Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different  
device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are  
always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will  
receive the same wireless command wireless command, typically a 'Basic Set' Command.  
Association Groups:  
Group Number  
1
Maximum Nodes  
Description  
5
Lifeline  
Configuration Parameters  
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further  
enhanced features.  
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the  
desired value minus 256. For example: To set a parameter to 200it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the  
same logic applies: Values greater than 32768 may needed to be given as negative values too.  
Parameter 1: Open window detect function  
Size: 1 Byte, Default Value: 0  
Setting  
Description  
Disable  
0
1
Enable  
Parameter 2: Anti-freezing function  
Size: 1 Byte, Default Value: 0  
Setting  
Description  
Disable  
0
1
Enable  
Parameter 3: Measured temperature offset  
Size: 1 Byte, Default Value: 0  
Setting  
-6 - 6  
Description  
Offset -6°C - (+6)°C  
Parameter 4: Set away home mode  
Size: 1 Byte, Default Value: 0  
Setting  
Description  
0
1
No  
Yes  
Parameter 5: Anti-scale function  
Size: 1 Byte, Default Value: 0  
Setting  
Description  
Disable  
0
1
Enable  
Parameter 6: Valve opening level report threshold  
Size: 1 Byte, Default Value: 1  
Setting  
0 - 100  
Description  
%
Parameter 7: Temperature auto report interval time  
The time interval when to send the temperature report.  