Home > FantiniCosmi > FantiniCosmi CH143E 230V Flush Mounting Weekly Programmable Thermostat User Manual

FantiniCosmi CH143E 230V Flush Mounting Weekly Programmable Thermostat User Manual

FLUSH MOUNTING WEEKLY PROGRAMMABLE THERMOSTAT,  
230V  
ENG  
INSTALLATION AND USER MANUAL  
GeneralDetails
NameFantiniCosmi CH143E 230V Flush Mounting Weekly Programmable Thermostat User Manual
MakeFantiniCosmi
LanguageEnglish
FiletypePDF (Download)
File size0.89 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
FantiniCosmi C820RQ LED Thermostat Instruction Manual
FantiniCosmi C820RQ LED Thermostat Instruction Manual
FantiniCosmi CH123E 230V Flush Mounting Thermostat Installation Guide
FantiniCosmi CH123E 230V Flush Mounting Thermostat Installation Guide
FantiniCosmi CH193WiFi Weekly Programmable Thermostat Instruction Manual
FantiniCosmi CH193WiFi Weekly Programmable Thermostat Instruction Manual
FantiniCosmi C16 Room Thermostat Owner’s Manual
FantiniCosmi C16 Room Thermostat Owner’s Manual

FantiniCosmi CH143E 230V Flush Mounting Weekly Programmable Thermostat User Manual
Get the free PDF manual for the FantiniCosmi CH143E 230V Flush Mounting Weekly Programmable Thermostat User Manual and access setup steps, usage instructions, and troubleshooting tips. 👉 View online or download now to keep your thermostat running smoothly!

FantiniCosmi CH143E 230V Flush Mounting Weekly Programmable Thermostat User Manual Overview

