Home > BEOK CONTROLS > BEOK CONTROLS TR9B Capacitive Touch LCD Smart Thermostat Owner’s Manual
BEOK CONTROLS TR9B Capacitive Touch LCD Smart Thermostat Owner’s Manual
Ultra-large colorful screen capacitive touch LCD smart thermostat
√The device can obtain local weather condition and outdoor
temperature (optional)
√Customized exclusive temperature plan - up to 6 events allowed
to set per day
Sail-shape curved design - fashion, elegant and enduring
UItra-large screen -better user interaction experience
√
√
√
485 modbus and room card linkage - customized equipment (optional)
Parameter
Supply voltage
AC100~240V; 50/60Hz
1W Max (Wi-Fi 3W Max)
5~95℃(41~99℉)
20~90℃(68~99℉)
0.5~10℃(1~10℉), Factory setting ±1℃
-5~50℃(23~99℉)
IP20
Power consumption
Temp. setting range
Floor limited range
Temp. Dif.
Ambient temperature
Protection level
Shell material
Anti-Flammable PC
Version:TR9B 1.6(12/2023)
Product Overview
This series of thermostat has Floor Heating, Fan Coil, and Integrated version, meeting the
requirements under different scenarios.
User Operation
Power on/off : Press “ ” shortly to turn on/off the thermostat.
Auto-mode :
Press “ ” for 3 seconds to edit auto-mode settings.(Floor Heating/Integrated)
Press “ ” for 3 seconds to edit timer task. (Fan Coil/Integrated)
Timer task:
Version
System mode
Model
EP
Application
Time setting:
Press “ ” for 3 seconds to set time.(Floor Heating)
Built-in & floor sensor, floor limit sensor +
Weekly programming
Press “ ” twice for 3 seconds to set time.(Automatic time synch for Wi-Fi version)
Press “ ” or “ ” shortly to change setting temperature by 0.5°C.
Floor
heating
Heating
Temp setting:
Child-lock:
ANC/NO dual-output + Weekly programming
WP
ANC/NO dual-output + Weekly programming+
Potential-free output
Press “ ” + “ ” for 3 seconds to activate child-lock.
Press “ ” shortly to switch cooling/heating/ventilation.(Fan Coil)
Press “ ” shortly to switch cooling/heating/ventilation/floor heating/floor
heating + heating.(Integrated)
WPB
System mode:
Timer task + 2-pipe system
AC2
Heating /Cooling /
Ventilation
Fan Coil
AC2-485 Timer task + 2-pipe system + 485Modbus (optional)
Press “ ” shortly to switch manual/auto mode.(Floor heating)
Press “ ” shortly to switch manual/auto mode.(Integrated, floor heating)
Press “ ” shortly to adjust fan speed.(Fan Cail/Integrated)
Press“ ”shortly to set to ECO mode 18°C(64°F). (Floor heating)
Temp control mode:
Timer task + 4-pipe system + 485Modbus (optional)
AC4
Heating / Cooling /
Integrated Ventilation/Floor heating /
Floor heating + Heating
Floor heating & fan coil, weekly programming +
Potential-free output + Timer task +
485Modbus (optional) + Door card (optional)
Fan speed setting:
ECO mode:
AWY
Advanced Setting (Usually for Professional Technicians)
Under power-off, press “ ” for 3 seconds to enter advanced setting mode, then re-press
Display Symbols
“
” to switch to next mode. Press “ ” to save and exit advanced setting mode.
Floor
Heating
Integrated
FanCoil
Child-lock
Frost Protection
Wi-Fi(optional)
Timer Task
Default
Value
Meaning
Code
“
”or“
”
Time Display
AC2-
AWY
AC4 AC2 EP WP WPB
485
Indoor humidity(optional)
Postal address(optional) Adjustment range 0x00~0xFA
00
01
02
√
√
√
√ √
√ √ √
00
×
Wake up; Event 1
Leave (am); Event 2
Return (am); Event 3
Leave (pm); Event 4
Return (pm); Event 5
Sleep; Event 6
Weather forecast
(optional)
%
RH
Temp. calibration
Temp. Dif.
-9.9~9.9℃(-9~9℉)
√ √ √ √ √ √
-3℃
±1℃
Fan-Coil Cooling Mode
Fan-Coil Ventilation Mode
Room Temp.
Fan-Coil Heating Mode
Floor Heating Mode
Room Temp.
0.5~10℃(1~10℉)
√
√
√
√ √ √
√ √ √
√ √ √
√ √
√ √
√ √
Temp. upper limit
Temp. lower limit
03
04
5~95℃(41~99℉)
√
√
50℃
5℃
Set to
5~47℃(41~99℉)
Setting temp.
ON: frost protection on
OFF: frost protection off
Frost protection
Temperature unit
05
06
OFF √
√
√
√ √ √
√ √ √
√ √
√ √
Floor Temp.
Floor Heating on
Fan-Coil Heating on
Cooling on
Auto
ECO Mode
Manual Mode
Auto Mode
℃/℉
℃
√
IN:Controlledbybuilt-insensor
OUT:Limitedbyfloorsensor
ALL:Controlledbybuilt-insensorand
limitedbyfloorsensor
Temporary Mode
Fan
Week Display
Sensor selection
07
IN
√
×
√ √ √
√ √ √
× ×
× ×
Power
on/off
ECO/FanSpeed
Mode
Up
Down
Floor limited Value
08
09
20~90℃(68~99℉)
√
×
×
35℃
12345: 5/2 week mode
123456: 6/1 week mode
1234567: 7/0 week mode
Weeklyprogramming
setting
12345 √
× × √ √ √
Week Display
Wi-Fi
Frost Protection
00: Fan speed controllable
01: Fan speed uncontrollable
Timer Task
Fan control settings
Delaytimeofoutputs
10
11
00
√
√
√ √ √ × × ×
× × × √ √ √
Child-lock
Time Display
Room Temp.
Floor Heating Mode
0~5min
0
Fan-Coil Heating Mode
00: Child-lock inactivate when screen off;
lock all when child-lock activate
01: Child-lock activate when screen off;
lock all when child-lock activate
02: Child-lock activate when screen off;
lock all except Fan Speed, Up and
Down when child-lock activate
03: Child-lock activate when screen off;
lock all except Power on/off when
child-lock activate
ECO Mode
Fan-Coil Cooling Mode
Fan Speed Display
Cooling on
Room Temp.
Floor Temp.
Heating on
Fan-Coil Ventilation Mode
Manual Mode
Wake up; Event 1
Leave (am); Event 2
Return (am); Event 3
Leave (pm); Event 4
Return (pm); Event 5
Sleep; Event 6
Child-lock
12
00
√
√
√ √ √
√ √
Auto Mode
Temporary Mode
Power
on/off
00: Power OFF
Mode
ECO/FanSpeed
Up
Down
01: Power ON
Boot Status
13
14
02
00
√
√
√ √ √ √ √ √
√ × × × × ×
02:The last status before power loss
00:turnoffroomcardfunction
01:settoECOtemp. afterpullingroom
cardout
02:staypower-offafterpullingroom
cardout
Temperature Control Mode(Floor Heating/Integrated)
Manual Mode
Thermostat works based on manually-set temperature, disconnecting from auto mode.
Room card status
Room card heating
ECO temp.
Room card cooling
ECO temp.
Auto Mode
Weekly-circled programme, up to 6 heating events can be set per day. Heating events,
workdays and temperature can be separately customized based on personal routines.
15
16
17
10~21℃(50-69℉)
√
√
√
√ × × × × ×
√ × × × × ×
√ √ √ × × ×
18℃
26℃
00
22~32℃(72-89℉)
00: Cooling and heating
01: Cooling only
Fancoilmodesetting
Temporary Mode
Thermostat works based on manually-set temperature temporarily and then shifts
back to auto mode till next event.
Weeklyprogramming 00: turn on
forIntegrated
Reset
18
19
01
/
√
√
×
√
× × ×
√ √ √
× ×
√ √
01: turn off
Press “ ”for 3 seconds to reset
| General | Details |
|---|---|
| Name | BEOK CONTROLS TR9B Capacitive Touch LCD Smart Thermostat Owner’s Manual |
| Make | BEOK CONTROLS |
| Language | English |
| Filetype | PDF (Download) |
| File size | 1.56 MB |

