Home > GENERAL > GENERAL ARUNA 301S Digital Room Thermostat User Manual

GENERAL ARUNA 301S Digital Room Thermostat User Manual

ProductDisplayLayout  
MODE SETTING  
As shown in the picture above, press the screwdriverforward from the space  
shown, bend the tabs and separate the front cover. Insert 2 new AAA alkaline  
batteries in the battery housing with the correct battery direction. Replace  
both batteries at the same time. Then align the front part of your Room  
Thermostatto thebackand squeezeittowards theback.  
ENGLISH  
MODES  
7
8
1
2
PRESET MODES  
WEEKLY  
PROGRAM  
MODE  
MANUAL MODE  
DIGITAL ROOM THERMOSTAT  
Low Battery Warning: When the “ ” icon appears on the screen, it means  
“low battery warning”. It is recommended to replace the batteries when this  
warning appears.  
generallife.com.tr  
9
10  
11  
3
Comfort  
Mode  
Economy  
Mode  
Holiday  
Mode  
4
5
6
Warning: When the product is not used for a long period (more than 15 days),  
remove the batteries. Otherwise, malfunctions that may occur would be out of  
warranty.  
Your Room Thermostat has  
5
different modes.  
3
of them (Comfort,  
ARUNA 301S USER MANUAL  
Economy and Holiday Mode) are preset modes. Other modes are manual  
mode and weeklyprogram mode.  
Please throwyour dead batteries into thewaste bin forbatteries.  
In preset modes, temperature values are based on user's choices which  
have been set in the beginning. Manual mode allows the Room Thermostat  
to operate within the temperature which is required and set directly by user.  
Weekly Program mode continues to work according to the weekly schedule  
determined bytheuser.  
GENERAL SPECIFICATIONS  
ARUNA 301S is  
1
2
3
4
5
6
7
8
9
Hour Indicator  
a
wired room thermostat. The user can get more  
Room Temperature  
Economy Mode  
Comfort Mode  
ROOM THERMOSTAT WIRING DIAGRAM  
comfortable and economic heating/cooling by adjusting the room  
thermostatwiththerequired temperature.  
HEATING/COOLING UNIT  
Dailyand WeeklyProgramming  
Holiday Mode  
In order to change thetemperaturevaluesof presetmodes:  
Different Mode Options (Comfort, Economy, Holiday)  
Weekly Program Mode  
Day Indicator  
Battery Indicator  
Press and hold the “Mode” button for  
Thermostatis on.  
3
seconds while your Room  
Heating Calibration  
ON/OFFControl  
Wired Connection  
Heating/Cooling Option  
TPIAlgorithm  
Comfort Mode temperature value will appear. You may adjust the  
temperature value of Comfort Mode by pressing the “Up” and “Down”  
buttons.  
Set Temperature  
Heating Indicator  
PreciseTemperatureMeasurement  
- If the Heating Indicator is blinking, the heating unit is  
working.  
- If the Heating Indicator is steady, the heating unit is not  
ARUNA 301S and EQUIPMENTS  
NO COM  
When setting is done, you may adjust the temperature value of Economy  
Mode with the “Up” and “Down” buttons by pressing the “Mode” button  
again.  
10  
11  
Dowels and Screws  
ARUNA 301S  
Room Thermostat  
Alkaline Battery  
working.  
Cooling Indicator  
Warning!  
Operations within the heating / cooling unit or the electrical installation  
must be carriedout byprofessionally qualified persons.  
You mayexitthesetting screen bypressing theModebutton 3 seconds.  
In order to change the manual mode temperature, press the “Up” or  
“Down” button while in the main screen. The Room Thermostat will switch  
to Manual Mode once pressedthe“Up” or “Downbutton.  
You maypresstheModebutton to switchto theother modes.  
- If the Cooling Indicator is blinking, the cooling unit is  
working.  
- If the Cooling Indicator is steady, the cooling unit is not  
working.  
ROOM THERMOSTATTEMPERATURE CALIBRATION  
Temperature sensors which are used in Room Thermostats are highly  
sensitive. You mayneed to calibrate yourRoom Thermostat if youwould like  
to get the same temperature values with other thermometers in your living  
space.  
TECHNICAL DATA  
ROOM THERMOSTAT PLACEMENT  
WEEKLY PROGRAM  
Room Thermostat needs to be placed in the room which is used most  
frequently. For instance; living room or lounge. Placing the Room  
Thermostat in a spot that have air circulation like entrance of a room or side  
of window should be avoided. Also anywhere close to heating/cooling units  
such as radiator, stove and spots which get direct sun lights would not be  
suitable. Room Thermostat needs to be located above the floor 150 cm  
height. Fewtrialsmaybe made to find themost convenientspot.  
Dimensions  
Operating Current  
Relay NO Switching Current  
85mm / 125mm / 20mm  
You may set the operating schedule of your Room Thermostat with weekly  
program mode. 7 different temperature values can be set for each day in  
weekly programming. These values can be set in temperature adjustment  
screens '' P0-P6''.  
3V DC (2 x AAA alkaline battery)  
2A/30VDC (Resistive load)  
0.5A/125VAC (Resistive load)  
While your device is turned off, press and hold the “On/Off“ button for 3  
seconds.  
Temperature Measurement Accuracy 0.1oC  
Press the "On/Off" button until the “  
” menu appears. In order to see  
In order to set the weekly schedule, press and hold the “Weekly Program“  
button for 3 seconds while your Room Thermostat is on. The “Hour,  
Minute and Day” setting will appear. Press the “Heating & Cooling Option”  
button untilthe“WeeklyProgrammenu (P0)appears.  
Operating Temperature Range  
