Button Functions
RT520TX Wiring Diagram
TPI, SPAN
13
14
15
RT520 / RT520RF Thermostat
RXRT520 Receiver
N
L
RT520, RT520TX, RT520RF
COM
NO
N
L
7
9
8
Using UP or DOWN, enable or
disable DST (Daylight Saving Time).
Press SELECT to confirm.
Press SELECT.
10
OPENTHERM
16
17
18
N
L
1
2
3
4
5
6
1. MENU - enter the menu options, press and
hold for 3 sec to return to main screen or to
deactivate Boost Mode.
2. SELECT - confirm changes and enter menus.
3. DOWN - decrease the temperature and
move through the menus.
7. ON - When in Manual Mode, ON will
turn the boiler on.
8. OFF - When in Manual Mode, OFF
will turn the boiler off.
9. AUTO - Receiver operates in automatic
mode according to the thermostat.
10. MANUAL - Receiver output is
controlled by the On/Off slide switch.
A
B
N
L
4. UP - increase the temperature and move
through menus.
Using UP or DOWN, select your
temperature accuracy.
Press SELECT to confirm.
When OpenTherm is connected, the
device software will automatically
adjust to the OpenTherm settings.
5. BOOST - activate Boost Mode.
6. MANUAL - activate / deactivate Manual Mode.
OpenTherm Power Up and Configuration
Quick Guide
OpenTherm Modulating Control is a method of control used by modern heating systems. Instead of
switching a boiler on and off at intervals, modulating control allows the amount of heat provided by the
boiler to be controlled to match the varying demand from the thermostat. This means the customer has
greater system efficiency, energy saving and room comfort from our heating controls.
LCD Icon Description
1
2
Text Bar
Temperature Unit
OpenTherm - Hot Water
Introduction
3A Day of the week (numeric)
3B Day of the week (alphabetic)
Please make the receiver connections and power the receiver before inserting the batteries
into the thermostat.
1
2
1
2
3
The RT520 and RT520RF are the latest additions to SALUS’ tried and tested RT range of thermostat
heating controls. With a new on-board load compensation feature, they offer the most cost effective
fully compliant Boiler Plus solution on the market providing the homeowner with optimum efficiency
and maximum heating control comfort. Available in both wired and wireless RF versions, the new RT520
series include all the features of the previous RT series with a larger more intuitive LCD display and a
handy new suite of additional operational and efficiency functions.
4
5
6
7
8
9
Clock
AM / PM
Cooling Mode On
Holiday Mode On
Manual Mode On
Heating Mode On
7
9
4
6
8
3A 3B
5
1
2
3
10
12
11
13
Before use please read this manual carefully.
10 Low battery status
11 Wireless connection with the
receiver
Product Compliance
17
Press MENU.
Using UP or DOWN, navigate to
Hot Water submenu and
press SELECT.
Using UP or DOWN, adjust the
temperature and then
press SELECT.
14
12 Service Mode On
13 Temperature measured / set
14 Program number
15 Settings
16 Program indicator
17 Boost function
This product complies with the essential requirements and other relevant provisions of the following EU Directives:
EMC 2014/30/EU, LVD 2014/35/EU, RED 2014/53/EU and RoHS 2011/65/EU. Full text of the EU Declaration of
15
16
4
5
After inserting the batteries, the
thermostat will power up.
Press SELECT.
Using UP or DOWN, choose your
language and then press SELECT.
868.0-868.6MHz; <13dBm
Safety Information
4
5
6
Use in accordance to national and EU regulations. Use the device as intended, keeping it in dry condition.
Product for indoor use only. Installation must be carried out by a qualified person in accordance to national
and EU regulations.
RT520 Thermostat Terminals Description
Always ensure the AC mains power is switched off before installing or working on any
components (this includes replacing the batteries). Use only AA 1.5 V alkaline batteries in the
thermostat. Place the batteries into the battery slot located in the back of the thermostat. Do
not use rechargeable batteries.
Terminal
Description
B / A
NC
OpenTherm Communication Wire
Switched Live OFF
The thermostat will return to the
main screen. Press any button.
The text bar indicates that hot
water is in operation.
NO
Switched Live ON
Using UP or DOWN, choose
the time format.
Press SELECT to confirm.
Using UP or DOWN, set the hour
and then press SELECT.
COM
Common Terminal
Technical Specification
Importer:
SALUS Controls Plc
RT520 Thermostat RT520TX Thermostat
7
8
9
Thermostat supply
2 x AA alkaline batteries 2 x AA alkaline batteries
RXRT520 Receiver Terminals Description
Units 8-10 Northfield Business Park
Forge Way, Parkgate, Rotherham
S60 1SD, United Kingdom
T: +44 (0) 1226 323961
Thermostat rating max
OpenTherm terminals
3 (1) A
A / B
-
-
Terminal
B / A
Description
Voltage free
NC / NO / COM
terminals
OpenTherm Communication Wire
Switch Terminal
Outputs
-
E: sales@salus-tech.com
E: techsupport@salus-tech.com
NO
Temperature range
Temperature accuracy
ErP control class
5°C – 33.5°C
5°C – 33.5°C
0.1°C or 0.5°C
V
COM
Common Switch Terminal
Supply (230 V AC)
0.1°C or 0.5°C
L; N
Using UP or DOWN, set the
minutes and then press SELECT.
Using UP or DOWN, set the year Using UP or DOWN, set the month
and then press SELECT. and then press SELECT.
V
Radio frequency
-
868 MHz
10
11
12
Dimension [mm]
118 x 95 x 26 [mm]
118 x 95 x 26 [mm]
RT520 Wiring Diagram
TPI, SPAN
RXRT520 Receiver
OPENTHERM
SALUS Controls is a member of the Computime Group.
Receiver supply
Receiver rating max
OpenTherm terminals
Outputs
230 V AC
16 (5) A
A / B
Maintaining a policy of continuous product development SALUS Controls plc reserve
the right to change specification, design and materials of products listed in this brochure
without prior notice.
Voltage free NO / COM terminals
868 MHz
B
A
Radio frequency
Dimension [mm]
Using UP or DOWN, set the day and
then press SELECT.
Using UP or DOWN, select the
week format.
Press SELECT to confirm.
Issue Date: 2020 V
V011
96 x 96 x 26 [mm]
| General | Details |
|---|---|
| Name | SALUS RT520 Programmable Thermostat User Guide |
| Make | SALUS |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.85 MB |

