Home > FRICO > FRICO TPT16, TPT16WF Thermostat Instruction Manual

FRICO TPT16, TPT16WF Thermostat Instruction Manual

EN  
TPT16 / TPT16WF  
Release the front cover by pressing with  
Installation and operating instructions  
screwdriver from the ejector latch at the  
bottom of the thermostat. Open the spring and  
remove the frame.  
Wires must be stripped 9-10 mm. Wires can be  
released by pressing the connector’s release  
pin. Floor sensor must be placed into protective  
tube in concrete. Make sure there is no water in  
the tube.  
Setup  
This manual describes the most essential  
functions and technical specifications of the  
thermostat. These instructions help the user to  
control the thermostat, and the electrician to  
install and setup the thermostat.  
Now connect the wires to the thermostat’s  
terminals:  
PILOT:  
LOAD (N):  
N:  
Pilot Wire (if applicable)  
Heating Cable connection (Neutral)  
Power connection (Neutral)  
Power connection (Live)  
L:  
Technical specifications  
Heating Cable connection (Live)  
Floor temp sensor NTC type  
LOAD (L):  
SENSOR:  
Display: 1.8” TFT, 128x160 resolution  
Power supply: 230V - 50/60 Hz  
Maximum load: 16A (resistive)  
Setpoint temperature range: +5 °C/+40 °C  
Usage temperature range: 0 °C/+40 °C  
Temperature setback: Pilot wire 230V - 50/60 Hz  
IP class: IP21  
Standard Color: White RAL9003  
Sensors: Built-in room sensor and floor sensor  
NTC 10kΩ included  
Wi-Fi: 2.4GHz 802.11bgn (TPT16WF)  
Approvals: EN 60730-1, EN 60730-2-9,  
EN 300 328 V2.2.2  
Installation  
Installation must be done by a qualified  
electrician in accordance with wiring and  
building regulations.  
Before installation, disconnect any power to the  
thermostat’s mains. During installation of the  
thermostat, power to the thermostat must be  
disconnected or isolated AT ALL TIMES!  
Next, position the thermostat and fasten it onto  
the wall’s mounting box using 2-4 screws. Open  
the frame retaining spring, position the frame  
and close the spring. Then attach front part,  
make sure the connector between front and  
bottom part is correctly placed. Press front part  
until it snaps in place. Front part can later be  
removed by pressing the ejector latch.  
1
GeneralDetails
NameFRICO TPT16, TPT16WF Thermostat Instruction Manual
MakeFRICO
LanguageEnglish
FiletypePDF (Download)
File size0.14 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
FRICO TD10 Electronic Thermostat Instructions
FRICO TD10 Electronic Thermostat Instructions
FRICO TAP16R Electronic Thermostat User Guide
FRICO TAP16R Electronic Thermostat User Guide

FRICO TPT16, TPT16WF Thermostat Instruction Manual
Get the free PDF manual for the FRICO TPT16, TPT16WF Thermostat Instruction Manual and access setup steps, usage instructions, and troubleshooting tips. 👉 View online or download now to keep your thermostat running smoothly!

Frico TPT16, TPT16WF Manual: Questions and Answers

Frico TPT16, TPT16WF specifications

Power supply230V - 50/60 Hz
Maximum load16A (resistive)
Setpoint range+5 °C/+40 °C
SensorFloor temp sensor NTC type
IP ratingIP21
Wi-Fi2.4GHz 802.11bgn (TPT16WF)

Full specifications, page 1

What does the wooden floor temperature limit symbol mean on Frico TPT16?

Wooden floor has reached the maximum temperature of 27°C, so heating is being limited. Instruction Manual, p. 2

What do the symbols on the Frico TPT16, TPT16WF main screen represent?

SymbolMeaning
TimeCurrent time displayed
Operation modeHome, Away, Schedule, Anti-frost, or Power regulation
Wi-Fi indicatorConnection status (TPT16WF only)
Heating switchedHeating is currently on
SetpointTarget temperature setting
Measured tempRoom or floor sensor reading

Instruction Manual, p. 2

What's the difference between Home mode and Away mode?

Home uses a pre-set temperature you can change and save. Away uses a reduced pre-set temperature, also changeable and saved. Instruction Manual, p. 3

Can I set up Frico TPT16, TPT16WF to follow a daily schedule automatically?

Yes. Create customized daily schedules with up to five setpoints per day, each with a target time and temperature. The thermostat will regulate automatically according to the programmed schedule. Instruction Manual, p. 3

Frico TPT16, TPT16WF compared with other floor heating thermostats

SpecificationFrico TPT16, TPT16WFEtherma 3 set 2024Heat-my-home HMH200Heatit Z-TRM6 DC Z Wave
Power supply230V - 50/60 Hz230 V - 50/60 Hz85-240 V / 50-60 Hz230VAC 50Hz
Maximum load16A (resistive)16 A (ohmic)3600 W (16A)3A 24VDC
Setpoint range+5 °C/+40 °C+ 5 °C / + 35 °C+5° C ... +40° C5°C to 40°C
SensorFloor temp sensor NTC type10 k Ohm10 KΩ @25°C, length 3mNTC type 6.8, 10, 12, 15, 22, 33, 47 or 100kΩ
IP ratingIP21IP 21IP21IP21