Heating Schedule
Trouble shooting:
Assign seven days a week to the following two schedules:
5+1+1: The Event parameter is the same from Monday to Friday, with separate Event parameters
on Saturday and Sunday.
Problem
Solution
7: With separate Event parameters every day.
1.Check the you have 120V/208V or 240V supplied to the Junction box.
2.Ensure power supply is connected to the Line side of the thermostat (L/N).
3.Contact your installer for troubleshooting support.
Note:Set schedules, the week can be multiple selection, complete batch change.
No display
1. Check the scheduled times are set correctly AM/PM.
2. Confirm thermostat is set to the correct date/Time.
3. Contact your installer for troubleshooting support.
Heating occurs
at wrong times
Select days to program
Period set
Wake
√
√
√
√
FRI
MON
TUE
1
7:00
8:30
22.0°
19.0°
√
SAT
2
Time
6:00
Temp
21.0°
1. Check the floor sensor is connected to IN/SNP terminals.
2. Check the floor sensor has a good ohms reading.
3. Contact your installer for troubleshooting support.
Floor sensor
error
WED
SUN
3
4
17:00
22:00
22.0°
19.0°
THU
Air sensor error
1.Contact your installer for troubleshooting support
√
√
Temperature
limiting
protection
1.Raise the floor protection temperature.
2.Choose to work with a single sensor.
3.Do not do any treatment, wait for the floor temperature to drop.
......
......
Energy Use
This option is used to calculate data on energy usage.The user sets the power in the Power Set.
The thermostat will automatically count the heating time and calculate the energy consumption.
Energy Use
0000KWh
User Settings
Time: Set Time.
User Settings
Date: Set date.
Time
Date
Child lock: Lock all keys to prevent the setting from being changed.
Child Lock
Unit
ock: (Hold on the up button for 3s to unlock)
Unit: °F/°C.
Power Set
Display Brightness
Power Set: 0W-4500W.
Display Brightness: 1-9.
Language: English/Francais
Daylight Saving Time:
Language
When enabled,the thermostat will adjust automatically in daylight
Daylight Saving Time
Set Backlight Delay
saving time.
Support
Set Backlight Delay:
5-60
User Reset
Support:Scan the QR code to view the electronic manual.
For further support, please contact your installer.
User Reset: This will reset the users settings to factory default.
Installer Settings
Adaptive Function: When this feature is enabled, the room will have
reached the target/set temperature when the event begins.If
Open Window: Thermostat can detect an open window and will
shut off heating temporarily to save energy. ;
Installer Settings
Adaptive Function
Open Window
Sensor Application
Sensor Application: 1.Room 2.Floor 3.Room and Floor Protection
Sensor Type
Floor Sensor Calibration
Room Sensor Calibration
Sensor Type: B3950-10K/B3380-10K/B3700-10K/B3600-12K/15K
Floor Sensor Calibration:Measure the temperature by adjusting
the calibration. ±5℃
Room Sensor Calibration:Measure the temperature by adjusting
the calibration. ±5℃
°
Floor Protection:
Floor protection is enabled only when the sensor
type is selected for room and floor simultaneously.If the floor temperature
exceeds the set protection value, the thermostat will display alarm information
and stop working.
Floor Protection
Location
Factory Reset
Reference value:Laminate-max.28°C(82.4°F)/Tile-max.40°C(104°F)
The value ranges from 20°C(68°F)to 50°C(122°F).If
Location: Home/Office.
Factory Reset: This will reset the thermostat to factory settings, Personal
settings will be lost.