BEOK CONTROLS TDR83 WiFi Heating Thermostat User Guide

BEOK CONTROLS TCR7 IPS Colorful LCD Screen Smart Thermostat Owner’s Manual

BEOK CONTROLS TDR89 Thermostat User Guide

BEOK CONTROLS BOT-R7X Wireless Gas Boiler Heating Thermostat Instructions

BEOK CONTROLS TCR8 IPS Colorful LCD Screen Smart Thermostat Owner’s Manual

BEOK CONTROLS TGW60 Touch Screen Boiler Thermostat User Guide

BEOK CONTROLS TGR86 WiFi Thermostat User Guide

BEOK CONTROLS BOT-323W Series Boiler Thermostat Instruction Manual

BEOK CONTROLS TDS72 Digital Screen Thermostat Instruction Manual

BEOK CONTROLS BOT-R6W Gas Boiler Thermostat Instruction Manual

BEOK CONTROLS TR9B Capacitive Touch LCD Smart Thermostat Owner’s Manual Overview
Summary of Contents
- Page 1: Ultra-large colorful screen capacitive touch LCD smart thermostat The device can obtain local weather condition and outdoor temperature (optional). Customized exclusive temperature plan - up to 6 events allowed to set per day. Sail-shape curved design - fashion, elegant and enduring. User operation includes power on/off, auto-mode settings, and timer task. This series of thermostat has Floor Heating, Fan Coil, and Integrated version, meeting the requirements under different scenarios. Weekly programming allows for setting time and temperature based on personal routines. Child-lock feature can be activated for safety. ECO mode is available for energy-saving settings. Advanced setting mode is accessible for professional technicians.
- Page 2: Ultra-large colorful screen capacitive touch LCD smart thermostat Auto-mode setting (Floor Heating / Integrated) The thermostat operates in full capacity in areas with the altitude of less than 2500 above sea level. Power rating of external load should be less than or equal to 80% rated power of the thermostat in areas with altitude of 2500m to 4200m. Press “ ” for 3 seconds to edit auto-mode setting. Press “ ” for 3 seconds to enter timer task setting; press “ ” to change settings. The thermostat adopts pre-guide and limited snap-fit design. It is easy to mount. Release front cover by inserting a head screwdriver into bottom crack. Insert the wires and then fix these wires with screws. Suggested wire-stripping length is 7-9mm. Make sure that the thermostat is fixed without deformation. Suggested torque is 0.2~0.4N.m (2.0~4.1kgf.cm).