ROOM THERMOSTAT
ButtonFunctions
BATTERY PLACEMENT
SMART RECEIVER SETUP
ENGLISH
For smart receiver setup, download the Smart Life application from App Store or
Google Play or scan the QR code below with your smartphone. In this way, you will
be able to download the Smart Life mobile application from App Store or Google
1
2
3
4
5
6
SMART ROOM THERMOSTAT
Play to your smartphone. (You may be required to have
a
QR code reader
application depending on thebrand and model of yourphone, for this process.)
generallife.com.tr
HT330S SMART USER MANUAL
1
2
3
4
5
6
Weekly Program Button
Heating & Cooling Option
Mode Button
Temperature Adjustment Button (To Increase)
Temperature Adjustment Button (To Decrease)
On/Off Button – Unlock Button
WHAT IS A SMART ROOM THERMOSTAT?
A
Pressthe screwdriverforward fromthe space at the bottom of the room thermostat,
bend the tabs and separate the front cover. Insert 2 new AAA alkaline batteries in
the battery housing with the correct battery direction. Replace both batteries at the
same time. Align the front part of your room thermostat with the corresponding slot
on theback, and then push gently until thethermostatsnaps into place.
smart room thermostat is
a
device that allows you to control your heating
equipment viaAPPwiththeinternetevenwhen youarenot athome.
Complete the user registration process by opening the mobile application that
youdownloaded.
ProductDisplayLayout
HOW DOES HT330S SMART WORK?
Open theBluetooth fromyourmobile phone's settings.
After you completed the user registration process, press the “+” button in the top-
right corner of the main screen of the application, Press the receiver's Wi-Fi
pairing button for 5 seconds.
HT330S SMART is a smart wireless room thermostat. You can control it with the
mobile application after you pair your room thermostat with the receiver, and
completetheinstallationofthesmartreceiver.
Low Battery Warning: When the “ ” icon appears on the screen, it means “low battery
warning”. Itis recommended to replacethebatteries when this warning appears.
Warning: When the product is not used for a long period (more than 15 days), remove
the batteries. Otherwise, malfunctions that may occur would be out of warranty.
Pleasethrowyourdead batteries into thewastebin forbatteries.
7
8
9
1
2
The LEDon thereceiverwillstart toblink green.
Setup will begin with Bluetooth in the application. When the device is found, press
the“Add” button.
WHAT ARE THE ADVANTAGES OF HT330S SMART?
10
11
12
You can control your home's temperature via its mobile application, no matter
whereyouarein theworld.
Uygulamada bluetooth ile kurulum başlayacaktır. Cihaz bulununca “Add”
butonuna basınız.
3
4
5
6
RECEIVER PLACEMENT
You can easilycreatedaily and weeklyschedules viaitsmobile application.
You can place the room thermostat anywhere in your home, thanks to its use with
batteries.
The important things to note for the Receiver placement are
avoiding physical contact between the receiver and the
heating/cooling unit, and protectingitagainst materialssuch
asliquid, dust, etc.
Press the “+” button near the W Modem device and press the “Next” button after
making surethatyouenteredthecorrectWi-Fiinformation.
Wait until the setup process is completed. When you saw the green approval
symbol on theW Modem, pressthe“Done” button in thetop-right corner.
1
2
3
4
5
6
7
8
9
Hour Indicator
It ensures that your living space stays at the desired temperature at any time. In
this way, you can saveup to 30% on your bills by preventingyour heating unit from
working unnecessarily.
Room Temperature
Economy Mode
Comfort Mode
ROOM THERMOSTATTEMPERATURE CALIBRATION
Holiday Mode
The devices should be placed to minimize the damage to the received and
transmittedsignals bypayingattentiontothefollowingpoints;
RULES THAT NEED TO BE OBSERVED FOR SAFETY
Temperaturesensors which areused in room thermostatsarehighly sensitive.
You may need to calibrate your room thermostat if you would like to get the same
temperaturevaluesasother thermometersin yourliving space.
Weekly Program Mode
Day Indicator
Screen Lock
Battery Indicator
Set Temperature
Heating Indicator
- If the Heating Indicator is blinking, the heating unit is working.
- If the Heating Indicator is steady, the heating unit is not working.
Cooling Indicator
- If the Cooling Indicator is blinking, the cooling unit is working.
