FEATURES
REFRIGERATION SYSTEM (continued)
INDOOR REFRIGERANT DETECTION SYSTEM (RDS)
• Complies with UL 60335-2-40 approved standard
• Required for all systems using R-454B refrigerant
• Factory or field installed on all indoor units
• Consists of a RDS refrigerant detection sensor and a
mitigation control in the indoor unit
High Pressure Switch
• Protects the system from high pressure conditions that
can be a result of fan failure or a blocked/dirty coil
E
• Automatic reset
Optional Accessories
• Ensures safe operation for systems equipped with
R-454B refrigerant
• Indoor sensor will detect any R-454B refrigerant
• If R-454B refrigerant is detected, the refrigerant
detection system will stop compressor operation and
operate the blower to reduce concentrations in the
conditioned space
• Once safe levels are reached the HVAC system will
resume normal operation
Expansion Valve Kits
• Field installed on indoor units (if required)
• See TXV Usage table
• Chatleff-style fitting
Freezestat
• Senses suction line temperature
• Cycles compressor off when suction line temperature
falls below freezestat setpoint
• Opens at 29°F and closes at 58°F
• Refer to indoor unit Product Specifications documents
for additional details
• Installs on or near the discharge line of the evaporator or
on the suction line
PRECISE COMFORT® TECHNOLOGY
The Variable Capacity Rotary Compressor and DC Inverter
Control is an integrated system that operates together
to reduce overall energy usage when compared to
conventional air conditioners.
Loss of Charge Switch Kit
• Protects compressor from damage from low refrigerant
charge conditions
• SPST, normally-closed
• Automatic reset
Variable Capacity Rotary Compressor
• High volumetric efficiency
F
Refrigerant Line Kits
• Uniform suction flow
• Constant discharge flow
• High efficiency
• Quiet operation
• Low gas pulses during compression reduces operational
sound levels
• Refrigerant lines are shipped refrigeration clean
• Lines are cleaned, dried, pressurized and sealed at
factory
• Suction line fully insulated
• Lines are stubbed at both ends
NOTE - EL18KCV is a variable capacity air conditioner
utilizing variable speed compressor technology.
With the variable speed compressor and variable
pumping capacity, additional consideration
must be given to refrigerant piping sizing and
application.
• Compressor motor is internally protected from excessive
current and temperature
• Compressor is installed in the unit on resilient rubber
mounts for vibration free operation
Rotary Compressor Operation
• Rotary compressor has a cylindrical chamber
• A roller is mounted to the motor shaft and is offset to
rotate in the center of the chamber
Refer to the Installation Instructions for Line Set
Requirements and Refrigerant Piping Guidelines
• Two spring-loaded vanes sweep the sides of the
chamber as the roller rotates
• Roller touches the chamber at a point between the
intake and the discharge ports as the roller rotates
• While rotating, the roller draws vapor into the chamber
through the intake port
• Vapor is trapped in the space between the chamber wall,
the vane, and the point of contact between the roller and
the chamber
• As the next vane passes the contact point vapor is
compressed
• The space becomes smaller compressing the vapor as
the roller rotates
• Vapor is discharged through the discharge port
EL18KCV | 2 to 5 Ton Air Conditioner | Page 4