ROOM THERMOSTAT PLACEMENT
ROOM THERMOSTAT WIRING DIAGRAM
ENGLISH
Room Thermostat needs to be placed in the room which is used most
frequently. For instance; living room or lounge. Placing the Room
Thermostat in a spot that have air circulation like entrance of a room
or side of window should be avoided. Also anywhere close to
heating/cooling units such as radiator, stove and spots which get
direct sun lights would not be suitable. Room Thermostat needs to be
located above the floor 150 cm height. Few trials may be made to find
themostconvenientspot.
HEATING/COOLING UNIT
DIGITAL ROOM THERMOSTAT
generallife.com.tr
SERIES:
MITRA, ARUNA, ILLONA, THERMA
HT220/HT220S/HT230S USER MANUAL
GENERAL SPECIFICATIONS
HT220/HT220S/HT230S is a wired room thermostat. The user can
adjust the room temperature with the required temperature and get
morecomfortable and economic heating/cooling.
NO COM
min. 20 cm
DIGITAL ROOM THERMOSTAT
Warning!
Operations within the heating
/
cooling unit or the electrical
installationmustbecarriedout byprofessionally qualified persons.
PreciseTemperatureMeasurement
Heatingcalibration
Heating/Cooling Modes
ON/OFFControl
WiredConnection
TPIAlgorithm
ROOM THERMOSTATTEMPERATURE CALIBRATION
Temperature sensors which are used in Room Thermostats are highly
sensitive. You may need to calibrate your Room Thermostat if you
would like to get the same temperature values with other
thermometersinyourliving space.
SERIES:
MITRA, ARUNA, ILLONA,
THERMA
HT220/HT220S/HT230S AND EQUIPMENTS
While your device is turned off, press and hold the button for 3
seconds.
Room Thermostat
Alkaline Battery
Dowels and Screws
Press the button until the “
” menu appers. In order to see the
HT220/HT220S/HT230S
USER MANUALS
desired temperature, set the temperature difference by turning the
button to right or left. This valuecan be arranged between “-8oC" and
“+8oC".
BATTERY PLACEMENT
Before starting, power off the device connected to the Room
Thermostatand makesurethattheenergy iscutoff.
To save the settings and exit, press the "On/Off" button until the
deviceturnsoff.
TECHNICAL DATA
Dimensions
Note:Recommended tempreturecalibrationis“0.0oC”.
85mm / 125mm / 24mm
Operating Current
Relay NO Switching Current
3V DC (2 x AAA alkaline battery)
2A/30VDC (Resistive load)
0.5A/125VAC (Resistive load)
0.1oC
ROOM THERMOSTAT HEATING / COOLING MODES
Your Room Thermostat has heating and cooling modes. In order to
switcheasilybetweenheating and cooling modes:
While your device is turned off, press and hold the button for 3
seconds.
Temperature Measurement
Accuracy
Operating Temperature Range
Battery Life
Operating Temperature
Storage Temperature
(5oC) – (30oC)
1 Year (2 x AAA)
(-10oC) – (+50oC)
(-20oC) – (+60oC)
Pressthebutton until the“
”menu appears.
” (heating) and “
You can switch between “
” (cooling) modes
”menu.
byturning thebutton torightorleftinthe“
To save the settings and exit, press the button until the device turns
off.
The settings you have made have been saved. Once you turned on
yourdevice, itwilloperatewiththechanged settings.
ROOM THERMOSTAT
1
As shown in the picture above, press the screwdriver forward from the
space shown, bend the tabs and separate the front cover. Insert 2 new
AAA alkaline batteries in the battery housing with the correct battery
direction. Replace both batteries at the same time. Then align the
front part of your Room Thermostat to the back and squeeze it
towards theback.
Low Battery Warning: When the “ ” icon appears on the screen, it
means “low battery warning”. It is recommended to replace the
batterieswhen thiswarning appears.
2
3
FACTORY SETTINGS RESET
You can reset your Room Thermostat to its default factory settings.
This operation resets the calibration setting and heating/cooling
modes to factory setting. To reset your Room Thermostat to factory
setting:
While your device is turned off, press and hold the button for 3
seconds.
4
5
6
Pressthebutton untilthe“
While in the “ “ menu, turn the button to right or left in order to
select“ “option and pressthebutton.
”menu appears.
Warning: When the product is not used for a long period (more than 15
days), remove the batteries. Otherwise, malfunctions that may occur
would beoutofwarranty.
1
2
Battery Indicator
Heating Indicator
- If the Heating Indicator is blinking, the heating unit is
Your devicewillbeturnedoff and resettofactorysettings.
Pleasethrowyourdead batteriesinto thewastebin forbatteries.
working.
- If the Heating Indicator is steady, the heating unit is not
working.
Cooling Indicator
- If the Cooling Indicator is blinking, the cooling unit is
working.
3
- If the Cooling Indicator is steady, the cooling unit is not
working.
Room Temperature
Set Temperature
ON/OFF and Temperature Setting Button
4
5
6
generallife.com.tr
2
1
3
| General | Details |
|---|---|
| Name | GENERAL LIFE HT220 Wired Room Thermostat User Manual |
| Make | GENERAL LIFE |
| Language | English |
| Filetype | PDF (Download) |
| File size | 1.85 MB |

GENERAL LIFE HT330S RF Room Thermostat User Manual

GENERAL LIFE FH103S Underfloor Heating Thermostat User Manual

GENERAL LIFE HT250 RF Digital Room Thermostat User Manual

GENERAL LIFE FH104S Underfloor Heating Thermostat User Manual

GENERAL LIFE ARUNA 302S Digital Room Thermostat User Manual

GENERAL LIFE FH250S Underfloor Heating Thermostat User Manual

GENERAL LIFE FC220 Digital Fan Coil Thermostat User Manual

GENERAL LIFE HT220S RF Digital Room Thermostat User Manual

GENERAL LIFE 270S RF Room Thermostat User Manual

GENERAL LIFE 270 Wireless Room Thermostat User Manual

GENERAL LIFE HT220 Wired Room Thermostat User Manual Overview
Summary of Contents
- Page 1: Room thermostat needs to be placed in the room which is used most frequently. Placing the room thermostat in a spot with poor air circulation should be avoided. Room thermostat needs to be located above the floor at a height of 150 cm. HT220/HT220S/HT230S is a wired room thermostat. Operations within the heating/cooling unit must be carried out by professionally qualified persons. Temperature sensors used in room thermostats are highly sensitive. Recommended temperature calibration is “0.0°C”. You can reset your room thermostat to its default factory settings. When the low battery icon appears, it is recommended to replace the batteries. If the heating indicator is blinking, the heating unit is working.
- Page 2: Warranty conditions state that the warranty period starts from the invoice date and covers manufacturing defects for 2 years. If the placement of the TPI Room Thermostats is changed or if they are de-energized, the learning process will restart and should be considered as 7 days. The TPI algorithm predicts temperature changes to maintain the set temperature with minimal deviations. Devices are delivered in working condition, and on-site commissioning incurs a service fee. Repairs under warranty are conducted at the company factory, with transportation costs borne by the customer for on-site services. Malfunctions caused by customer actions are not covered by the warranty, and customers must report any damages to maintain their warranty rights. Battery leakage and damages from using devices with other brands are not covered by the warranty. The warranty is void if devices are damaged by the customer or if malfunctions are caused by external factors like natural disasters. The maximum repair time is 20 working days, and if not repaired within this time, a similar product must be provided for use. Customers can appeal to consumer courts regarding warranty issues, and the warranty document must be retained throughout the warranty period.