Home > GENERAL LIFE > GENERAL LIFE 300S Smart Thermostat User Manual

GENERAL LIFE 300S Smart Thermostat User Manual

ROOM THERMOSTAT  
ButtonFunctions  
SMART RECEIVER SETUP  
ENGLISH  
For smart receiversetup, download the application fromApp Storeor Google Play  
or scan the QR code below with your smartphone. In this way, you will be able to  
download the mobile application from App Store or Google Play to your  
1
smartphone. (You may be required to have  
depending on thebrand and model of yourphone, for thisprocess.)  
a
QR code reader application  
SMART ROOM THERMOSTAT  
2
3
generallife.com.tr  
4
5
BATTERY PLACEMENT  
Click to download.  
6
THERMA 300S SMART USER MANUAL  
1
2
3
4
5
6
ON/OFF Button  
Temperature Adjustment Button (Increasing)  
Temperature Adjustment Button (Decreasing)  
Weekly Program Button  
WHAT IS A SMART ROOM THERMOSTAT?  
Complete the user registration process by opening the mobile application that  
youdownloaded.  
OpentheBluetooth fromyourmobile phone'ssettings.  
After you completed the user registration process, press the “+” button in the top-  
right corner of the main screen of the application, Press the receiver's Wi-Fi  
pairing button for 5seconds.  
TheLEDon thereceiverwillstart toblink green.  
Setup will begin with Bluetooth in the application. When the deviceis found, press  
theAddbutton.  
Uygulamada bluetooth ile kurulum başlayacaktır. Cihaz bulununca “Add”  
butonuna basınız.  
Press the “+” button near the W Modem device and press the “Next” button after  
makingsurethatyouenteredthecorrectWi-Fiinformation.  
Wait until the setup process is completed. When you saw the green approval  
symbol on theW Modem, presstheDonebutton in thetop-right corner.  
Pressthe screwdriverforward fromthe space at the bottom of the room thermostat,  
bend the tabs and separate the front cover. Insert 2 new AAA alkaline batteries in  
the battery housing with the correct battery direction. Replace both batteries at the  
same time. Align the front part of your room thermostat with the corresponding slot  
on theback, and thenpush gentlyuntil thethermostatsnaps intoplace.  
A
smart room thermostat is  
a
device that allows you to control your heating  
Settings Button  
Mode Button – Unlock Button  
equipment viaAPPwiththeinternetevenwhen youarenot athome.  
ProductDisplayLayout  
HOW DOES THERMA 300S SMART WORK?  
THERMA 300S SMART is a smart wireless room thermostat.You can control it with  
the mobile application after you pair your room thermostat with the receiver, and  
completetheinstallationofthesmartreceiver.  
1
9
Low Battery Warning: When the “  
” icon appears on the screen, it means “low  
10  
battery warning”. It is recommended to replace the batteries when this warning  
appears.  
Warning: When the product is not used for a long period (more than 15 days),  
remove the batteries. Otherwise, malfunctions that may occur would be out of  
warranty. Pleasethrowyourdead batteriesintothewastebin forbatteries.  
2
3
11  
WHAT ARE THE ADVANTAGES OF THERMA 300SSMART?  
4
You can control your home's temperature via its mobile application, no matter  
whereyouarein theworld.  
5
6
You caneasilycreatedailyand weeklyschedules viaitsmobile application.  
You can place the room thermostat anywhere in your home, thanks to its use with  
batteries.  
RECEIVER PLACEMENT  
7
8
The important things to note for the Receiver placement are  
avoiding physical contact between the receiver and the  
heating/cooling unit, and protectingitagainstmaterialssuch  
asliquid, dust, etc.  
It ensures that your living space stays at the desired temperature at any time. In  
this way, you can saveup to 30% on your bills by preventingyour heating unit from  
working unnecessarily.  
1
2
3
4
5
6
7
8
Day Indicator  
ROOM THERMOSTATTEMPERATURE CALIBRATION  
Hour Indicator  
Temperaturesensors which areused in room thermostatsarehighly sensitive.  
You may need to calibrate your room thermostat if you would like to get the same  
temperaturevaluesasotherthermometersin yourliving space.  
Key Lock  
Room Temperature  
Set Temperature  
Economy Mode  
Comfort Mode  
RULES THAT NEED TO BE OBSERVED FOR SAFETY  
The devices should be placed to minimize the damage to the received and  
transmittedsignals bypayingattentiontothefollowingpoints;  
While yourdeviceisturnedoff, presstheON/OFFbutton for3seconds.  