- If the Cooling Indicator is steady, the cooling unit is not working.
1- Be sureto readtheuser manual beforeusing thedeviceand itsequipment.
2- Opening, disassembly, or use of plastic parts of the product and equipment other
than theintended purpose areout of warranty.
The devicesshould not be mounted on metalsurfaces.
The devices should not be installed close to electrical cables and electronic
equipment such ascomputers and televisionunits.
While yourdeviceis turned off, pressthe“ON/OFF”button for 3 seconds.
Press the "ON/OFF" button until the “ ” menu appears. To see the desired
3- Please make sure that the sockets to which you connect your devices and
equipment areattherecommendedvoltagevaluein theuser manual.
4- Keep away and protect your product and its equipment from all kinds of external
substances such asliquid, dust, heat, etc.
The devices should not be installed near large metal structures or other building
materialsusing finemetalmeshes such asspecialglass or specialconcrete.
Distance between the room thermostat and the Receiver should not exceed 20
metersor 2 floors.
10
11
temperature, set the temperature difference by pressing the “Temperature
AdjustmentButtons”. This valuecan be arranged between“-8° C" and “+8°C".
To save the settings and exit, press the " ON/OFF " button until the device turns
off.
5- Do not expose the device cables to any jamming and pressure. Take care to
connect thedevices'energyconnection to thesocketsyoucan alwaysreach.
6- Turn off the electrical power to prevent damage to your device and apparatus in
caseof lightning and thunderstorms.
Note: Recommended temperaturecalibration is“0.0oC”.
The receivermust be installed atleast50cmawayfromtheheating/cooling unit.
Note: During active use of the room thermostat, the symbols indicated by 3, 4, 5, 6,
RECEIVER INSTALLATION
ROOM THERMOSTAT HYSTERESIS POSITIVE MENU
10, 11 and 12 willnot appear on thescreen.
First, shut down your heating/cooling unit and your heating/cooling unit's power
sourcewithallelectricalcurrent(fuse, socket, etc.)
The hysteresis positive factory setting of your room thermostat is 0.5°C. This value
may be adjusted between “0.1°C” and “2.0°C”. While the hysteresis positive value is
0.5°C, if the room temperature goes above 0.5°C of the set temperature, your room
thermostat will send a signal to your heating/cooling unit. For instance, when you
set your room thermostat to 22.0°C, if the room temperature goes above 22.5°C, on
the heating mode your heating unit will stop working; on the cooling mode your
cooling unit willstart working. To change thehysteresispositivesetting:
7- Turn off theelectricalpower when yourdeviceis not used for along time.
8- Your devices and equipment should be used by paying attention to the matters
stated in the user manual. In case of damage and malfunctions, arising from
improper use (contact with liquid, falling to the ground, etc.) definitely ask for the
installer's help.
RECEIVER
As shown in the connection diagram, connect one end of the heating/cooling unit
connection cableto theCOMand theother to theNO input of thereceiver.
Connect the other ends of the cable -which you connected to the receiver- to the
room thermostat connection terminal as shown in your heating/cooling unit's
user manual.
1-Manual Operation Button:
Deactivates the receiver and allows users to
1
manually use the heating/cooling unit.
2-Wi-Fi Pairing Button:
2
9- Call our service for maintenance and repairof HT330S SMART and its equipment.
Maintenance and repair of the device and equipment should be carried out only by
the technical service of ISIPARK A.Ş. and its authorized services, spare parts, and
accessoriesspecifiedbythecompany should be used.
3
Makes the receiver ready for smart installation.
3-Receiver LED Light
4-Receiver Power Cable Input
You must first connect the receiver power cable to the receiver and then to the
fuse to which theheating/cooling unit is connected.
While yourdeviceis turned off, pressand hold the“ON/OFF”button for 3 seconds.
Pressthe“ON/OFF”button until the“ ” menu appears.
5-Heating/Cooling Unit Connection Cable Input
Adjust the operating sensitivitybyusing the “Up” and “Down”buttons in the “
hysteresispositivemenu.
”
After completing the cable connection process, first, turn on your fuse and then
