Home > Honeywell > Honeywell RTHL2510 Series Programmable Thermostat Owner’s Manual

Honeywell RTHL2510 Series Programmable Thermostat Owner’s Manual

RTHL2510/RTHL2410  
Programmable  
Thermostat  
Series  
Owner’s Manual  
Read and save these  
instructions.  
For help please visit  
yourhome.honeywell.com  
Identify System Type  
This thermostat is compatible with the following systems:  
Gas, oil or electric furnace  
Central air conditioner  
Hot water system with or without pump  
Millivolt system  
Central heating and cooling system  
Heat pump without auxiliary/backup heat  
Heat pump with auxiliary/backup heat  
Do you need assistance? We are here to help.  
Call 1-800-468-1502 for wiring assistance before returning  
the thermostat to the store.  
This thermostat cannot be used on multistage systems.  
firealarmresources.com  
GeneralDetails
NameHoneywell RTHL2510 Series Programmable Thermostat Owner’s Manual
MakeHoneywell
LanguageEnglish
FiletypePDF (Download)
File size0.8 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
Honeywell T6 Pro Programmable Thermostat User Manual
Honeywell T6 Pro Programmable Thermostat User Manual
Honeywell D1-528 Direct Thermostat Installation Guide
Honeywell D1-528 Direct Thermostat Installation Guide
Honeywell FocusPRO P200 Programmable Thermostat User Guide
Honeywell FocusPRO P200 Programmable Thermostat User Guide
Honeywell RCHT8610WF Series Smart Thermostat Installation Guide
Honeywell RCHT8610WF Series Smart Thermostat Installation Guide
Honeywell T9 Smart Thermostat Installation Guide
Honeywell T9 Smart Thermostat Installation Guide
Honeywell TH2320WF4011 FocusPRO Smart S200 Series Thermostat User Guide
Honeywell TH2320WF4011 FocusPRO Smart S200 Series Thermostat User Guide
Honeywell TL116A Thermostat Installation Guide
Honeywell TL116A Thermostat Installation Guide
T10 Pro Smart Thermostat with Redlink Room Sensor
T10 Pro Smart Thermostat with Redlink Room Sensor
Honeywell TH6320WF2003 Lyric T6 Pro Wi-Fi Programmable Thermostat User Guide
Honeywell TH6320WF2003 Lyric T6 Pro Wi-Fi Programmable Thermostat User Guide
Honeywell RTH9580 Wi-Fi Color Touchscreen Programmable Thermostat User Guide
Honeywell RTH9580 Wi-Fi Color Touchscreen Programmable Thermostat User Guide

Honeywell RTHL2510 Series Programmable Thermostat Owner’s Manual
Get the free PDF manual for the Honeywell RTHL2510 Series Programmable Thermostat Owner’s Manual and access setup steps, usage instructions, and troubleshooting tips. 👉 View online or download now to keep your thermostat running smoothly!

Honeywell RTHL2510 Series Programmable Thermostat Owner’s Manual Overview

Summary of Contents

  • Page 1: Programmable thermostat series owner’s manual. Read and save these instructions. This thermostat is compatible with the following systems: gas, oil or electric furnace, central air conditioner, hot water system with or without pump, millivolt system, central heating and cooling system, heat pump without auxiliary/backup heat, heat pump with auxiliary/backup heat. This thermostat cannot be used on multistage systems.
  • Page 2: Attention: Mercury recycling notice This product does not contain mercury. This product may replace a product that contains mercury. Mercury and products containing mercury should not be discarded in household trash. For more information on how and where to properly recycle a thermostat containing mercury in the United States, please refer to the Thermostat Recycling Corporation. For mercury thermostat recycling in Canada, please refer to Switch the Stat. Notice: To avoid possible compressor damage, do not run air conditioner if the outside temperature drops below 50°F (10°C). For assistance with this product, please visit the Honeywell website. To save time, please note your model number and date code before calling. Pull at bottom to remove thermostat from wallplate.