Press the "ON/OFF" button until the “ ” menu appears. To see the desired  
temperature, set the temperature difference by pressing the “Temperature  
AdjustmentButtons”. This valuecanbearrangedbetween-8°C" and “+8°C".  
To save the settings and exit, press the " ON/OFF " button until the device turns  
off.  
1-Besuretoreadtheusermanual beforeusing thedeviceand itsequipment.  
2- Opening, disassembly, or use of plastic parts of the product and equipment other  
thantheintended purpose areout of warranty.  
3- Please make sure that the sockets to which you connect your devices and  
equipment areattherecommendedvoltagevaluein theusermanual.  
4- Keep away and protect your product and its equipment from all kinds of external  
substancessuch asliquid, dust, heat, etc.  
5- Do not expose the device cables to any jamming and pressure. Take care to  
connectthedevices'energyconnection tothesocketsyoucanalwaysreach.  
6- Turn off the electrical power to prevent damage to your device and apparatus in  
caseof lightning and thunderstorms.  
Thedevicesshould not bemounted on metalsurfaces.  
Weekly Program Mode  
Cooling Indicator  
The devices should not be installed close to electrical cables and electronic  
equipment such ascomputersand televisionunits.  
9
- If the Cooling Indicator is blinking, the cooling unit is working.  
- If the Cooling Indicator is steady, the cooling unit is not working.  
Heating Indicator  
The devices should not be installed near large metal structures or other building  
materialsusing finemetalmeshessuch asspecialglassorspecialconcrete.  
Distance between the room thermostat and the Receiver should not exceed 20  
metersor2oors.  
Note: Recommended temperaturecalibrationis“0.0oC”.  
10  
11  
- If the Heating Indicator is blinking, the heating unit is working.  
- If the Heating Indicator is steady, the heating unit is not working.  
Battery Indicator  
ROOM THERMOSTAT HEATING/COOLING OPTION  
Your room thermostat has heating and cooling options. To switch easily between  
theheating and cooling options:  
Thereceivermustbeinstalledatleast50cmawayfromtheheating/cooling unit.  
Note: During active use of the room thermostat, the symbols indicated by 5, 6, 7, 8, 9  
and 10willnot appearon thescreen.  
While yourdeviceisturnedoff, pressand hold theON/OFFbutton for3seconds.  
PresstheON/OFFbutton until the menu appears.  
” (heating) and “ ” (cooling) options by using  
menu.  
To save the settings and exit, press the“ON / OFF” button until the device turns  
off.  
RECEIVER INSTALLATION  
7-Turn off theelectricalpowerwhen yourdeviceisnot used foralong time.  
8- Your devices and equipment should be used by paying attention to the matters  
stated in the user manual. In case of damage and malfunctions, arising from  
improper use (contact with liquid, falling to the ground, etc.) definitely ask for the  
installer'shelp.  
9- Call our service for maintenance and repair of THERMA 300S SMART and its  
equipment. Maintenance and repair of the device and equipment should be carried  
out only by the technical service of ISIPARK A.S. and its authorized services, spare  
parts, and accessoriesspecifiedbythecompany should beused.  
First, shut down your heating/cooling unit and your heating/cooling unit's power  
sourcewithallelectricalcurrent(fuse, socket, etc.)  
As shown in the connection diagram, connect one end of the heating/cooling unit  
connection cabletotheCOMand theothertotheNOinput of thereceiver.  
Connect the other ends of the cable -which you connected to the receiver- to the  
room thermostat connection terminal as shown in your heating/cooling unit's  
usermanual.  
RECEIVER  
You can switch between “  
theUpor"Down"buttons in the“  
1-Manual Operation Button:  
Deactivates the receiver and allows users to  
manually use the heating/cooling unit.  
2-Wi-Fi Pairing Button:  
1
2
The settings you have made have been saved. Once you turned on your device, it  
willoperatewiththechanged settings.  
3
Makes the receiver ready for smart installation.  
3-Receiver LED Light  
You must first connect the receiver power cable to the receiver and then to the  
fuse towhich theheating/cooling unit isconnected.  
After completing the cable connection process, first, turn on your fuse and then  
yourheating/cooling unit.  
Finish the installation of the room thermostat to pair the receiver with the room  
thermostat.  
