Danfoss ECtemp 610 Electronic Thermostat Installation Guide
| General | Details |
|---|---|
| Name | Danfoss ECtemp 610 Electronic Thermostat Installation Guide |
| Make | Danfoss |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.58 MB |

Danfoss RET-MD Electronic Intelligent Dial Setting Thermostat Installation Guide
Danfoss VICUQ24M Icon Programmable II Room Thermostat Installation Guide

Danfoss MBC 8000, MBC 8100 Heavy Duty Thermostat Installation Guide

Danfoss UT 72-UT 73 Universal Thermostat Installation Guide

Danfoss ECtemp 530 Electronic Thermostat Installation Guide

Danfoss 014G0251 Eco Radiator Thermostat User Guide

Danfoss 014G0013 Z Wave Radiator Thermostat Installation Guide

Danfoss RET230P Electronic Thermostat Instruction Manual

Danfoss TP7000 Range Electronic 7 Day Programmable Room Thermostat Installation Guide

Danfoss RET1000 Series Electronic Thermostat User Guide

Danfoss ECtemp 610 Electronic Thermostat Installation Guide Overview
Summary of Contents
- Page 1: Installation guide for ECtemp 610 electronic thermostat IP44.
- Page 2: Introduction ECtemp 610 is an IP44 electronic thermostat to be installed directly on the wall. It is provided with a 2-pole switch and a wire sensor to control the desired temperature. The thermostat has a button for adjusting the temperature setting with a scale from -10 °C to +50 °C, and an LED indicator that shows standby periods (green light) and heating periods (red light). Technical specifications Safety instructions Mounting instructions Warranty Disposal instruction
- Page 3: Technical specifications Operation voltage: 220-240 V~, 50 Hz Standby power consumption: Max. 0,93 W Relay: Max 10 A / 2300 W @ 230 V Sensing units: NTC 15 kOhm at 25 °C Temperature range: 10 °C to +50 °C Storage temperature: 20 °C to +65 °C Cable specification max: 1 x 4 mm² or 2 x 2,5 mm² Ball pressure temperature: 75 °C Pollution degree: 2 (domestic use) Protection class: Class II
- Page 4: ECtemp 610 Dimensions: 100 x 69.5 x 45 mm Weight: 165 g The product complies with the EN/IEC Standard for automatic electrical controls for household and similar use. Safety instructions include ensuring the mains supply to the thermostat is turned off before installation. The installation must be done by an authorized and qualified installer according to local regulations. The thermostat must be connected to a power supply via an all-pole disconnection switch. The sensor is to be considered as live voltage, especially if it must be extended. Always connect the thermostat to continuous power supply. Do not expose the thermostat to moisture, water, dust, and excessive heat.
- Page 5: Mounting instructions provide placement guidelines. The thermostat can be placed both indoors and outdoors. Place the thermostat on a wall, pole, steel/wooden plate, or pipe. In wet rooms, place the thermostat according to local regulation on IP classes. Installation guide is included.
- Page 6: Follow the steps below to mount the thermostat. Open the thermostat. Set adjustment button to minimum temperature. Loosen the 2 screws and open the front cover. Installation guide.
- Page 7: Fasten the thermostat. Drive the screws through the holes in the bottom corners of the thermostat. Seal the holes with the enclosed screw stopper to maintain the density. Installation guide.
- Page 8: Connect the thermostat according to the connection diagram. Heating connections include L-main, N-main, L-load, and normally open load. Cooling connections include L-main, N-main, L-load, and normally closed load. The screen of the heating cable must be connected to the earth conductor of the power supply cable. Reinstall the front cover. Ensure that the adjustment button can be adjusted within the full temperature range, from -10 °C to +50 °C. Installation guide.
- Page 9: Install the sensor using the supplied sensor cable. The sensor is an NTC 15 kΩ at 25 °C. Press out the blanket located at the bottom of the thermostat and insert the seal nipple. Connect the sensor to terminals 6 and 7. The sensor cable can be extended up to 50 m with 1.5 mm² installation cable without affecting the accuracy of the thermostat. Do not place the cable parallel to other installation cables as undesirable signals may be induced. The installation must be permanent. If the sensor is to be built in, used for pipe applications, or exposed to pressure, always install it in a conduit. Turn on the power supply. Installation guide.
- Page 10: Page 10
- Page 11: Warranty A 2-year product warranty is valid for thermostats: ECtemp 610. Danfoss offers warranty valid from the date of purchase under specific conditions. During the warranty period, Danfoss will offer a new comparable product or repair if found faulty due to defective design, materials, or workmanship. The decision to repair or replace is solely at the discretion of Danfoss. Danfoss is not liable for consequential or incidental damages. The warranty is valid only if the warranty certificate is completed correctly and proof of purchase is provided. The warranty certificate must be filled in, stamped, and signed by the authorized installer. Danfoss warranty does not cover damage caused by incorrect use or installation by unauthorized electricians. All work will be invoiced if Danfoss inspects or repairs faults due to incorrect conditions. The warranty explicitly excludes all claims exceeding the stated conditions.
- Page 12: Warranty certificate The Danfoss warranty is granted to: Purchase date Serial number of the product Product Art. No. Connected output [W] Installation date & signature Connection date & signature
- Page 13: ECtemp 610 Year Warranty Disposal instruction Installation guide
- Page 14: ECtemp 610 Produced by Danfoss © 03/2023
- Page 15: Product documentation Designed in Denmark for Danfoss A/S Operating temperature range: -10 °C to +50 °C Voltage: 230 V~ Frequency: 50 Hz Current: 16 A (3680 W) Protection rating: IP44