yourheating/cooling unit.
HT330S SMARTand EQUIPMENT
HT330S SMART
Room Thermostat
To savethesettingsand exit, pressthe"ON/OFF"button until thedeviceturns off.
Changes have been saved. Your room thermostat will be working with set
operating sensitivitywhen youopen yourdevice.
Finish the installation of the room thermostat to pair the receiver with the room
thermostat.
Holder Alkaline
Battery
Receiver
Dowels and
Screws
AC
(230V)
RECEIVER WIRING DIAGRAM
COM
NO
4
5
ROOM THERMOSTAT HYSTERESIS NEGATIVE MENU
RECEIVER LED DESCRIPTIONS
The hysteresis negative factory setting of your room thermostat is -0.5°C. This
value may be adjusted between “-0.1°C” and “-2.0°C”. While the hysteresis negative
value is -0.5°C, if the room temperature goes below 0.5°C of the set temperature,
your room thermostat will send a signal to your heating/cooling unit. For instance,
when you set your room thermostat to 22°C, if the room temperature goes below
21.5°C, on the heating mode your heating unit will start working; on the cooling
mode your cooling unit will stop working. To change the hysteresis negative
setting:
Blinking Red
The receiver did not get any signal from the heating/
cooling unit for 22 minutes or longer and the heating/
cooling unit has shut down.
TECHNICAL DATA
Room Thermostat
Fast Blinking Red
Steady Red
Waiting for a pairing signal from the room thermostat.
The receiver and the room thermostat have been paired.
Smart installation has not been completed.
The receiver is in Bluetooth searching mode.
Smart installation has been completed.
The heating/cooling unit is not working.
The heating/cooling unit is working.
Dimensions (H/L/W)
Operating Current
Temperature Measurement Accuracy
Operating Sensitivity
Operating Temperature Range
Battery Life
85mm / 125mm / 20mm
3V DC (2 x AAA Alkaline Battery)
Blinking Green
Steady Green
0.1oC
(-2.0oC) – (+2.0oC)
(5oC) – (40oC)
1 Year (2 x AAA)
(-10oC) – (+50oC)
(-20oC) – (+60oC)
While yourdeviceis turned off, pressand hold the“ON/OFF”button for 3 seconds.
Pressthe“ON/OFF”button until the“ ” menu appears.
HEATING/COOLING UNIT
Steady Turquoise
3 Short Red Blinking
Shut the heating/cooling unit down signal has reached
the receiver.
Warning! Operations within the heating/cooling unit or the electrical installation
Adjust the operating sensitivitybyusing the “Up” and “Down”buttons in the “
hysteresisnegativemenu.
”
Operating Temperature
Storage Temperature
must be carriedout byprofessionally qualified persons.
3 Short Green Blinking
Operate the heating/cooling unit signal has reached the
receiver.
To savethesettingsand exit, pressthe"ON/OFF"button until thedeviceturns off.
Changes have been saved. Your room thermostat will be working with set
operating sensitivitywhen youopen yourdevice.
Receiver
PAIRING THE ROOM THERMOSTAT WITH THE RECEIVER
Blinking Red and Green The heating/cooling unit is working in manual mode.
Dimensions (H/L/W)
Operating Current
Relay NO Switching Current
90mm / 90mm / 25mm
230V AC
7A (240VAC – Resistive Load)
10A (120VAC – Resistive Load)
(-20oC) – (+60oC)
To pair the room thermostat with the receiver, press the “Manual Operation
Button” and “Wi-Fi Pairing Button” together at the same time and see the
receiver's fastblinking redLED.
ROOM THERMOSTAT PLACEMENT
The room thermostat needs to be placed in the room which is used most frequently.
For instance; the living room or lounge. Placing the room thermostat in a spot that
has air circulation like the entrance of a room or the side of the window should be
avoided. Also anywhereclose to heating/cooling units such as a radiator, stove, and
spots that get directsun lights would not be suitable. The roomthermostat needs to
be located abovethe floor 150 cm in height. Few trials may be made to find the most
convenientspot.
Pressthe“ON/OFF”button for 3 seconds while yourdeviceisturned off.
Pressthe“ON/OFF”button until “
Storage Temperature
” thepairing menu appears.
Press your room thermostat's “Up” or “Down“ button while the LED is fast blinking
red.
Ifthepairing is successful, thefastredflashing LEDon thereceiverwillbe steady.
The receiverand room thermostathavebeen pairedwitheachother.
1
2
3
4
| General | Details |
|---|---|
| Name | GENERAL HT330S Smart Room Thermostat User Manual |
| Make | GENERAL |
| Language | English |
| Filetype | PDF (Download) |
| File size | 2.14 MB |