  • Page 3: Table of contents Installation Programming and operation Setting the clock Adjusting program schedules Overriding schedules temporarily Overriding schedules permanently Compressor protection Early Start Replace batteries About your new thermostat Controls and Home screen
  • Page 4: Remove old thermostat but leave wallplate with wires attached. If you have an older thermostat with a sealed mercury tube, turn to page 2 for proper disposal instructions. Label the wires using the supplied wire labels as you disconnect them. Remove wallplate from the new thermostat and mount onto wall. Pull here to remove wallplate.
  • Page 5: Mount the new wallplate using the included screws and anchors. Drill 3/16-in. holes for drywall. Drill 3/32-in. holes for plaster. Simply match wire labels. If labels do not match letters on the thermostat, check “Alternate Wiring (Conventional Systems)” on page 6. Remove metal jumper if you have both R and Rc wires. Insert wires and tighten screws. We are here to help.
  • Page 6: Alternate wiring for conventional systems requires checking the chart for terminal connections. If wires connect to both R and Rc terminals, remove the metal jumper. Do not use C or X; wrap the bare end of the wire with electrical tape. For heat pumps without auxiliary/backup heat, connect either O or B, not both. If there is no heat pump, do not connect B; wrap the bare end of the wire with electrical tape. Place a jumper between Y and W for heat pumps without auxiliary/backup heat. Alternate wiring for heat pumps also refers to the terminal labels.
  • Page 7: Alternate wiring for heat pumps with auxiliary or backup heat only. If labels do not match letters on the thermostat, check the chart below and connect to terminal as shown. Leave metal jumper in place, connecting R and Rc terminals. If your old thermostat had both V and VR wires, stop now and contact a qualified contractor for help. If your old thermostat had separate O and B wires, wrap the B wire in electrical tape and do not connect. Do not use C or X wire. Wrap bare end of wire with electrical tape. If your old thermostat had E and Aux wires, connect both wires to Aux terminal. Install two AAA alkaline batteries.
  • Page 8: Set fan operation switch to the proper setting. For gas or oil heating systems, leave the fan operation switch in the factory-set position. Change the switch to the setting for heat pump or electric heat systems. Install thermostat onto the wallplate on the wall. Turn the power back on to the heating/cooling system.
  • Page 9: If your system type is single stage heat and cool, congratulations, you’re done. If your system type is heat pump with backup heat, continue with advanced installation to match your thermostat to your system type. This thermostat works on 24 volt or 750 mV systems. It will not work on multi-stage conventional systems. To enter system setup, press and hold both the s and t buttons until the display changes. Press the s or t button to change the setting. Press the s and t buttons simultaneously for one second to advance to the next function. Press the RUN button to exit and save settings.
  • Page 10: If you do not press any button for 60 seconds while you are in the setup menu, the thermostat automatically saves any changes made and exits the menu. Your new Honeywell thermostat has been designed to give you many years of reliable service and easy-to-use, push-button climate control. The backlit display is easy to read. It displays ambient (measured) temperature at all times. There is one-touch access to setpoint temperature. The thermostat features preset program settings. It allows temporary and permanent override of schedule. Early start ensures the right temperature at the right time. Built-in compressor protection prevents equipment damage.
  • Page 11: Thermostat controls Set: Press to set time/day/schedule. Temperature adjustment: Press the up or down buttons until you reach the desired temperature. Hold: Press to override programmed temperature control. NOTE: Make sure the system switch is set to the system you want to control (Heat or Cool). Run: Press to resume program schedule. Fan: Auto On, Heat Off, Cool. The system switch is used to control your heating or cooling system. In “Auto” mode, the fan runs only when the heating or cooling system is on. Heat: Heating system control. Cool: Cooling system control. Display screen: Setpoint indicator appears when the setpoint temperature is displayed.
  • Page 12: Set the time and day Press the SET button, then press s or t to set the clock time. Press the SET button, then press s or t to select the day of the week. Press RUN to save & exit. If the clock flashes, the thermostat will follow your settings for the Monday “Wake” time period until you reset the time and day. You can program four time periods each day, with different settings for weekdays and weekends. Wake - Set to the time you awaken and the temperature you want during the morning. Leave - Set to the time you leave home and the temperature you want while you are away. Return - Set to the time you return home and the temperature you want during the evening. Sleep - Set to the time you go to bed and the temperature you want overnight. Leave and Return periods can be canceled on weekends.
