Home > bandary > bandary FC660 Smart Thermostat User Guide

bandary FC660 Smart Thermostat User Guide

1-Select “Check the R wire”, rotation the first  
ring to select the “Rc or Rh” or “Rc and Rh”,  
press the touch panel to confirm the  
selection. (Tip: The System Configuration  
confirmation method for each selection is  
the same)  
Main interface  
Cooling&Heating  
&Ventilation  
mode adjustment  
5-Select “Auxiliary setting”, rotation the first  
ring to select the “None” or “First stage  
heat for heat pump” or “Humidification”  
or “Dehumidifier”.  
Profile Mode Selective  
9-Select “Temperature difference  
setting” by rotation the second ring  
from 1(2) to 5(9), factory  
Profile modes setting (Tip: In parameter setting interface,  
enter main interface method is the same→Short press the  
panel then enter main interface.)  
Rotate the second ring in clockwise  
to adjust the profile mode:  
Profile mode  
adjustment  
away→home→away...to recycle.  
IOS & Android  
1.2 Register account inAPP.  
default 1.  
Rotation the first ring to select 3 modes  
(Away mode/Daily mode/Holiday mode)  
Daily mode  
Mode selective  
and press the panel to confirm the  
2.1 In parameter set two interface, choose the “Wifi pair” to enter  
pair mode, the “Wifi” symbol flash in main interface, the device is  
in pairing status.  
10-Final confirm “Equipment type”, display the parameters previously  
selected by the user, if correct, select “Next” and press the touch  
panel to proceed to the next step; Finally, select “Finish” to enter  
Main Interface.  
Rotate the second ring in anticlockwise to adjust the mode:  
cooling→heating→ventilation→cooling...to recycle  
2-Select “Equipment Installation Setting”,  
selection.  
rotation the first ring to select the “Heat  
Pump” or “Multi Heat Pump” or “Heat  
Only” or “Cool Only” or “Back(Back to the  
Previous Level)”.  
6-Select “Equipment startup delay”, rotation  
Note: In mode switch, each operation will have an prompt on panel,  
rotate the first ring to select whether switch, press the panel to  
confirm the selection.  
the second ring to select the delay time  
from 0~15min, factory default 3min.  
2.2 Click on “+” symbol to “Add device” on “Smart Life” or “Tuya  
Smart”, turn on phone WIFI, and then find “Small Home Appliance”  
menu to click on “Thermostat (Wi-Fi)”, then please follow the step  
to input wifi account no. and password.  
1 “Away mode” setting:  
You need to rotate the second ring by a larger amplitude (more than  
1/4 turn) to shift the modes  
Set the “Heat” & “Cool” temperature,  
and “Fan” mode to On/Off.  
2.3 Follow up with the guideline to operate the next step, the APP  
will automatic search the device, and add in its register here.  
Parameter Setting  
Enter into Parameter Setting  
3-Select “How is your O/B Reversing  
7-Select temperature display format  
2.4 Connect successfully, then the user can control the smart  
thermostat by APP.  
Valve energized”, rotation the first ring  
to select the “On cool” or “On Heat”.  
2 “Daily mode” setting:  
In main interface long  
” or “” by anticlockwise the  
1 Main interface  
Set “Temp. time set” from Monday to Sunday(Figure 1), each day  
can be set 6 periods(Figure 2) according to the user’s requirement  
(Figure 3);  
2 Profile modes  
setting  
5 ECO On/Off  
set  
press the panel for more  
than 2-second, then the  
user get the parameter  
setting interface:  
second ring.  
3 Parameter  
set one  
6 Key Lock/  
Unlock set  
Main interface function operation:  
7 Fan On/Off  
set  
4 Power On/Off  
set  
Function operation instruction  
8 Parameter  
set two  
Set temperature setting  
System configuration:  
The thermostat is powered on for the first time, follow the display  
4-Select “Second level cool and heat  
In main interface, clockwise rotation the first ring,  
the setting temperature would be 0.5℃ꢀincrease;  
Otherwise, anticlockwise rotation the first ring  
will keep temperature 0.5℃ꢀdecrease.  
8-Select “Dead band setting” by rotation  
Rotation the first ring to select the parameter setting, and press the  
panel to confirm the selection.  
setting”, rotation the first ring to select  
the “Yes” or “No”.  
the second ring from 0.5(1) to 5℃  
guideline to select and confirm the system configuration;  