GENERAL ARUNA 300S Smart Room Thermostat User Manual

GENERAL HT250S Digital Room Thermostat User Manual

GENERAL FH260S Underfloor Heating Thermostat User Manual

GENERAL HT100S Digital Room Thermostat User Manual

GENERAL SOLARA 330S SMART Smart Room Thermostat User Manual

GENERAL HT250 Digital Room Thermostat User Manual

GENERAL SENNA 300 Digital Room Thermostat User Manual

GENERAL ARUNA 300S RF Digital Room Thermostat User Manual

GENERAL SENNA 300 Smart Room Thermostat User Manual

GENERAL MITRA 250S Digital Room Thermostat User Manual

GENERAL HT330S Smart Room Thermostat User Manual Overview
Summary of Contents
- Page 1: Room thermostat Smart room thermostat is a device that allows you to control your heating equipment via an app with the internet even when you are not at home. For smart receiver setup, download the Smart Life application from the App Store or Google Play. Complete the user registration process by opening the mobile application that you downloaded. HT330S Smart is a smart wireless room thermostat that can be controlled with a mobile application after pairing with the receiver. You can easily create daily and weekly schedules via its mobile application. The important things to note for the receiver placement are avoiding physical contact with the heating/cooling unit and protecting it against materials such as liquid and dust. You may need to calibrate your room thermostat to get the same temperature values as other thermometers in your living space. The hysteresis positive factory setting of your room thermostat is 0.5°C and can be adjusted between 0.1°C and 2.0°C. The room thermostat needs to be placed in the room that is used most frequently, avoiding spots with direct sunlight or close to heating/cooling units. To pair the room thermostat with the receiver, press the Manual Operation Button and Wi-Fi Pairing Button together.
- Page 2: Open window detection feature helps prevent unnecessary energy consumption by turning off the heating/cooling unit when sudden temperature changes are detected. When the product is not used for a long period, it is advised to remove the batteries to avoid malfunctions. The room thermostat sends a status signal to the receiver every 3 minutes to maintain synchronization. If the connection is broken for 22 minutes, the heating/cooling operation will stop for safety reasons. In case of a power failure, the receiver will not operate until it receives an 'operate' signal from the room thermostat. The warranty does not cover damages caused by transportation or faulty electrical installations. The heating unit remains off for 10 minutes after an open window is detected, and a warning appears on the mobile application. The warranty period starts from the invoice date and covers manufacturing defects for 2 years. In case of malfunction during the warranty period, the repair period cannot exceed 20 working days. The room thermostat can be reset to factory settings, which will erase all custom settings and return to default values.