Summary of Contents

  • Page 1: Flush mounting weekly programmable thermostat installation and user manual.
  • Page 2: Intellicomfort CH143E Flush mounting weekly programmable thermostat, 230V Thank you for purchasing the Fantini Cosmi flush mounting weekly programmable thermostat, model CH143E, for temperature management and home comfort. This manual contains all the information required for correct installation and configuration. Carefully read the installation instructions, safety warnings, operating modes, and maintenance instructions in this booklet, which should be kept for further reference. After removing the packaging, check the integrity of the appliance; if in doubt, do not use it. Installation of the appliance should only be carried out by qualified technicians in compliance with current standards. The use of any electrical appliance involves observing certain basic rules. Do not touch the device with wet hands or wet feet or bare feet. Do not expose the device to the weather (rain, sun, etc.). Before carrying out any maintenance or cleaning work, switch off the power supply. Do not power the appliance with the cover open.
  • Page 3: Intellicomfort CH143E Technical features Installation Electrical connections Buffer battery function Quick guide for programming Description of keys Setting time and date Operating programs Settable temperatures Functions in detail Maintenance Disposal Contents of package 1 programmable thermostat 1 frames 1 white covers, type A 2 screws 1 user manual
  • Page 4: Intellicomfort CH143E Technical features Temperature adjustment scale Power supply: 230V 50Hz Maximum power consumption: 5.5 VA Connection to boiler: 3 screw clamps (closed + open) Type of action: 1BU micro disconnection Software class: A Electric insulation: double insulation Degree of protection: IP20 Dimensions: 68 x 52.5 x 58 mm
  • Page 5: Intellicomfort CH143E The CH143E programmable thermostat must be installed in a 3-module recessed box, in the middle of the apartment, preferably 1.5 m off the ground. The required components are all included in the package according to the following table.
  • Page 6: Installation and maintenance operations must be carried out with the system's electrical power switched off and by qualified personnel, in compliance with the regulations in force. Act on the master switch on the electric panel to cut power to the electrical system. Detach the tabs according to the type of plate when required. Fasten the programmable thermostat to the suitable frame. Mount the cover on the body of the programmable thermostat. Connect the two wires of the boiler to terminals 1-2 of CH143E. Screw the frame onto the box using the provided screws. Mount the plate. Switch the electric system back on.
  • Page 7: Intellicomfort CH143E Electrical connections Installation and maintenance operations must be carried out with the system's electrical power switched off and by qualified personnel, in compliance with the regulations in force. When CH143E is disconnected, the boiler contact remains in its current position. Buffer battery function During black-outs, the programmed parameters will not be lost as the settings are stored in a non-volatile memory. The internal battery of CH143E allows it to maintain the date/time during blackouts. The chronothermostat works properly even when the battery is discharged, but during blackouts it is not assured that the date/time will be maintained.
  • Page 8: Intellicomfort CH143E Quick guide for programming Description of keys The programmable thermostat is equipped with 6 keys, the function of which varies depending on the situation. Pressing a key once has no effect aside from switching on the light on the display. Setting time and date After the device switches on, press the key PROG briefly: the text “Setup” is displayed. Set the hour by pressing the appropriate keys. Pressing again allows you to choose whether to disable automatic change of summer/winter time. This function is initially active but can be deactivated. To exit the Setup menu, press ENTER and the appropriate key.
  • Page 9: Intellicomfort CH143E Operating programs The CH143E programmable thermostat has different operating modes, called programs. Auto weekly program: One of the four programmable temperatures can be associated to each half hour for each day of the week. Holiday daily program: You may select one of the programmable temperatures for each half hour, but the identical sequence will be repeated every day. Jolly temporary program: You may choose to hold a certain temperature for a certain number of hours, after which it will go back to the previously active program. Man manual program: The programmable thermostat maintains a fixed temperature, specified each time, for an unlimited amount of time until another program is selected.
  • Page 10: Intellicomfort CH143E System off or with antifreeze program “off/antifreeze”: The system remains off or maintains a very low temperature (from 2 to 7°C) to prevent the fluid in the heating system from freezing. Settable temperatures: Four different temperatures can be set for each half hour of the day in the AUTO and HOLIDAY programs. Three temperatures (T1, T2, T3) can range from 2° to 40°C, while the antifreeze temperature (TA) can range from 2° to 7°C or be set to “OFF”. Setting operating programs: Press SEL to select the different operating programs in cyclical sequence: AUTO -> MAN -> OFF -> HOLIDAY -> AUTO. JOLLY temporary program: The JOLLY program is not included in the program sequence but can be selected directly by pressing the JOLLY key. Setting the temperatures: Press TEMP in the AUTO, HOLIDAY, and OFF programs to change the value of the four programmable temperatures. Use the arrow keys to adjust the temperature by a tenth of a degree at a time. Temperature constraints: T1 will always be less than or equal to T2, and T2 will always be less than or equal to T3.
  • Page 11: Intellicomfort CH143E In the JOLLY program, pressing TEMP alternates the view of the set temperature and the hours remaining until the end of the program. The MAN program allows you to modify the fixed temperature using the keys. Editing current date and time can be done by briefly pressing the key to enter the “Setup” menu. This menu allows you to program the weekly profiles (AUTO program) and daily profiles (HOLIDAY program) and to set the advanced functions. If the text “Setup” appears instead of “Config”, you must press the key long enough to access the configuration. When you enter the “Config” menu, you can choose the desired temperature for each half hour of the indicated day. Pressing allows you to move one half hour at a time to the right or to the left. Pressing briefly switches you to the next day in the programming sequence. Press COPY to copy the temperature profile of the current day to the following day. Pressing ENTER from the Correction page allows you to exit the “Config” menu.
  • Page 12: Intellicomfort CH143E “JOLLY” program setting allows you to define the desired temperature and its duration in hours, up to a maximum of 240 hours. You can modify the duration, which initially is one hour, and increase or decrease the number of hours using designated keys. Pressing TEMP allows you to view and modify temperature settings. When the JOLLY program duration elapses, the system returns to the initial program. “OFF/ANTIFREEZE” program setting switches the thermostat to off/antifreeze status. The antifreeze temperature can be programmed between 2.0 and 7.0°C using the arrow keys. Pressing OFF again returns you to the previous operating status. Alternative displays in AUTO and HOLIDAY programs can show different information by pressing the DISP key. The first press shows the programmed temperature for the current half hour, the second displays the date, and the third returns to the initial temperature profile.
