5min
0min
User Operation
None
Lock All
All but power
None
Last
√
√
√
√
√
√
√ √
√ √
√
√
√
√
Temp setting:
System mode:
Rotate handwheel“
”to change setting temperature by 0.5°C.
Function Off
Function On
Function Saved
Press “ ” shortly to switch cooling/heating/ventilation. (Fan Coil)
Press “ ” shortly to switch cooling/heating/ventilation/floor heating/floor
heating + heating. (Integrated)
All/Cold Only
Air-Condition Mode
Temp Control
All
Manual
/
√
√
√
√
×
√
√
×
√
√ ×
× ×
√ √
×
×
√
×
×
√
Manual/Auto
Yes/No
Temp control mode:
Reset All Settings
Press “
Press “
” enter the menu interface.
” + “ ” for 3 seconds to activate child-lock.
Enter menu:
Child-lock:
| General | Details |
|---|---|
| Name | BEOK CONTROLS TCR8 IPS Colorful LCD Screen Smart Thermostat Owner’s Manual |
| Make | BEOK CONTROLS |
| Language | English |
| Filetype | PDF (Download) |
| File size | 1.8 MB |

BEOK CONTROLS TDR83 WiFi Heating Thermostat User Guide

BEOK CONTROLS TCR7 IPS Colorful LCD Screen Smart Thermostat Owner’s Manual

BEOK CONTROLS TDR89 Thermostat User Guide

BEOK CONTROLS BOT-R7X Wireless Gas Boiler Heating Thermostat Instructions

BEOK CONTROLS TGW60 Touch Screen Boiler Thermostat User Guide

BEOK CONTROLS TGR86 WiFi Thermostat User Guide

BEOK CONTROLS BOT-323W Series Boiler Thermostat Instruction Manual

BEOK CONTROLS TDS72 Digital Screen Thermostat Instruction Manual

BEOK CONTROLS BOT-R6W Gas Boiler Thermostat Instruction Manual

Beok Controls TS4 Series Thermostat User Guide

BEOK CONTROLS TCR8 IPS Colorful LCD Screen Smart Thermostat Owner’s Manual Overview
Summary of Contents
- Page 1: IPS Colorful LCD Screen Smart Thermostat Programmable device, multiple periods allowed to set per day. The device can be controlled by voice through Amazon Alexa and Google Assistant. This series of thermostat has Floor Heating, Fan Coil, and Integrated version, meeting the requirements under different scenarios. Built-in & floor sensor, floor limit sensor + Weekly programming. Timer task + Potential-free output + 485Modbus (optional) + Room card (optional). Advanced Setting (Usually for Professional Technicians). Thermostat works based on manually-set temperature, disconnecting from auto mode. Temporary Mode: Thermostat works based on manually-set temperature temporarily and then shifts back to auto mode till next event. Press “ ” shortly to switch cooling/heating/ventilation.
- Page 2: IPS Colorful LCD Screen Smart Thermostat Installation instructions Connecting Diagram The thermostat operates in full capacity in areas with the altitude of less than 2500 above sea level. Power rating of external load should be less than or equal to 80% rated power of the thermostat in areas with altitude of 2500m to 4200m. The thermostat adopts pre-guide and limited snap-fit design. It is easy to mount. Suggested wire-stripping length is 7-9mm. Make sure that the thermostat is fixed without deformation. Suggested torque is 0.2~0.4N.m (2.0~4.1kgf.cm). Linkage control; delay time of linkage control is adjustable. Dry contact signal to control boiler. Room card linkage (optional).