Remotec REMEZTRVV01 Z Wave Thermostat User Guide
Remotec
Remotec Thermostat Z-Wave
SKU: REMEZTRVV01
Quickstart
This is a secure Z-Wave Device for Europe. To run this device please insert fresh 2 * AA batteries. Please make sure the internal battery is fully charged.
1. Add TRV DSK into the primary controller SmartStart Provisioning List (If you don’t know how to do this, refer to its manual, DSK usually print on the main
body).
2. Remove the battery from the TRV. A few seconds later, repowered in the TRV.
3. The TRV will send “Z-Wave protocol Command Class” frame to start SmartStart Inclusion.
Important safety information
Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer,
distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this
equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
What is Z-Wave?
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and
every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is
not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified
Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this
device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level
of security to maintain backward compatibility.
Product Description
The TRV based on Z-WaveTM Slave library of V7.16.03. This TRV integrated Z-Wave communication module to connect with Z-Wave gateway.
The TRV can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applications.
The TRV is a security Z-Wave device (S0/S2), so a security enabled controller is needed for take full advantage of all functionally for the TRV.
Prepare for Installation / Reset
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do
this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended
to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
Reset to factory default
This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.
In “OF” state, press and hold rotary plate for at least 5 seconds and release when the screen will blink “OF”. When the reset is successful, the screen will show
“OF” in solid for 2 seconds then turn off. And TRV will reset itself to factory default by sending a “Device Reset Locally Notification” to gateway.
Safety Warning for Batteries
The product contains batteries. Please remove the batteries when the device is not used. Do not mix batteries of different charging level or different brands.
Installation
IMPORTANT: Please include your TRV to the network (refer to 4.1) before doing the installation. Below is the installation process:
| General | Details |
|---|---|
| Name | Remotec REMEZTRVV01 Z Wave Thermostat User Guide |
| Make | Remotec |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.27 MB |

Remotec REMEZTRVV01 Z Wave Thermostat User Guide Overview
Summary of Contents
- Page 1: Remotec thermostat Z-Wave is a secure Z-Wave device for Europe. To run this device, insert fresh 2 AA batteries and ensure the internal battery is fully charged. Add TRV DSK into the primary controller SmartStart Provisioning List. Remove the battery from the TRV, wait a few seconds, then repower the TRV. Z-Wave is the international wireless protocol for communication in the Smart Home. This device can be used with any other certified Z-Wave device regardless of brand. The TRV is a security Z-Wave device, requiring a security-enabled controller for full functionality. To include a Z-Wave device, it must be in factory default state. Reset the device to factory default by performing an Exclusion operation. Remove batteries when the device is not in use and do not mix different brands or charging levels.
- Page 2: Choose the right adapter and install it to the valve if the TRV cannot install to your valve directly. Take off the batteries and put them on again to repower the TRV. The screen will blink “LA” until it becomes solid. Install the TRV to the valve. Click the rotary plate once and the “LA” will start blinking again. Installation completed when “LA” disappears and shows the temperature. On factory default, the device does not belong to any Z-Wave network. Inclusion is the process of adding the device to an existing wireless network. Exclusion is the process of removing devices from a network. Both processes are initiated by the primary controller of the Z-Wave network.
- Page 3: Product usage The temperature <5°C, display OF. The temperature > 30°C, display On. Open window function When using the radiator to heat, the window is opened, when the room temperature drops 6°C in 4 minutes, TRV will close the valve automatically. Anti-scale function If the radiator does not open within two weeks, TRV will open the valve running 30 seconds every two weeks, display will show AS. Child lock function Activate the child lock function by long pressing the rotary plate until the display shows LC. Anti-freezing function The valve will be opened when the temperature is below 5°C, when the temperature rises to 8°C, the valve will be closed. Low power alarm When the battery voltage is extremely low, display the battery icon. Battery change Open and remove the cover, insert the batteries checking the polarities are correctly aligned. Quick troubleshooting Make sure a device is in factory reset state before including. Association One device controls another device.
- Page 4: Z-Wave devices control other Z-Wave devices through a relationship called association. Controlling devices maintain a list of devices that will receive commands, known as association groups. Association groups are related to specific events, such as button presses or sensor triggers. When an event occurs, all devices in the association group receive the same wireless command. Z-Wave products are designed to work out of the box, but configuration can enhance functionality. Controllers may only allow configuring signed values, requiring adjustments for certain ranges. Parameter 1: Open window detect function has a default value of 0. Parameter 2: Anti-freezing function also has a default value of 0. Parameter 3: Measured temperature offset allows settings from -6°C to +6°C. Parameter 6: Valve opening level report threshold can be set from 0 to 100%.
- Page 5: Parameter 8: Temperature change report threshold Size: 1 Byte, Default Value: 5 Parameter 9: Battery auto report interval time The time interval when to send the battery report. Parameter 10: Battery change report threshold Size: 1 Byte, Default Value: 5 Parameter 11: Enable child lock Size: 1 Byte, Default Value: 0 Technical Data Dimensions: 0.0500000x0.1000000x0.0500000 mm Weight: 149 gr Battery Type: 2 * AA
- Page 6: Association Grp Info Device Reset Locally Zwaveplus Info Supervision Configuration Manufacturer Specific Powerlevel Firmware Update Md Battery Association Controller is a Z-Wave device with capabilities to manage the network. Slave is a Z-Wave device without capabilities to manage the network. Primary Controller is the central organizer of the network. Inclusion is the process of adding new Z-Wave devices into a network. Exclusion is the process of removing Z-Wave devices from the network. Association is a control relationship between a controlling device and a controlled device. Wakeup Notification is a special wireless message issued by a Z-Wave device to announce that it is able to communicate. Node Information Frame is a special wireless message issued by a Z-Wave device to announce its capabilities and functions.