Home > WHITE RODGERS > WHITE-RODGERS 1F95-1277 Universal Thermostat Owner’s Manual

WHITE-RODGERS 1F95-1277 Universal Thermostat Owner’s Manual

90 Series Blue Universal Thermostat  
Wiring Diagrams for 1F95-1277  
Single Stage, Multi-Stage, Heat Pump  
Heat Pump Connections  
If you do not have a heat pump system, refer to figures 2 & 3.  
Refer to equipment manufacturers' instructions for specific system  
wiring information.  
HEAT PUMP TYPE 1 (HP 1). Single stage compressor system; gas  
or electric backup.  
HEAT PUMP TYPE 2 (HP 2). Multi-stage compressor or two com-  
pressor system with gas or electric backup.  
After wiring, see INSTALLER CONFIGURATION section for proper  
thermostat configuration.  
You can configure the thermostat for use with the following heat  
pump systems.  
Figure 1 – Heat Pump Systems  
NOTE: If your system does not  
To Remote Temperature Sensor  
provide an E connection, jumper W2  
to W/E to use the Auxiliary Heat in the  
Emergency Mode.  
Jumper  
Jumper  
B
O
RC  
+
Y2  
Y
G
RH  
C
S
-
W2 W/E  
6
L
* 24 VAC common connection  
optional for system operation.  
System  
(Dual  
Fuel  
disabled)  
Emer-  
gency  
Heat  
Pump 1  
(HP1)  
Required for fault or malfunction indi-  
cation, remote temperature sensor, or  
for continuous backlight operation.  
Blower/  
Circula-  
tor Fan  
Energiz-  
ed on  
DC  
Power  
Closed  
Conn-  
ection  
for  
DC  
Return  
to  
No  
Output  
Fault  
Indicator  
or  
1st  
supply  
voltage  
to re-  
24 VAC  
Com-  
mon  
Remote  
Temp-  
erature  
Sensor  
signal  
Energiz-  
ed in  
Heat/  
Auxil-  
iary &  
Emer-  
gency  
Heat  
Stage  
Heat &  
Cool  
Energiz-  
ed in  
Cool  
heat  
2nd stage  
24 VAC  
(Hot)  
Heat  
24 VAC  
(Hot)  
Cool  
Remote  
Te mp-  
erature  
Sensor  
System  
Malfunc-  
tion  
mote  
(Dual  
Fuel  
enabled)  
Auxiliary  
& Emer-  
gency  
(option-  
al) *  
Emer-  
gency  
Mode  
(Com-  
pressor)  
**  
2nd  
& Off  
Mode  
call for  
Heat or  
Cool  
Te mp-  
erature  
Sensor  
3-wire  
zone  
valve  
Heat  
Pump 2  
(HP2)  
** Dual fuel option de-energizes  
compressor when auxiliary heat is  
energized.  
Stage  
Heat/  
Cool  
(Com-  
pressor)  
Comfort  
Alert II module  
or similar  
1st  
Stage  
Switch  
heat  
2nd stage  
malfunction  
module  
NEUTRAL  
24VAC  
HOT  
120VAC  
CLASS II  
TRANSFORMER  
Single Stage and Multi-Stage Connections  
Refer to equipment manufacturers' instructions for specific system  
wiring information.  
SiNglE STAgE (SS 1) gas, oil or electric.  
MUlTi-STAgE (MS 2) gas, oil or electric.  
After wiring, see INSTALLER CONFIGURATION section for proper  
thermostat configuration.  
This thermostat is designed to operate a single-transformer or two-  
transformer system.  
You can configure the thermostat for use with the following fossil fuel  
systems:  
Figure 2 – Single Stage or Multi-Stage System (No Heat Pump) with Single Transformer  
To Remote Temperature Sensor  
Jumper  
B
O
RC  
+
Y2  
Y
G
RH  
C
S
-
W2 W/E  
6
L
System  
Blower/  
Circula-  
tor Fan  
Energiz-  
ed on  
Ener-  
gized  
* 24 VAC common connection  
optional for system operation.  
Single  
Stage 1  
(SS1)  
DC  
Power  
Closed  
Conn-  
ection  
for  
DC  
No  
Return Output  
No  
Output  
Fault  
Indicator  
or  
Cool  
Mode  
1st  
on call  
for  
Heat  
supply  
voltage  
to re-  
24 VAC  
Com-  
mon  
Remote  
Temp-  
erature  
Sensor  
signal  
Energiz-  
ed in  
Ener-  
gized  
in Heat  
Mode  
to  
Required for fault or malfunc-  
tion indication, remote temper-  
ature sensor, or for continuous  
backlight operation.  
24 VAC  
(Hot)  
Heat  
24 VAC  
(Hot)  
Cool  
Remote  
Te mp-  
System  
Malfunc-  
tion  
Stage  
(Com-  
pressor)  
Cool &  
Off  
Mode  
call for  
Cool &  
for Heat  
(if ELE  
