Home > bandary > bandary FC660 Smart Thermostat User Guide

bandary FC660 Smart Thermostat User Guide

CE power and frequency band information are as follows:  
Transmitter Frequency:2.4G Wi-Fi: 2412-2472MHz  
Receiver Frequency:2.4G Wi-Fi: 2412-2472MHz  
Step 5: Separate the base from thermostat by disassembly tool, pulling  
the control wires through the large opening in the thermostat base.  
Smart thermostat FC660  
Data sheet  
Subject to technical alteration  
Compatibility  
Compatibility  
Installation Description  
The Smart Thermostat works with most 24V systems, including gas  
fuel, electric fuel, oil fuel, heat pump and radiant.  
It can control:  
As a component of a large-scale fixed installation, Manufacturer products  
are intended to be used permanently as part of a building or a structure  
at a pre-defined and dedicated location, hence the Waste Electrical and  
ElectronicAct (WEEE) is not applicable. However, most of the products  
may contain valuable materials that should be recycled and not disposed  
of as domestic waste. Please note the relevant regulations for local  
disposal.  
Step 1: Power off your Heating,  
Ventilation, andAir Conditioning  
(HVAC) system by using the master  
switch or circuit breaker box.  
RF-Output Power:2.4G Wi-Fi: 17.95dBm  
Next, level and mount the base on the wall using the supplied screws.  
Do not over tighten the mounting screws as the thermostat base may  
warp causing an improper seating of the thermostat connecting pins to  
the terminal blocks. Use a properly sized installation tool to indicate the  
connection terminal according to the arrow of the base before connecting  
each wire to its dedicated terminal.  
Issue date: 17.12.2024  
Mounting advice  
• Heating:one and two stages (W1, W2)  
• Cooling:one and two stages (Y1, Y2)  
• Heat pump: with auxiliary(O/B,AUX)  
• Fan (G)  
Dear customer,  
This is important for your safety.  
Thank you very much for your purchase, so glad to have nice chance to  
serve you. In order to have a good experience, please keep this user  
manual properly, after buying our product .  
Tip: Look for your master switch or circuit breaker box in the basement,  
attic, utility closet, or behind a wall panel near the thermostat.  
• Power (C, RH, RC)  
Technical Data  
Ensure all power is disconnected before installing. Do not connect to  
live operating equipment.  
STEP 2: Confirm your system  
Security Advice – Caution  
C
is off by turning on your heat (during  
winter) or your AC (during summer).  
Wait a few minutes —you should  
not feel air coming from your vents.  
G
Y1  
RH  
Power supply  
AC 24V 50/60Hz  
WIFI 2.4G communication  
0~+50  
* Please install the product at normal temperature with good ventilation,  
keep away from heat source, windows and doors, avoid direct sunlight.  
The installation and assembly of electrical equipment should only be  
performed by authorized personnel.  
Network technology  
Measuring range temp.  
The product should only be used for the intended application.  
Unauthorized modifications are prohibited! The product must not be  
used in relation with any equipment that in case of a failure may  
threaten, directly or indirectly, human health or life or result in danger  
to human beings, animals or assets. Ensure all power is disconnected  
before installing. Do not connect to live/operating equipment.  
Product list  
Set point adjustment 0~50℃  
(default +16~+30)  
Tip: If you have a boiler, check to see that the main flame is extinguished.  
Control functions  
Display  
Disassembly  
thermostat  
Mount the supplied  
screws  
Connection terminals  
Step 3: Remove your old  
TFT Resolution 480*480  
Colorful display  
thermostat cover from the wall.  
User Manual  
2
Aluminum alloy, tempered glass, fire  
proof PC &ABS  
1
Enclosure  
Tip: Many thermostats simply pop off or unclip from the base, while  
others may have screws that you will need to remove.  
C
Base 1pc  
G
Display 1pc  
Data sheet 1pc  
Y1  
RH  
Application  
IP20 according to EN60529  
Rear entry  
Protection  
CAUTION! Risk of electric shock due to live components within  
the enclosure, especially devices with mains voltage supply .  
4
Step 4: Take a picture of the wires  
connected to the terminals of your  
old thermostat. You may need to  
reference this photo later.  
3
Cable entry  
Ambient condition  
Mounting  
FC660 smart thermostat is a device for indoor temperature control.  
It is mainly applied to conventional system or heat pump system for  
heating/cooling, with 3 modes easily switchable: Holiday, Away and  
Home. The device is of high reliability and practicability, and it can  
support up to 3H/2C system.  
-10~+50, max. 95%rH non-condensing  
Surface mounted  
Please comply with  
• Local laws, health & safety regulations, technical standards and regulations  
• Condition of the device at the time of installation, to ensure safe installation  
• This data sheet and installation manual  
Fasten the base and display unit  
Dispaly size  
86*86*33.8mm  
Cover 1pc  
Power  
cable 1pc  
Disassembly  
tool 1pc  
Screws 2pcs  
WARNING: this thermostat is designed for 24VAC with a 0.5Amaximum  
Base size  
86*86*4.5mm  
current. Do not connect it to line (high) voltage or millivolt systems.  
