Home > WHITE RODGERS > White-Rodgers 1F83-277 Heating & Air Conditioning Auto Changeover Heat Pump Thermostat User Manual

White-Rodgers 1F83-277 Heating & Air Conditioning Auto Changeover Heat Pump Thermostat User Manual

WIRING DIAGRAMS  
NOTE  
Polarity must be observed. If the HOT side of the second transformer  
is jumpered to the COMMON side of the first transformer a short will  
be made. Damage to equipment will occur when power is restored.  
E/W1  
THERMOSTAT  
SYSTEM  
*
O
B
Y2  
Y1  
G
W2  
C
L
R
Limit or  
Safety  
Switches  
Limit or  
Safety  
Switches  
HOT  
Reversing  
Valve  
24 VAC  
120 VAC  
Emergency  
Heat  
Relay  
SYSTEM  
MONITOR  
SWITCH  
Reversing  
Valve  
2nd Stage  
Fan  
NEUTRAL  
Energized in  
Heat, Off,  
Emergency  
Mode  
Compressor  
Relay  
24 VAC  
Auxiliary  
Heating  
NOTE  
ACCESSORY  
RELAY N.O.  
CONTACT  
Energized in  
Cool Mode  
Aux  
Heat  
Relay  
Transformer  
(Class II  
Current Limited)  
The accessory relay scheme  
is required when safety  
circuits exist in both systems.  
Compressor  
Contactor  
COMMON  
TWO COMMONS MUST  
BE JUMPERED TOGETHER!  
Limit or  
Safety  
Switches  
Limit or  
Safety  
Switches  
HOT  
24 VAC  
120 VAC  
COMMON  
NEUTRAL  
Heat Pump Transformer  
(Class II Current Limited)  
Figure 4.Typical wiring diagram for two transformer heat pump systems with safety circuits in BOTH systems  
*The 24 volt neutral connection to terminal C on the thermostat is not required if you replace the batteries once a year with fresh “AA” alkaline batteries.  
Heat Pump Terminal Outputs  
Refer to equipment manufacturers' instructions for specific one transformer. If transformer safety circuits are in only one of  
system wiring information.  
the systems, remove the transformer of the system with NO  
safety circuits. If required, replace remaining transformer with a  
75VAClassIItransformer. Afterdisconnectingonetransformer,  
the two commons must be jumpered together.  
You can configure the thermostat for use with the following  
heat pump system types:  
HEAT PUMP TYPE 1. Single stage compressor system; gas  
or electric backup.  
Use the terminal output information below to help you wire the  
thermostat properly for your heat pump system. After wiring,  
see CONFIGURATION section for proper thermostat configu-  
ration.  
This thermostat is designed to operate a single-transformer  
system. If you have a two-transformer system, cut and tape off  
THERMOSTAT TERMINALS (HEAT PUMP)  
W2 E/W1 Y2 Y1  
SYSTEM  
Heat  
Pump 1  
L
Fault  
Indicator (Common) (Hot) 2nd stage,  
or System  
Malfunction  
Switch  
C*  
R
G
Heat and Blower/Fan Energized Energized Energized  
O
B
24 Volt 24 Volt Heat Mode Emergency  
Mode  
No  
Output Cool mode  
1st stage  
2nd  
stage  
compressor  
on call for Heat  
and Cool  
(compressor) Set GAS/ELEC switch  
for Emergency mode  
in Cool  
Mode  
in Heat  
OFF  
Emergency 1st stage  
Mode 2nd  
stage  
Heat  
Pump 2  
Emergency  
mode  
Heat Mode  
3rd stage,  
Emergency  
Mode 2nd  
stage  
*The 24 volt neutral connection to terminal C on the thermostat is not required if you replace the batteries once a year with fresh “AA” alkaline batteries.  
E/W1  
THERMOSTAT  
*
Y2  
W2  
C
R
B
Y1  
G
O
SYSTEM  
Heat  
Relay  
Compressor  
Contactor  
Stage 2  
Reversing  
Valve  
Reversing  
Valve  
Stage 1  
Hot  
120 VAC  
Energized in  
Heat Mode  
Off Emergency  
24 VAC  
Energized in  
Cool Mode  
Compressor  
Contactor  
Stage 1  
Heat  
Relay  
Neutral  
TRANSFORMER  
(Class II, Current Limited)  
Fan  
Relay  
Stage 2  
Figure 5.Typical wiring diagram for single transformer multi-stage systems  
*The 24 volt neutral connection to terminal C on the thermostat is not required if you replace the batteries once a year with fresh “AA” alkaline batteries.  
GeneralDetails
NameWhite-Rodgers 1F83-277 Heating & Air Conditioning Auto Changeover Heat Pump Thermostat User Manual
MakeWHITE RODGERS
LanguageEnglish
FiletypePDF (Download)
File size0.24 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
White-Rodgers 1E78 Non Programmable Heat Only Thermostat User Manual
White-Rodgers 1E78 Non Programmable Heat Only Thermostat User Manual
White-Rodgers 1F97-1277 Big Blue Single Stage Thermostat User Manual
White-Rodgers 1F97-1277 Big Blue Single Stage Thermostat User Manual
White-Rodgers 1F56N-444 Thermostat User Manual
White-Rodgers 1F56N-444 Thermostat User Manual
White-Rodgers M30 Thermostat Instruction Manual
White-Rodgers M30 Thermostat Instruction Manual
WHITE-RODGERS 1F51N-619 Low Voltage Evaporative Cooler Thermostat Instruction Manual
WHITE-RODGERS 1F51N-619 Low Voltage Evaporative Cooler Thermostat Instruction Manual
White Rodgers 1F78-151 Non Programmable Thermostat Instructions
White Rodgers 1F78-151 Non Programmable Thermostat Instructions
WHITE RODGERS 1F80-51 Programmable Electronic Digital Thermostat Instruction Manual
WHITE RODGERS 1F80-51 Programmable Electronic Digital Thermostat Instruction Manual
WHITE-RODGERS 1F86-0471 Blue Single 1 1 Stage Thermostat Instruction Manual
WHITE-RODGERS 1F86-0471 Blue Single 1 1 Stage Thermostat Instruction Manual
WHITE-RODGERS 1F90-71 5-Day 2-Day Electronic Digital Thermostat Instruction Manual
WHITE-RODGERS 1F90-71 5-Day 2-Day Electronic Digital Thermostat Instruction Manual
WHITE-RODGERS 1F95-1277 Universal Thermostat Owner’s Manual
WHITE-RODGERS 1F95-1277 Universal Thermostat Owner’s Manual

White-Rodgers 1F83-277 Heating & Air Conditioning Auto Changeover Heat Pump Thermostat User Manual