is sel-  
mote  
(option-  
al) *  
Cool  
mode  
2nd  
Te mp-  
erature  
Sensor  
Heat  
Mode  
1st  
3-wire  
zone  
valve  
Heat  
Mode  
2nd  
erature  
Sensor  
Multi-  
Stage 2  
(MS2)  
Comfort  
Alert II module  
or similar  
Switch  
Stage  
(Com-  
pressor)  
Stage  
Stage  
malfunction  
module  
ected)  
NEUTRAL  
24VAC  
HOT  
120VAC  
CLASS II  
TRANSFORMER  
Figure 3 – Single Stage or Multi-Stage System (No Heat Pump) with Two Transformers  
To Remote Temperature Sensor  
NOTE: If continuous backlight or hardwired  
power input are desired but do not function  
in both HEAT and COOL modes, cut the  
heating transformer 24V wires and tape off.  
Connect the neutral circuit disconnected  
from the heating transformer to the neutral  
circuit of the cooling transformer. Discon-  
nect the wire to the RH terminal and install  
a jumper between RH and RC. Depending  
on the system requirements, replace the  
cooling transformer with a 75VA class II  
transformer if needed.  
B
O
RC  
+
Y2  
Y
G
RH  
C
S
-
W2 W/E  
6
L
System  
Blower/  
Circula-  
tor Fan  
Energiz-  
ed on  
Ener-  
Single  
Stage 1  
(SS1)  
gized  
on call  
for  
DC  
No  
Output  
DC  
Return  
to  
No  
Output  
Power  
Closed  
Conn-  
ection  
for  
Cool  
Mode  
1st  
supply  
voltage  
to re-  
Fault  
Indicator  
or  
24 VAC  
Com-  
mon  
Remote  
Temp-  
erature  
Sensor  
signal  
Energiz-  
ed in  
Ener-  
gized  
in Heat  
Mode  
24 VAC  
(Hot)  
Heat  
24 VAC  
(Hot)  
Cool  
Heat  
Remote  
Te mp-  
erature  
Sensor  
Cool &  
Off  
Mode  
call for  
Cool &  
for Heat  
(if ELE  
is sel-  
Stage  
(Com-  
pressor)  
mote  
System  
Malfunc-  
tion  
(option-  
al) *  
Cool  
mode  
2nd  
Heat  
Mode  
2nd  
Temp-  
erature  
Sensor  
Heat  
Mode  
1st  
Multi-  
Stage 2  
(MS2)  
3-wire  
zone  
valve  
Comfort  
Alert II module  
or similar  
Switch  
Stage  
(Com-  
pressor)  
Stage  
Stage  
ected)  
malfunction  
module  
NEUTRAL  
24VAC  
HOT  
120VAC  
NEUTRAL  
24VAC  
HOT  
120VAC  
COOLING  
CLASS II  
TRANSFORMER  
HEATING  
CLASS II  
TRANSFORMER  
PART NO. 37-6808C  
Replaces 37-6808B  
0808  
GeneralDetails
NameWHITE-RODGERS 1F95-1277 Universal Thermostat Owner’s Manual
MakeWHITE RODGERS
LanguageEnglish
FiletypePDF (Download)
File size0.19 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
White-Rodgers 1E78 Non Programmable Heat Only Thermostat User Manual
White-Rodgers 1E78 Non Programmable Heat Only Thermostat User Manual
White-Rodgers 1F97-1277 Big Blue Single Stage Thermostat User Manual
White-Rodgers 1F97-1277 Big Blue Single Stage Thermostat User Manual
White-Rodgers 1F56N-444 Thermostat User Manual
White-Rodgers 1F56N-444 Thermostat User Manual
White-Rodgers 1F83-277 Heating & Air Conditioning Auto Changeover Heat Pump Thermostat User Manual
White-Rodgers 1F83-277 Heating & Air Conditioning Auto Changeover Heat Pump Thermostat User Manual
White-Rodgers M30 Thermostat Instruction Manual
White-Rodgers M30 Thermostat Instruction Manual
WHITE-RODGERS 1F51N-619 Low Voltage Evaporative Cooler Thermostat Instruction Manual
WHITE-RODGERS 1F51N-619 Low Voltage Evaporative Cooler Thermostat Instruction Manual
White Rodgers 1F78-151 Non Programmable Thermostat Instructions
White Rodgers 1F78-151 Non Programmable Thermostat Instructions
WHITE RODGERS 1F80-51 Programmable Electronic Digital Thermostat Instruction Manual
WHITE RODGERS 1F80-51 Programmable Electronic Digital Thermostat Instruction Manual
WHITE-RODGERS 1F86-0471 Blue Single 1 1 Stage Thermostat Instruction Manual
WHITE-RODGERS 1F86-0471 Blue Single 1 1 Stage Thermostat Instruction Manual
WHITE-RODGERS 1F90-71 5-Day 2-Day Electronic Digital Thermostat Instruction Manual
WHITE-RODGERS 1F90-71 5-Day 2-Day Electronic Digital Thermostat Instruction Manual