-1-  
-2-  
-3-  
-4-  
-5-  
-6-  
Dual power supply  
conventional system  
Dual power supply conventional  
system withAux device  
Conventional system  
Conventional system  
withAux device  
When the user selects ventilation mode, only the fan start signal is  
output, the cooling and the heating outputs are keep off.  
Terminals Explanation  
Connection wires: Use the disassembly tool to push the terminal down  
according to the arrow on the base and insert the wire into the terminal  
at the same time. If need remove the wire from terminal, use the  
installation tool to push the terminal down in the arrow direction and pull  
out the wire.  
Terminal Connection wiring diagram  
4 Cooling & Heating output  
Power for heating, AC24V  
Power for cooling, AC24V  
RH  
RC  
C
Heat  
output1  
Cool  
output2  
Heat  
output  
Cool  
output2  
Heat  
output1  
Heat  
output1  
24VAC  
Cool  
output2  
Cool  
output2  
24VAC  
Circle color showed blue-the thermostat is running cooling output  
Circle color showed red-the thermostat is running heating output  
Circle color showed white-the thermostat without any output  
Wiring diagram Conventional system  
Aux Heat  
dehumidifier  
humidification  
Heat  
output2  
Cool  
output1  
Fan  
output  
Cool  
output1  
Fan  
output  
Aux Heat  
dehumidifier  
humidification  
Fan  
output  
Cool  
output1  
Fan  
output  
Cool  
output1  
Heat  
output2  
24VAC  
24VAC  
24VAC  
24VAC  
Common wire, AC24V  
5 TVOC display – Room air quality  
6 CO2 display – Room air quality  
W2  
W1  
G
Y2  
Y1  
C
RC RH  
First outdoor stage cooling on conventionalsystems  
or first heat and cool on heat pump systems  
Y1  
7 Humidity display – Relative room humidity  
Second outdoor stage cooling on conventional systems  
or second heat and cool on two stage heat pump systems  
8 Profile mode – Support holiday/home/away mode adjustment  
(Holiday mode will only display when the user set this holiday  
mode in Parameter Setting)  
Y2  
G
Heat  
output 2  
Fan  
output  
Cool  
output  
Cooling only system  
Cooling only system  
withAux device  
Display panel  
Indoor blower (fan)  
9 Lock - Local thermostat will not be workable when this symbol  
indicated unless it is released by APP on smart phone or input the  
thermostat password (Factory default password "987", and the user  
can set the password, if the user forgot the revised password, the  
user can input the super password "999" to restore the factory  
default passward "987").  
Heat  
output  
Cool  
output 2  
24VAC  
common  
First indoor stage heat on conventional systems or  
first stage auxiliary on heat pump systems  
W1  
Cool  
output2  
Main interface:  
Cool  
output2  
AC24V  
Aux Heat  
dehumidifier  
humidification  
Fan  
output  
Cool  
output1  
Fan  
output  
Cool  
output1  
Second indoor stage heat on conventional systems or  
second stage auxiliary heat on heat pump systems  
24VAC  
24VAC  
W2  
3 Cooling/Heating/  
Ventilation mode  
Changeover (reversing valve) connection for heat  
pump or zone panel systems  
10 Temperature display – The thermostat displays room temperature.  
(Factory default: display), the user can switch to Fahrenheit (°F)  
by APP  
O/B  
Wiring diagram Heat Pump system  
AUX  
Auxiliary output  
AUX O/B G  
Y2  
Y1  
C
RC RH  
11 ECO mode – In ECO mode it will show the leaf and the word  
ECO in the display  
Wiring Instructions  
Heating only system  
Heating only system  
withAux device  
In ECO mode, factory default cooling temperature is 28, heating  
temperature is 19.(The user can revised the ECO temperature in  
Parameter Setting)  
1 Setpoint – Factory default is 16~30(60~86)  
Heat pump system  
Heat pump system  
withAux device  
2 Wifi symbol – 3 different status display  
Blink in gap indicates the thermostat is offline  
Rapid blink indicates the device is in pairing  
Heat  
output1  
Heat  
output1  
O/B  
output  
Cool  
output2  
O/B  
output  
Cool  
output2  
Aux Heat  
dehumidifier  
humidification  
Cool.  
output  
Fan  
output  
Auxiliary  
Heat output  
Heat  
output2  
Fan  
output  
Fan  
output  
24VAC  
24VAC  
Aux Heat  
dehumidifier  
humidification  
Normal status indicates the thermostat connects to router or server successfully  
Cool  
output1  
Fan  
output  
Cool  
output1  
Fan  
output  
Communication  
24VAC  
24VAC  
Cool.  
output 2  
Changeover  
Vavle  
24VAC  
common  
3 Cooling, Heating & Ventilation mode – When the user selects cooling  
mode, the thermostat detects the room temperature is higher than the  
set temperature, the cooling start signal will be output.  
When the user selects heating mode, the thermostat detects the room  
temperature is lower than the set temperature, the heating start signal  
will be output.  
Wifi communication:  
DownloadAPP:  
1.1Search for “Smart Life” or “Tuya Smart” in IOS/AndroidApp and  
download, or scan the relevant QR code here.  
AC24V  
-7-  
-8-  
-9-  
-10-  
-11-  
-12-  
GeneralDetails
Namebandary FC660 Smart Thermostat User Guide
Makebandary
LanguageEnglish
FiletypePDF (Download)
File size2.24 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
FC610 Bandary Smart Thermostat Owner’s Manual
FC610 Bandary Smart Thermostat Owner’s Manual