ROOM THERMOSTAT HYSTERESIS POSITIVE MENU  
4-Receiver Power Cable Input  
The hysteresis positive factory setting of your room thermostat is 0.5°C. This value  
may be adjusted between “0.1°C” and “2.0°C”. While the hysteresis positive value is  
0.5°C, if the room temperature goes above 0.5°C of the set temperature, your room  
thermostat will send a signal to your heating/cooling unit. For instance, when you  
set your room thermostat to 22.0°C, if the room temperature goes above 22.5°C, on  
the heating mode your heating unit will stop working; on the cooling mode your  
cooling unit willstart working. Tochange thehysteresispositivesetting:  
5-Heating/Cooling Unit Connection Cable Input  
THERMA 300S SMARTand EQUIPMENT  
THERMA 300S SMART  
Room Thermostat  
Holder Alkaline  
Battery  
Receiver  
Dowels and  
Screws  
AC  
RECEIVER WIRING DIAGRAM  
4
5
COM  
NO  
(230V)  
While yourdeviceisturnedoff, pressand hold theON/OFFbutton for3seconds.  
PresstheON/OFFbutton until the menu appears.  
RECEIVER LED DESCRIPTIONS  
Blinking Red  
The receiver did not get any signal from the heating/  
cooling unit for 22 minutes or longer and the heating/  
cooling unit has shut down.  
Waiting for a pairing signal from the room thermostat.  
The receiver and the room thermostat have been paired.  
Smart installation has not been completed.  
The receiver is in Bluetooth searching mode.  
Smart installation has been completed.  
The heating/cooling unit is not working.  
The heating/cooling unit is working.  
Shut the heating/cooling unit down signal has reached  
the receiver.  
Operate the heating/cooling unit signal has reached the  
receiver.  
Adjusttheoperating sensitivitybyusing theUpand “Downbuttons in the“  
hysteresispositivemenu.  
TECHNICAL DATA  
Room Thermostat  
Fast Blinking Red  
Steady Red  
To savethesettingsand exit, pressthe"ON/OFF"button until thedeviceturnsoff.  
Changes have been saved. Your room thermostat will be working with set  
operating sensitivitywhen youopen yourdevice.  
Dimensions (H/L/W)  
100mm / 160mm / 18.2mm  
3V DC (2 x AAA Alkaline Battery)  
0.1oC  
Operating Current  
Blinking Green  
Steady Green  
Temperature Measurement Accuracy  
Operating Sensitivity  
Operating Temperature Range  
Battery Life  
Operating Temperature  
Storage Temperature  
(-2.0oC) – (+2.0oC)  
ROOM THERMOSTAT HYSTERESIS NEGATIVE MENU  
(5oC) – (40oC)  
Steady Turquoise  
3 Short Red Blinking  
The hysteresis negative factory setting of your room thermostat is -0.5°C. This  
value may be adjusted between “-0.1°C” and “-2.0°C”. While the hysteresis negative  
value is -0.5°C, if the room temperature goes below 0.5°C of the set temperature,  
your room thermostat will send a signal to your heating/cooling unit. For instance,  
when you set your room thermostat to 22°C, if the room temperature goes below  
21.5°C, on the heating mode your heating unit will start working; on the cooling  
mode your cooling unit will stop working. To change the hysteresis negative  
setting:  
HEATING/COOLING UNIT  
1 Year (2 x AAA)  
(-10oC) – (+50oC)  
(-20oC) – (+60oC)  
Warning! Operations within the heating/cooling unit or the electrical installation  
mustbecarriedout byprofessionally qualified persons.  
3 Short Green Blinking  
Receiver  
Blinking Red and Green The heating/cooling unit is working in manual mode.  
PAIRING THE ROOM THERMOSTAT WITH THE RECEIVER  
Dimensions (H/L/W)  
90mm / 90mm / 25mm  
230V AC  
7A (240VAC – Resistive Load)  
10A (120VAC – Resistive Load)  
(-20oC) – (+60oC)  
To pair the room thermostat with the receiver, press the “Manual Operation  
Button” and “Wi-Fi Pairing Button” together at the same time and see the  
receiver'sfastblinking redLED.  
Operating Current  
ROOM THERMOSTAT PLACEMENT  
Relay NO Switching Current  
The room thermostat needs to be placed in the room which is used most frequently.  
For instance; the living room or lounge. Placing the room thermostat in a spot that  
has air circulation like the entrance of a room or the side of the window should be  
avoided. Also anywhereclose to heating/cooling units such as a radiator, stove, and  
spots that get directsun lights would not be suitable. The roomthermostat needs to  
be located abovethe floor 150 cm in height. Few trials may be made to find the most  
convenientspot.  
While yourdeviceisturnedoff, pressand hold theON/OFFbutton for3seconds.  