(9), factory default 0.5(1).  
(Tip: The Parameter Setting method is the same)  
Figure 1  
Figure 2  
-18-  
Figure 3  
-14-  
-15-  
-13-  
-17-  
-16-  
3 “Holiday mode” setting  
7 Modbus:Setting the Modbus-RTU parameters.  
3 IO state: Display the thermostat input and output state.  
Dimension  
Set “Holiday start time”(Figure 4), “Holiday stop time”(Figure 5) &  
“Holiday setting temp.”(Figure 6), time setting sequence is month,  
day, year, hour, minute, and am/pm. In “Holiday setting” interface,  
select heat/cool “On” or “Off ” and temperature setting from 16~30,  
fan runtime(min/hr) from 0~60 (Tip: We recommend 0 min/hr.)  
4 System set: Input password “987” to enter System Configuration.  
Fan On/Off Set  
Press the panel to select “Fan On” or “Fan Off”.  
5 System information:Display the thermostat software & hardware  
version.  
Key Lock/Unlock Set  
Press the panel to select “Lock” or “Unlock”.  
6 Password modification: Input old password “987” to reset the  
password according to user’s requirement.If the user forgot the  
modified password, the user can input the super password "999" to  
restore the factory default passward "987".  
ECO On/Off Set  
Press the panel to select ECO mode “On” or “Off”.  
7 Restore factory settings: Input password “987” to restore to factory  
default value.  
Power On/Off set  
Press the touch panel to select “Power On” or “Power Off”.  
5
5...50>0.5-5  
Parameter set two  
Figure 4  
Figure 5  
Figure 6  
1 ECO mode: Set the ECO cool temperature  
and ECO heat temperature  
Parameter set one  
RH%  
10...50>1-5  
ECO mode  
wifi pairing  
backlight delay  
Rotation the first ring to select the parameter  
and press the panel to confirm the selection.  
Select “Back” to return to the previous  
interface.  
FCC Caution  
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not  
cause harmful interference, and (2) this device must accept any interference received, including interference that may cause  
undesired operation.  
2 Wifi pairing: Select the reset the wifi pair,  
timer  
fault list  
Service support  
Modbus  
the thermostat is in pairing status.  
Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to  
operate the equipment.  
3 Backlight delay: The thermostat backlight  
setting from 0~100% brightness  
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.  
These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment  
generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause  
harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular  
installation. lf this equipment does cause harmful interference to radio or television reception, which can be determined by turning  
the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:  
(Tip: The Parameter Selection & Confirmation  
method is the same)  
4 Time: Time setting sequence is month, day, year, format, hour,am/pm,  
minute.  
1 Temp./hum. offset: Set temperature offset from 0~10, the  
temperature offset would be 0.5increase or decrease; Set  
humidity offset from 0~100%, the humidity offset would be 1%  
increase or decrease.  
-Reorient or relocate the receiving antenna.  
-Increase the separation between the equipment and receiver.  
-Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.  
-Consult the dealer or an experienced radio/TV technician for help.  
5 Fault list:Setting the fault parameters.  
RH  
6 Service supports: If you have any questions, please scan the panel  
QR code to contact the technician.  
FCC Radiation Exposure Statement  
2 Temp. up/down limit: Set the upper setting temperature limit from  
16.5~50; Set the lower setting temperature limit from 1~30.  
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment .  
This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.  
This equipment should be installed and operated with minimum distance 20cm between the radiator& your body.  
-19-  
-21-  
-22-  
-23-  
-24-  
-20-  
GeneralDetails
Namebandary FC660 Smart Thermostat User Guide
Makebandary
LanguageEnglish
FiletypePDF (Download)
File size2.24 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
FC610 Bandary Smart Thermostat Owner’s Manual
FC610 Bandary Smart Thermostat Owner’s Manual

bandary FC660 Smart Thermostat User Guide