bandary FC660 Smart Thermostat User Guide
Get the free PDF manual for the bandary FC660 Smart Thermostat User Guide and access setup steps, usage instructions, and troubleshooting tips. 👉 View online or download now to keep your thermostat running smoothly!

bandary FC660 Smart Thermostat User Guide Overview

Summary of Contents

  • Page 1: Transmitter Frequency: 2.4G Wi-Fi: 2412-2472MHz Receiver Frequency: 2.4G Wi-Fi: 2412-2472MHz The Smart Thermostat works with most 24V systems, including gas fuel, electric fuel, oil fuel, heat pump, and radiant. Ensure all power is disconnected before installing. Do not connect to live operating equipment. This thermostat is designed for 24VAC with a maximum current of 0.5A. The installation and assembly of electrical equipment should only be performed by authorized personnel. The product should only be used for the intended application. The device is of high reliability and practicability, and it can support up to 3H/2C system. In ECO mode, factory default cooling temperature is 28℃, heating temperature is 19℃. When the user selects cooling mode, the thermostat detects the room temperature is higher than the set temperature, the cooling start signal will be output. Look for your master switch or circuit breaker box in the basement, attic, utility closet, or behind a wall panel near the thermostat.
  • Page 2: Select “Check the R wire”, rotation the first ring to select the “Rc or Rh” or “Rc and Rh”, press the touch panel to confirm the selection. Select “Auxiliary setting”, rotation the first ring to select the “None” or “First stage heat for heat pump” or “Humidification” or “Dehumidifier”. Select “Temperature difference setting” by rotation the second ring from 1℃ (2℉) to 5℃ (9℉), factory default 1℃. Select “Equipment Installation Setting”, rotation the first ring to select the “Heat Pump” or “Multi Heat Pump” or “Heat Only” or “Cool Only”. Select “Equipment startup delay”, rotation the second ring to select the delay time from 0~15min, factory default 3min. In parameter set two interface, choose the “WiFi pair” to enter pair mode, the “WiFi” symbol flash in main interface. Final confirm “Equipment type”, display the parameters previously selected by the user, if correct, select “Next” and press the touch panel to proceed to the next step. Set “Holiday start time”, “Holiday stop time” & “Holiday setting temp.”, time setting sequence is month, day, year, hour, minute, and am/pm. Input password “987” to enter System Configuration. Press the panel to select “Power On” or “Power Off”.