MODESETTING
As shown in the picture above, press the screwdriverforward from the space
shown, bend the tabs and separate the front cover. Insert 2 new AAA alkaline
batteries in the battery housing with the correct battery direction. Replace
both batteries at the same time. Then align the front part of your Room
Thermostatto thebackand squeezeittowards theback.
ENGLISH
MODES
7
8
1
2
PRESET MODES
WEEKLY
PROGRAM
MODE
MANUAL MODE
DIGITAL ROOM THERMOSTAT
Low Battery Warning: When the “ ” icon appears on the screen, it means
“low battery warning”. It is recommended to replace the batteries when this
warning appears.
generallife.com.tr
9
10
11
3
Comfort
Mode
Economy
Mode
Holiday
Mode
4
5
6
Warning: When the product is not used for a long period (more than 15 days),
remove the batteries. Otherwise, malfunctions that may occur would be out of
warranty.
Your Room Thermostat has
5
different modes.
3
of them (Comfort,
ARUNA 301S USER MANUAL
Economy and Holiday Mode) are preset modes. Other modes are manual
mode and weeklyprogram mode.
Pleasethrowyourdead batteries into thewastebin forbatteries.
In preset modes, temperature values are based on user's choices which
have been set in the beginning. Manual mode allows the Room Thermostat
to operate within the temperature which is required and set directly by user.
Weekly Program mode continues to work according to the weekly schedule
determined bytheuser.
GENERALSPECIFICATIONS
ARUNA 301S is
1
2
3
4
5
6
7
8
9
Hour Indicator
a
wired room thermostat. The user can get more
Room Temperature
Economy Mode
Comfort Mode
ROOMTHERMOSTATWIRINGDIAGRAM
comfortable and economic heating/cooling by adjusting the room
thermostatwiththerequired temperature.
HEATING/COOLING UNIT
Dailyand WeeklyProgramming
Holiday Mode
In order to change thetemperaturevaluesof presetmodes:
DifferentMode Options (Comfort, Economy, Holiday)
Weekly Program Mode
Day Indicator
Battery Indicator
Press and hold the “Mode” button for
Thermostatis on.
3
seconds while your Room
Heating Calibration
ON/OFFControl
Wired Connection
Heating/Cooling Option
TPIAlgorithm
Comfort Mode temperature value will appear. You may adjust the
temperature value of Comfort Mode by pressing the “Up” and “Down”
buttons.
Set Temperature
Heating Indicator
PreciseTemperatureMeasurement
- If the Heating Indicator is blinking, the heating unit is
working.
- If the Heating Indicator is steady, the heating unit is not
ARUNA 301Sand EQUIPMENTS
NO COM
When setting is done, you may adjust the temperature value of Economy
Mode with the “Up” and “Down” buttons by pressing the “Mode” button
again.
10
11
Dowels and Screws
ARUNA 301S
Room Thermostat
Alkaline Battery
working.
Cooling Indicator
Warning!
Operations within the heating / cooling unit or the electrical installation
must be carriedout byprofessionally qualified persons.
You mayexitthesetting screen bypressing the“Mode”button 3 seconds.
In order to change the manual mode temperature, press the “Up” or
“Down” button while in the main screen. The Room Thermostat will switch
to ManualMode once pressedthe“Up” or “Down”button.
You maypressthe“Mode”button to switchto theother modes.
- If the Cooling Indicator is blinking, the cooling unit is
working.
- If the Cooling Indicator is steady, the cooling unit is not
working.
ROOMTHERMOSTATTEMPERATURECALIBRATION
Temperature sensors which are used in Room Thermostats are highly
sensitive. You mayneed to calibrate yourRoom Thermostat if youwould like
to get the same temperature values with other thermometers in your living
space.
TECHNICALDATA
ROOMTHERMOSTATPLACEMENT
WEEKLY PROGRAM
Room Thermostat needs to be placed in the room which is used most
frequently. For instance; living room or lounge. Placing the Room
Thermostat in a spot that have air circulation like entrance of a room or side
of window should be avoided. Also anywhere close to heating/cooling units
such as radiator, stove and spots which get direct sun lights would not be
suitable. Room Thermostat needs to be located above the floor 150 cm
height. Fewtrialsmaybe made to find themost convenientspot.
Dimensions
Operating Current
Relay NO Switching Current
85mm / 125mm / 20mm
You may set the operating schedule of your Room Thermostat with weekly
program mode. 7 different temperature values can be set for each day in
weekly programming. These values can be set in temperature adjustment
screens '' P0-P6''.
3V DC (2 x AAA alkaline battery)
2A/30VDC (Resistive load)
0.5A/125VAC (Resistive load)
While your device is turned off, press and hold the “On/Off“ button for 3
seconds.
Temperature Measurement Accuracy 0.1oC
Press the "On/Off" button until the “
” menu appears. In order to see
In order to set the weekly schedule, press and hold the “Weekly Program“
button for 3 seconds while your Room Thermostat is on. The “Hour,
Minute and Day” setting will appear. Press the “Heating & Cooling Option”
button untilthe“WeeklyProgram”menu (P0)appears.
Operating Temperature Range
Battery Life
(5oC) – (30oC)
the desired temperature, set the temperature difference by pressing the
“Temperature Adjustment Buttons”. This value can be arranged between
“-8°C" and “+8° C".
1 Year (2 x AAA)
(-10oC) – (+50oC)
(-20oC) – (+60oC)
Operating Temperature
Storage Temperature
In order to save the settings and exit, press the "On/Off" button until the
deviceturns off.
Days of the week will be blinking on the screen. You can initiate the weekly
program setting if you wish to set the same schedule for every day of the
week.
min. 20 cm
Note:Recommended temperaturecalibration is “0.0°C”.
ROOMTHERMOSTAT
ButtonFunctions
Press the “Up“ button once if you wish to set the same schedule for the
weekdays. Firstfivedaysof weekwill be blinking on thescreen.
Press the “Up“ button once more if you wish to set the same schedule only
for theweekend. Lasttwodaysof theweekwill be blinking on thescreen.
Press the “Up“ button one more time if you wish to set the same schedule
for every day of the week. 1st day of the week will be blinking on the
screen. You can switch between the days by pressing the “Up“ button.
Press the“Down“button in order to switchto thepreviousday.
Press the“WeeklyProgram“button once to setaschedule.
“P0” will be blinking on the screen. Set the temperature value of “P0” by
pressing the “Weekly Program“button once more. The hour setting of “P0”
cannot be changed since it's factory setting.
FACTORY SETTINGS RESET
You can reset your Room Thermostat to its default factory settings. This
operation resets the mode temperature values, calibration setting and
heating/cooling modes to factory setting. In order to reset your Room
Thermostatto factory setting:
While your device is turned off, press and hold the “On/Off” button for 3
seconds.
Pressthe“On/Off” button untilthe“
While in the “ ” menu, select the “
“Down”buttons and pressthe“On/Off” button.
Your devicewill be turned off and resetto factory settings.
” menu appears.
” option by using the “Up” or
1
2
3
4
5
6
Press the “Weekly Program” button again. Day indicator will be blinking. If
you will not change the day, press the “Weekly Program” button again and
switchto the“P1” settingbypressing the“Up” button.
DAY AND HOURSETTINGS
BATTERY PLACEMENT
Before starting, power off the device connected to the Room Thermostat
and makesurethattheenergy is cutoff.
While your Room Thermostat is on, keep pressing the “Weekly Program”
button for 3 seconds.
1
2
3
4
5
6
On/Off Button
Heating & Cooling Option
Weekly Program Button
First, hour setting will appear on the screen. Once you complete the hour
setting, adjust the minute setting by pressing the “Weekly Program”
button. After the minute setting, press the “Weekly Program” button to set
thetemperaturevalue.
At the first screen that appears, hour part will be blinking. You may set the
timewiththe“Up” and“Down” buttons.
Temperature Adjustment Button (To Decrease)
Temperature Adjustment Button (To Increase)
Mode Button
After setting the time, the “Heating & Cooling Option” button needs to be
pressed once. For minute setting, minute part will be blinking. You mayset
theminute withthe“Up” and“Down” buttons.
Follow thesamesteps for other schedule settings.
Once all changes made, press and hold the “Weekly Program” button for 3
seconds to save.
After setting the minute, the “Heating & Cooling Option” button needs to
be pressed once to setthedayof theweek.
Mondayhas setasthefirstdayof theweekand indicated withnumber“1".
Numbers indicate the following days respectively 2-Tuesday, 3-
Wednesday, 4-Thursday, 5-Friday, 6-Saturdayand 7-Sunday
When setting is done, you may exit by pressing the “Weekly Program”
button for 3 seconds.
Note: In order to check the weekly schedule which has been set without
making any changes, press the “Weekly Program” button once while your
Room Thermostat is on. Press the “Up” and “Down” buttons to see the days,
press the“Mode”button to seethesettingsbetween“P0-P6”.
1
2
3
4
| General | Details |
|---|---|
| Name | GENERAL LIFE ARUNA 301S Digital Room Thermostat User Manual |
| Make | GENERAL LIFE |
| Language | English |
| Filetype | PDF (Download) |
| File size | 2.05 MB |