SALUS IT800 WIFI Smart Thermostat Installation Guide

SALUS 091FLRF Wireless Room Thermostat User Guide

SALUS Thermostat Sensor TS600 User Guide

SALUS Thermostat and Smart Plug Installation Guide

SALUS Programmable Wired Thermostat VS30W/VS30B Installation Guide

SALUS Wired Thermostat Installation Guide

SALUS Wired Digital Thermostat – Non-programmable HTRS230 User Manual

SALUS RT520 Radiator Thermostat User Guide

SALUS RT310 Thermostat User Manual

SALUS Thermostat RT520 User Manual

SALUS RT520 Programmable Thermostat User Guide Overview
Summary of Contents
- Page 1: Button functions include MENU, SELECT, UP, DOWN, ON, OFF, AUTO, MANUAL, and BOOST. The RT520 and RT520RF are the latest additions to SALUS’ RT range of thermostat heating controls, offering a cost-effective fully compliant Boiler Plus solution. OpenTherm Modulating Control allows the boiler's heat output to match the varying demand from the thermostat, enhancing system efficiency and comfort. Before use, it is important to read the manual carefully. The thermostat requires 2 x AA alkaline batteries for operation. Installation must be carried out by a qualified person in accordance with national and EU regulations. Safety information emphasizes using the device as intended and keeping it in dry conditions. The product complies with essential requirements of several EU Directives. The RT520 thermostat features a larger LCD display and additional operational functions. The receiver connections must be made and powered before inserting batteries into the thermostat.
- Page 2: Standard power up and configuration Landlord settings is a pin code protected feature that allows the landlord to set a service reminder on the thermostat. Optimum Stop calculates how long the house will take to cool down, then turns off the boiler at the earliest possible moment. During the pairing process, please make sure the thermostat and the receiver are at least 1 meter from each other. TPI (Time Proportional & Integral) is a self-learning, time-proportional algorithm that ensures economical system operation. The pairing process takes up to 10 minutes. Optimum Start is a selectable function which will start the boiler operation at the optimum time to achieve the set-point temperature. To reset the thermostat, press MENU, DOWN and BOOST simultaneously for 5 seconds. Once service mode has become active, the device will lock the set point temperature as set by the installer/landlord. The testing process takes up to 10 minutes.