  • Page 13: To adjust program schedules (RTHL2510) Press SET until Set Schedule is displayed. Press s or t to set your Wake time for the day displayed, then press SET. Press s or t to set the temperature for this time period, then press SET. Set time and temperature for the next time period (Leave). Repeat steps 2 and 3 for each day’s time period. Press RUN to save & exit. Make sure the thermostat is set to the system you want to program (Heat or Cool). To adjust program schedules (RTHL2410) Press SET until Set Schedule is displayed. Press s or t to set your weekday Wake time (Mo-Fr), then press SET. Press s or t to set the temperature for this time period, then press SET. Set time and temperature for the next time period (Leave). Repeat steps 2 and 3 for each weekday time period.
  • Page 14: Program schedule override (temporary) Press s or t to immediately adjust the temperature. This will temporarily override the temperature setting for the current time period. “Temporary” will appear on the display and the current program period will flash. The new temperature will be maintained only until the next programmed time period begins. To cancel the temporary setting at any time, press RUN. Make sure the thermostat is set to the system you want to control (heat or cool). Program schedule override (permanent) Press HOLD to permanently adjust the temperature. This will override the temperature settings for all time periods. The “Hold” feature turns off the program schedule and allows you to adjust the thermostat manually, as needed. Whatever temperature you set will be maintained 24 hours a day, until you manually change it, or press RUN to cancel “Hold” and resume the program schedule. Make sure the thermostat is set to the system you want to control (heat or cool).
  • Page 15: Built-in compressor protection helps prevent damage to the compressor in your air conditioning or heat pump system. Damage can occur if the compressor is restarted too soon after shutdown. This feature forces the compressor to wait 5 minutes before restarting. During the wait time, the display will flash the message Cool On (or Heat On if you have a heat pump). When the safe wait time has elapsed, the message stops flashing and the compressor turns on. Early Start allows the heating or cooling to turn on before the program start time, so the temperature is reached at the time you set. For example, if you set the Wake time to 6 am and the temperature to 70°, the heat will come on before 6 am, so the temperature is 70° by the time you wake at 6. The next time period is displayed when the system is activated before a scheduled time period.
  • Page 16: Battery replacement Install two fresh AAA batteries when Lo Batt flashes on the screen. Lo Batt appears for 60 days before the batteries are depleted. Pull at bottom to remove thermostat from wallplate. Replace batteries once a year, or when you will be away for more than a month. Most settings are stored in non-volatile (permanent) memory. Only the clock and the day must be set after you replace the batteries. Set the System switch to Off before removing the batteries. Otherwise, the heating/cooling system could remain activated even when batteries are removed. Turn thermostat over, insert fresh AAA alkaline batteries, then reinstall thermostat.
  • Page 17: Troubleshooting If you have difficulty with your thermostat, please try the following suggestions. Most problems can be corrected quickly and easily. Display is blank - Check circuit breaker and reset if necessary. - Make sure power switch at heating & cooling system is on. - Make sure furnace door is closed securely. - Make sure fresh AAA alkaline batteries are correctly installed. Heating or cooling system does not respond - Set system switch to Heat. Make sure the temperature is set higher than the inside temperature. - Set system switch to Cool. Make sure the temperature is set lower than the inside temperature. - Wait 5 minutes for the system to respond. Temperature settings do not change - Make sure heating and cooling temperatures are set to acceptable ranges: Heat: 40° to 90°F (4.5° to 32°C), Cool: 50° to 99°F (10° to 37°C). “Cool On” or “Heat On” is flashing - Compressor protection feature is engaged. Wait 5 minutes for the system to restart safely, without damage to the compressor. “Heat On” is not displayed - Set the System switch to Heat, and set the temperature level above the current room temperature. “Cool On” is not displayed - Set the System switch to Cool, and set the temperature level below the current room temperature.
