Release the front cover by pressing with
Installation and operating instructions
screwdriver from the ejector latch at the
bottom of the thermostat. Open the spring and
remove the frame.
Wires must be stripped 9-10 mm. Wires can be
released by pressing the connector’s release
pin. Floor sensor must be placed into protective
tube in concrete. Make sure there is no water in
the tube.
Setup
This manual describes the most essential
functions and technical specifications of the
thermostat. These instructions help the user to
control the thermostat, and the electrician to
install and setup the thermostat.
Now connect the wires to the thermostat’s
terminals:
PILOT:
LOAD (N):
N:
Pilot Wire (if applicable)
Heating Cable connection (Neutral)
Power connection (Neutral)
Power connection (Live)
L:
Technical specifications
Heating Cable connection (Live)
Floor temp sensor NTC type
LOAD (L):
SENSOR:
Display: 1.8” TFT, 128x160 resolution
Power supply: 230V - 50/60 Hz
Maximum load: 16A (resistive)
Setpoint temperature range: +5 °C/+40 °C
Usage temperature range: 0 °C/+40 °C
Temperature setback: Pilot wire 230V - 50/60 Hz
IP class: IP21
Standard Color: White RAL9003
Sensors: Built-in room sensor and floor sensor
NTC 10kΩ included
Wi-Fi: 2.4GHz 802.11bgn (TPT16WF)
Approvals: EN 60730-1, EN 60730-2-9,
EN 300 328 V2.2.2
Installation
Installation must be done by a qualified
electrician in accordance with wiring and
building regulations.
Before installation, disconnect any power to the
thermostat’s mains. During installation of the
thermostat, power to the thermostat must be
disconnected or isolated AT ALL TIMES!
Next, position the thermostat and fasten it onto
the wall’s mounting box using 2-4 screws. Open
the frame retaining spring, position the frame
and close the spring. Then attach front part,
make sure the connector between front and
bottom part is correctly placed. Press front part
until it snaps in place. Front part can later be
removed by pressing the ejector latch.
1
| General | Details |
|---|---|
| Name | FRICO TPT16, TPT16WF Thermostat Instruction Manual |
| Make | FRICO |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.14 MB |

FRICO TD10 Electronic Thermostat Instructions

FRICO TAP16R Electronic Thermostat User Guide

FRICO TPT16, TPT16WF Thermostat Instruction Manual Overview
Summary of Contents
- Page 1: Release the front cover by pressing with a screwdriver from the ejector latch at the bottom of the thermostat. Wires must be stripped 9-10 mm. Floor sensor must be placed into protective tube in concrete. This manual describes the most essential functions and technical specifications of the thermostat. Now connect the wires to the thermostat’s terminals. Technical specifications include a display of 1.8” TFT, 128x160 resolution and a power supply of 230V - 50/60 Hz. Installation must be done by a qualified electrician in accordance with wiring and building regulations. Before installation, disconnect any power to the thermostat’s mains. Position the thermostat and fasten it onto the wall’s mounting box using 2-4 screws. Front part can later be removed by pressing the ejector latch.
- Page 2: User manual Start-up After connecting the power to the thermostat for the first time, or after performing a factory reset, a start-up wizard will prompt the following questions. Control The thermostat is controlled directly or via App Frico TPT (TPT16WF). Set language Timezone compared to GMT Daylight saving in use Y/N Set current date & time Heating or cooling The thermostat has three touch sensitive capacitive buttons. Standby and Main screen When the thermostat remains untouched for a while, it will automatically go to standby screen. In the main screen, pressing the center button will access the main menu.
- Page 3: Anti-frost mode drops the setpoint to 7 °C for use in winter. The thermostat has three main modes: Home, Away, and Schedule. Create customized daily schedules to minimize energy consumption and maximize comfort. A set point is given a target set time and temperature for automatic regulation. Home mode allows users to set and save a preferred temperature while at home. Away mode sets a reduced temperature while users are away and can be changed by the user. The Open window function activates if the room temperature drops rapidly and deactivates after 30 minutes. Energy consumption statistics can be viewed and reset through the settings. Child Lock can be activated or deactivated by pressing the center button three times. Programming can also be done with the phone application (TPT16WF).
- Page 4: When the Add Thermostat operation is finalized, the thermostat will reboot. The Wi-Fi settings menu will offer the possibility to turn Wi-Fi OFF/ON. To change Wi-Fi network or password, use the Connect to cloud menu with the phone application’s Reconfigure Wi-Fi menu. Advanced settings are recommended only for expert users. Incorrect settings may damage your floor or heating system. The advanced settings menu contains items such as heating setup, NTC type, and calibration. Packaging materials are recyclable and chosen with consideration to the environment. The product should not be disposed of with general household waste but delivered to a designated collection point for environmental recycling. The thermostat will automatically start/stop heating proactively to reach the set temperature at the set time if adaptivity is enabled. When the thermostat is not connected to the cloud, Connect to cloud can be started from the Wi-Fi settings menu.