GENERAL LIFE HT330S RF Room Thermostat User Manual

GENERAL LIFE FH103S Underfloor Heating Thermostat User Manual

GENERAL LIFE HT250 RF Digital Room Thermostat User Manual

GENERAL LIFE FH104S Underfloor Heating Thermostat User Manual

GENERAL LIFE ARUNA 302S Digital Room Thermostat User Manual

GENERAL LIFE FH250S Underfloor Heating Thermostat User Manual

GENERAL LIFE FC220 Digital Fan Coil Thermostat User Manual

GENERAL LIFE 270S RF Room Thermostat User Manual

GENERAL LIFE 270 Wireless Room Thermostat User Manual

GENERAL LIFE HT220S RF Digital Room Thermostat User Manual

GENERAL LIFE ARUNA 301S Digital Room Thermostat User Manual Overview
Summary of Contents
- Page 1: Product display layout Mode setting Insert 2 new AAA alkaline batteries in the battery housing with the correct battery direction. Low battery warning: When the icon appears on the screen, it means low battery warning. Your Room Thermostat has 5 different modes. In preset modes, temperature values are based on user's choices. Manual mode allows the Room Thermostat to operate within the temperature set directly by the user. Weekly program mode continues to work according to the weekly schedule determined by the user. Room Thermostat needs to be placed in the room which is used most frequently. You may set the operating schedule of your Room Thermostat with weekly program mode.
- Page 2: What to know about TPI room thermostat Your room thermostat works with the TPI algorithm. TPI technology predicts when the temperature will rise or fall and adjusts heating/cooling accordingly. If the placement of the TPI room thermostats is changed, the learning process will restart. Malfunctions caused by customer misuse are not covered by the warranty. The warranty period starts from the invoice date and lasts for 5 years. The warranty document must be kept by the customer during the warranty period. Devices and apparatus are delivered in working condition. The maintenance of devices and apparatus is done in our company. Isıpark reserves the rights to change product specifications and user manuals.