Battery Life  
(5oC) – (30oC)  
the desired temperature, set the temperature difference by pressing the  
“Temperature Adjustment Buttons”. This value can be arranged between  
“-8°C" and “+8° C".  
1 Year (2 x AAA)  
(-10oC) – (+50oC)  
(-20oC) – (+60oC)  
Operating Temperature  
Storage Temperature  
In order to save the settings and exit, press the "On/Off" button until the  
deviceturns off.  
Days of the week will be blinking on the screen. You can initiate the weekly  
program setting if you wish to set the same schedule for every day of the  
week.  
min. 20 cm  
Note:Recommended temperature calibration is “0.0°C”.  
ROOM THERMOSTAT  
ButtonFunctions  
Press the “Up“ button once if you wish to set the same schedule for the  
weekdays. Firstvedaysof weekwill be blinking on thescreen.  
Press the “Up“ button once more if you wish to set the same schedule only  
for theweekend. Lasttwodaysof theweekwill be blinking on thescreen.  
Press the “Up“ button one more time if you wish to set the same schedule  
for every day of the week. 1st day of the week will be blinking on the  
screen. You can switch between the days by pressing the “Up“ button.  
Press theDownbutton in order to switchto thepreviousday.  
Press theWeeklyProgrambutton once to setaschedule.  
“P0” will be blinking on the screen. Set the temperature value of “P0” by  
pressing the “Weekly Programbutton once more. The hour setting of “P0”  
cannot be changed since it's factory setting.  
FACTORY SETTINGS RESET  
You can reset your Room Thermostat to its default factory settings. This  
operation resets the mode temperature values, calibration setting and  
heating/cooling modes to factory setting. In order to reset your Room  
Thermostatto factory setting:  
While your device is turned off, press and hold the “On/Off” button for 3  
seconds.  
PresstheOn/Off” button untilthe“  
While in the “ ” menu, select the “  
“Downbuttons and presstheOn/Off” button.  
Your devicewill be turned off and resetto factory settings.  
” menu appears.  
” option by using the “Up” or  
1
2
3
4
5
6
Press the “Weekly Program” button again. Day indicator will be blinking. If  
you will not change the day, press the “Weekly Program” button again and  
switchto theP1” settingbypressing theUp” button.  
DAY AND HOUR SETTINGS  
BATTERY PLACEMENT  
Before starting, power off the device connected to the Room Thermostat  
and makesurethatthe energy is cut off.  
While your Room Thermostat is on, keep pressing the “Weekly Program”  
button for 3 seconds.  
1
2
3
4
5
6
On/Off Button  
Heating & Cooling Option  
Weekly Program Button  
First, hour setting will appear on the screen. Once you complete the hour  
setting, adjust the minute setting by pressing the “Weekly Program”  
button. After the minute setting, press the “Weekly Program” button to set  
thetemperaturevalue.  
At the first screen that appears, hour part will be blinking. You may set the  
timewiththeUpandDownbuttons.  
Temperature Adjustment Button (To Decrease)  
Temperature Adjustment Button (To Increase)  
Mode Button  
After setting the time, the “Heating & Cooling Optionbutton needs to be  
pressed once. For minute setting, minute part will be blinking. You mayset  
theminute withtheUpandDownbuttons.  
Follow thesamesteps for other schedule settings.  
Once all changes made, press and hold the “Weekly Program” button for 3  
seconds to save.  
After setting the minute, the “Heating & Cooling Optionbutton needs to  
be pressed once to setthe dayof theweek.  
Mondayhas setasthe firstdayof the weekand indicated withnumber1".  
Numbers indicate the following days respectively 2-Tuesday, 3-  
Wednesday, 4-Thursday, 5-Friday, 6-Saturdayand 7-Sunday  
When setting is done, you may exit by pressing the “Weekly Program”  
button for 3 seconds.  
Note: In order to check the weekly schedule which has been set without  
making any changes, press the “Weekly Program” button once while your  
Room Thermostat is on. Press the “Up” and “Down” buttons to see the days,  
pressthe “Modebutton to seethesettingsbetweenP0-P6”.  
1
2
3
4
GeneralDetails
NameGENERAL ARUNA 301S Digital Room Thermostat User Manual
MakeGENERAL
LanguageEnglish
FiletypePDF (Download)
File size2.11 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
GENERAL ARUNA 300S Smart Room Thermostat User Manual
GENERAL ARUNA 300S Smart Room Thermostat User Manual
GENERAL HT250S Digital Room Thermostat User Manual
GENERAL HT250S Digital Room Thermostat User Manual
GENERAL FH260S Underfloor Heating Thermostat User Manual
GENERAL FH260S Underfloor Heating Thermostat User Manual
GENERAL HT100S Digital Room Thermostat User Manual
GENERAL HT100S Digital Room Thermostat User Manual
GENERAL SOLARA 330S SMART Smart Room Thermostat User Manual
GENERAL SOLARA 330S SMART Smart Room Thermostat User Manual
GENERAL HT250 Digital Room Thermostat User Manual
GENERAL HT250 Digital Room Thermostat User Manual
GENERAL SENNA 300 Digital Room Thermostat User Manual
GENERAL SENNA 300 Digital Room Thermostat User Manual
GENERAL ARUNA 300S RF Digital Room Thermostat User Manual
GENERAL ARUNA 300S RF Digital Room Thermostat User Manual
GENERAL SENNA 300 Smart Room Thermostat User Manual
GENERAL SENNA 300 Smart Room Thermostat User Manual
GENERAL MITRA 250S Digital Room Thermostat User Manual
GENERAL MITRA 250S Digital Room Thermostat User Manual