PresstheON/OFFbutton until the menu appears.  
Storage Temperature  
PresstheON/OFFbutton for3seconds whileyourdeviceisturned off.  
PresstheON/OFFbutton until“  
Press your room thermostat's “Up” or “Down“ button while the LED is fast blinking  
red.  
Adjusttheoperating sensitivitybyusing theUpand “Downbuttons in the“  
hysteresisnegativemenu.  
thepairing menu appears.  
To savethesettingsand exit, pressthe"ON/OFF"button until thedeviceturnsoff.  
Changes have been saved. Your room thermostat will be working with set  
operating sensitivitywhen youopen yourdevice.  
Ifthepairing issuccessful, thefastredashing LEDon thereceiverwillbesteady.  
Thereceiverand room thermostathavebeen pairedwitheachother.  
1
2
3
4
GeneralDetails
NameGENERAL LIFE 300S Smart Thermostat User Manual
MakeGENERAL LIFE
LanguageEnglish
FiletypePDF (Download)
File size2.11 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
GENERAL LIFE HT330S RF Room Thermostat User Manual
GENERAL LIFE HT330S RF Room Thermostat User Manual
GENERAL LIFE FH103S Underfloor Heating Thermostat User Manual
GENERAL LIFE FH103S Underfloor Heating Thermostat User Manual
GENERAL LIFE HT250 RF Digital Room Thermostat User Manual
GENERAL LIFE HT250 RF Digital Room Thermostat User Manual
GENERAL LIFE FH104S Underfloor Heating Thermostat User Manual
GENERAL LIFE FH104S Underfloor Heating Thermostat User Manual
GENERAL LIFE ARUNA 302S Digital Room Thermostat User Manual
GENERAL LIFE ARUNA 302S Digital Room Thermostat User Manual
GENERAL LIFE FH250S Underfloor Heating Thermostat User Manual
GENERAL LIFE FH250S Underfloor Heating Thermostat User Manual
GENERAL LIFE FC220 Digital Fan Coil Thermostat User Manual
GENERAL LIFE FC220 Digital Fan Coil Thermostat User Manual
GENERAL LIFE HT220S RF Digital Room Thermostat User Manual
GENERAL LIFE HT220S RF Digital Room Thermostat User Manual
GENERAL LIFE 270S RF Room Thermostat User Manual
GENERAL LIFE 270S RF Room Thermostat User Manual
GENERAL LIFE 270 Wireless Room Thermostat User Manual
GENERAL LIFE 270 Wireless Room Thermostat User Manual

GENERAL LIFE 300S Smart Thermostat User Manual
Get the free PDF manual for the GENERAL LIFE 300S Smart Thermostat User Manual and access setup steps, usage instructions, and troubleshooting tips. 👉 View online or download now to keep your thermostat running smoothly!

GENERAL LIFE 300S Smart Thermostat User Manual Overview

Summary of Contents

  • Page 1: room thermostat For smart receiver setup, download the application from App Store or Google Play. A smart room thermostat is a device that allows you to control your heating equipment via an app with the internet even when you are not at home. Complete the user registration process by opening the mobile application that you downloaded. Low battery warning: When the icon appears on the screen, it means low battery warning. You can control your home's temperature via its mobile application, no matter where you are in the world. You can easily create daily and weekly schedules via its mobile application. The important things to note for the receiver placement are avoiding physical contact between the receiver and the heating/cooling unit. Temperature sensors used in room thermostats are highly sensitive. The devices should not be installed close to electrical cables and electronic equipment such as computers and television units. To pair the room thermostat with the receiver, press the “Manual Operation Button” and “Wi-Fi Pairing Button” together at the same time.
  • Page 2: Open window detection feature When the product is not used for a long period (more than 15 days), remove the batteries. Damages that may occur during the transportation of devices and apparatus are not covered by the warranty. Damages caused by mains voltage or faulty electrical installation are not covered by the warranty. Devices and apparatuses are out of warranty for malfunctions caused by force majeure such as fire, flood, earthquake, etc. All of the devices and apparatuses, including all their parts, are under the warranty of our company. In case of malfunction of the devices and apparatuses within the warranty period, the time spent during the repairment period is added to the warranty period. Your room thermostat measures sudden temperature changes in your house with its open window detection feature and prevents unnecessary energy consumption by turning off the heating/cooling unit. Your room thermostat takes the average room temperature of the last 40 seconds as the basis. The product manufactured by ISIPARK is connected wirelessly at 2.4 GHz internet and periodically shares the temperature and status information with the server.