  • Page 13: Intellicomfort CH143E Functions in detail Available programs CH143E has several operating modes (programs): - “AUTO” weekly program - “HOLIDAY” daily program - “JOLLY” temporary program - “MAN” manual program - system off or with antifreeze “OFF” program “AUTO” weekly program 4 temperature levels can be used in the AUTO operating mode (Ta, T1, T2, T3), programmed with 30 minute steps, 24 hours a day, 7 days a week. The default for days 1 – 5 (Monday to Friday) is: - 00:00 – 06:30 T1 - 06:30 – 09:00 T2 - 09:00 – 11:30 T1 - 11:30 – 14:00 T2 - 14:00 – 17:00 T1 - 17:00 – 22:30 T3 - 22:30 – 24:00 T1 The default for days 6 and 7 (Saturday and Sunday) is: - 00:00 – 08:00 T1 - 08:00 – 11:30 T2 - 11:30 – 23:00 T3 - 23:00 – 24:00 T1
  • Page 14: Intellicomfort CH143E The value of the 4 temperatures can be programmed using the TEMP function. The temperature profile (hourly variation) can be programmed using the PROG function. For summer mode (air conditioning), the default program is that shown in the figure. 4 temperature levels can be used in HOLIDAY operating mode, according to a programming with 30 minute steps. This achieves a daily programming, regardless of the days of the week. The default temperature profile is: T3 20, T2 19, T1 17. The JOLLY mode allows you to set programmable temperature (Tj) for a programmable number of hours (from 1 to 240). It is used when you wish to introduce a temporary variation to programming without changing the parameters. If you enter JOLLY mode using the specific function key, when time is up it goes back automatically to programming in progress.
  • Page 15: Intellicomfort CH143E manual T1 temperature settable from 2 to 40°C MAN mode allows you to set a fixed temperature manually (Tman), ranging from +2.0 to +40.0 degrees. It can be used to keep the house at a different temperature than that of the daily program when no one is home. OFF mode is used when you want to switch the system off. It uses the temperature TA (antifreeze) as a reference to guarantee protection of the system at low temperatures. The system can use 4 different temperature levels, three for normal use and one called “antifreeze”. Programming of the three T is conditioned by reciprocal values. T1 ranges between +2.0 and +T2 degrees. T2 ranges between +T1 and +T3 degrees. TA (antifreeze) ranges between +2.0 and +7.0 degrees, or can be OFF when the boiler remains off.
  • Page 16: Intellicomfort CH143E Advanced keys and functions Using the SEL key allows you to select the operating mode of the programmable thermostat, according to the following programs: Holiday, Auto, Manual, Off. To change the selected program, press SEL in sequence (cyclical). Using the TEMP key in Auto, Holiday, and Off allows you to enter programming of the 4 temperatures used in these statuses. Change the temperatures using the arrow keys, ensuring T1 is no higher than T2, T2 is not lower than T1 and higher than T3, and T3 is not lower than T2. Press TEMP to go to the next temperature (cyclical) T1>T2>T3>TA>T1. In Jolly, pressing TEMP alternates from programming of Tj to that of the duration of Jolly (from zero to 240 hours, equal to 10 days). Use the arrow keys to change Tj (between +2 and +40°) and the duration (1 hour steps).
  • Page 17: Intellicomfort CH143E Using the PROG key Setup for Winter and Summer modes Press to change page and press ENTER to exit PROG Hours setting: Pressing cyclically increases or decreases the hours Minutes setting: Pressing cyclically increases or decreases the minutes Year setting: Pressing increases or decreases the years Month setting: Pressing cyclically increases or decreases the months Date setting: Pressing cyclically increases or decreases the days The programmable thermostat automatically determines the day of the week when the date is set Summer Time setting: Automatically selects summer time and updates the time in March and October
  • Page 18: Intellicomfort CH143E The display of day 1 appears, with the graphical display of the temperatures each half hour. Day 1 corresponds to Monday, and so on. Day H is the Holiday, which does not change during the week. Pressing moves forward a half hour. Press PROG briefly to change the day (1, 2, 3, 4, 5, 6, 7, H). Press COPY to copy the temperature profile of the current day on the following day. This allows you to modify the read temperature, which due to the recessed wall installation might not indicate the true temperature perceived. It is recommended to calibrate it by comparing it with a thermometer placed at the desired height/area. This allows you to choose the temperature display scale between Celsius and Fahrenheit degrees. To adjust back lighting of the display, you can choose not to have it (OFF) or to have it with a duration programmed from 1 to 9 seconds. Allows you to modify the luminous intensity of the display, at 9 levels.
  • Page 19: Intellicomfort CH143E Allows you to change the language used during programming. Press to cyclically switch from one language to another. Allows you to block the keyboard, with the 4-digit password. Pressing switches from NO to YES, and press ENTER to request the password. Press ENTER to store it, going back to the normal operating display. Pressing restores all the parameters to the default values. Displays the software version of the CH143E programmable thermostat. The DISP key allows you to view windows with different information. Currently set temperature is displayed along with the time. The following windows may be viewed: profile of the day, currently set temperature, and date.
  • Page 20: Using the JOLLY key allows you to force a temperature to a fixed value for a preset amount of time. The duration of JOLLY status can be adjusted using the arrow keys. The Jolly temperature is set by pressing the TEMP key. The display shows the Jolly temperature until the key is pressed again. To exit JOLLY mode before time is up, change the number of hours to zero or press SEL to choose a desired status. The OFF key allows you to switch the system off regardless of the current operating status. Pressing OFF again returns you to the previous operating status.
  • Page 21: Resetting the device may be necessary due to unexpected events, such as strong electromagnetic interference. To restart, press the round key (RESET) located inside the device using a paper clip or pin. The device will display “Fantini Cosmi / CH143E” for a few seconds before going to AUTO mode. The previous configuration is retained, and the date and clock are usually not changed. To restore default programming, press RESET in PROG/CONFIG, which will replace all user settings with default settings, except for date and time. For maintenance, use only a soft and dry cloth to clean the device. Do not use water or other liquid substances for cleaning. The crossed-out wheeled bin symbol indicates that the product must be disposed of separately from household waste. Batteries and integrated accumulators may be disposed of together with the product. Participating in separate collection contributes to proper disposal and avoids negative consequences for the environment and human health.
  • Page 22: Page 22
  • Page 23: Page 23