GENERAL ARUNA 301S Digital Room Thermostat User Manual
Get the free PDF manual for the GENERAL ARUNA 301S Digital Room Thermostat User Manual and access setup steps, usage instructions, and troubleshooting tips. 👉 View online or download now to keep your thermostat running smoothly!

GENERAL ARUNA 301S Digital Room Thermostat User Manual Overview

Summary of Contents

  • Page 1: Product display layout Mode setting Insert 2 new AAA alkaline batteries in the battery housing with the correct battery direction. Your Room Thermostat has 5 different modes. Comfort, Economy, and Holiday Mode are preset modes. Manual mode allows the Room Thermostat to operate within the temperature set directly by the user. Weekly Program mode continues to work according to the weekly schedule determined by the user. Low battery warning: When the icon appears on the screen, it means low battery warning. When the product is not used for a long period, remove the batteries. Room Thermostat needs to be placed in the room which is used most frequently.
  • Page 2: TPI room thermostat working logic Your room thermostat works with the TPI algorithm, predicting temperature changes to maintain your set temperature with minimal deviation. If the placement of the TPI room thermostats is changed, the learning process will restart and should be considered as 7 days. TPI technology ensures the best possible energy efficiency from your heating/cooling system. Malfunctions resulting from the use of devices contrary to the user manual are not covered by the warranty. The warranty period starts from the invoice date and covers manufacturing defects for 5 years. In case of malfunctioning devices, testing is conducted to determine if the fault is due to customer or manufacturer error. The connection between your room thermostat and heating/cooling unit should be made by professionally qualified persons. The TPI algorithm creates a general temperature map of your home, learning how to maintain the desired temperature efficiently. Damages caused by mains voltage or faulty electrical installation are not covered by the warranty. The warranty document must be kept by the customer during the warranty period; a second document will not be issued if lost.