WHITE-RODGERS 1F95-1277 Universal Thermostat Owner’s Manual
Get the free PDF manual for the WHITE-RODGERS 1F95-1277 Universal Thermostat Owner’s Manual and access setup steps, usage instructions, and troubleshooting tips. 👉 View online or download now to keep your thermostat running smoothly!

WHITE-RODGERS 1F95-1277 Universal Thermostat Owner’s Manual Overview

Summary of Contents

  • Page 1: 90 Series Blue Universal Thermostat Wiring diagrams for 1F95-1277 Single stage, multi-stage, heat pump If you do not have a heat pump system, refer to figures 2 & 3. Refer to equipment manufacturers' instructions for specific system wiring information. After wiring, see installer configuration section for proper thermostat configuration. You can configure the thermostat for use with the following heat pump systems. This thermostat is designed to operate a single-transformer or two-transformer system. After wiring, see installer configuration section for proper thermostat configuration. Required for fault or malfunction indication, remote temperature sensor, or for continuous backlight operation.
  • Page 2: Diagramas de conexiones del termostato universal Blue serie 90 para 1F95-1277. Conexiones de la bomba de calor. Si no tiene un sistema de bomba de calor, refiérase a las figuras 2 y 3. Puede configurar el termostato para utilizarlo con los siguientes sistemas de bombas de calor. Sistema de compresor de una sola etapa; sistema auxiliar de gas o eléctrico. Sistema de compresor multietapa o de dos compresores con sistema de gas o eléctrico auxiliar. Después de conectar el termostato, vea en la sección INSTALLER CONFIGURATION cómo configurarlo correctamente. Este termostato está diseñado para operar un sistema de un solo transformador o de dos transformadores. Refiérase a las instrucciones del fabricante del equipo para ver información más específica sobre las conexiones. Si desea iluminación constante de la luz de fondo o alimentación de entrada con cableado interno pero no desea que el sistema funcione en los modos HEAT y COOL, corte los cables de 24 V del transformador de calefacción y encíntelos.