  • Page 18: RTHL2510/RTHL2410 thermostat programmable Veuillez lire le mode d’emploi et le conserver en lieu sûr. Ce thermostat est compatible avec les systèmes suivants: À gaz, mazout ou électrique Climatiseur central Système à eau chaude avec ou sans pompe Système millivolts Système de chauffage-refroidissement central Thermopompe sans chauffage de secours/auxiliaire Thermopompe avec chauffage de secours/auxiliaire Ce thermostat ne peut pas être utilisé sur les systèmes à plusieurs étages.
  • Page 19: Attention : avis relatif au recyclage du mercure Ce produit ne contient aucun mercure. Ce produit peut remplacer un produit qui contient du mercure. Le mercure et les produits contenant du mercure ne doivent pas être jetés aux ordures ménagères. Pour obtenir plus d’informations sur le recyclage d’un thermostat contenant du mercure aux États-Unis, consultez l’organisme de recyclage des thermostats. Pour le recyclage de thermostats contenant du mercure au Canada, consultez l’organisme Switch the Stat. Avis : pour éviter d’endommager le compresseur, ne faites pas fonctionner le climatiseur si la température extérieure est inférieure à 10 °C (50 °F). Services à la clientèle : pour obtenir de l’aide avec ce produit, consultez le site. Veuillez prendre en note le numéro de modèle et de code de date du thermostat avant d’appeler. Retourner le thermostat pour trouver le numéro de modèle et le code de date.
  • Page 20: Installation Programmation et fonctionnement Réglage de l’horloge Réglage des programmes Dérogation temporaire Guía de instalación avanzada Dérogation permanente Protection du compresseur Démarrage précoce Remplacement des piles
  • Page 21: Retirer l’ancien thermostat, mais laisser en place la plaque murale et les fils sans les détacher. Si vous possédez un thermostat plus ancien à tube de mercure scellé, allez à la page 2 pour les instructions de mise au rebut correctes. Étiqueter les fils à l’aide des étiquettes fournies à mesure que les fils sont débranchés. Retirer la plaque murale du nouveau thermostat et l’installer au mur.
  • Page 22: Installer la nouvelle plaque murale à l’aide des vis et des chevilles d’ancrage fournies. Percer des trous de 3/16 po si le mur est en placoplâtre. Percer des trous de 3/32 po si le mur est en plâtre. Il suffit ensuite de faire correspondre les fils avec les étiquettes. Si les étiquettes ne correspondent pas aux lettres du thermostat, consulter “Autre option de câblage (Système conventionnel)”. Retirer le cavalier en métal s’il y a à la fois les fils « R » et « Rc ». Insérer les fils et serrer les vis. Composer le 1-800-468-1502 pour obtenir de l’aide au cours du raccordement.
  • Page 23: Autre option de câblage (Système conventionnel) Si les étiquettes ne correspondent pas aux lettres sur le thermostat, consulter le tableau ci-dessous. Ne pas connecter W/ NOT R. Si des fils seront raccordés aux bornes R et Rc, enlever le cavalier en métal. Ne pas se servir de C ou X. Si une thermopompe est installée sans chauffage auxiliaire/de secours, connecter O ou B mais pas les deux. Placer un cavalier entre Y et W si une pompe thermique est utilisée sans chauffage auxiliaire/de secours. Autre option de câblage (Thermopompe) Se reporter à la page 7 si les étiquettes ne correspondent pas aux lettres marquées sur le thermostat.
  • Page 24: Autre option de câblage pour les thermopompes avec chauffage auxiliaire ou de secours uniquement. Si les étiquettes ne correspondent pas aux lettres sur le thermostat, consulter le tableau ci-dessous et faire le branchement aux bornes comme illustré ici. Laisser le cavalier métallique en place en connectant les bornes R et Rc. Si l’ancien thermostat est muni de fils V et VR, s’arrêter immédiatement et contacter un installateur qualifié pour obtenir de l’aide. Si l’ancien thermostat a des fils O et B séparés, enrouler le fil B dans du ruban électrique sans le brancher. Ne pas utiliser les fils C ou X. Ne pas utiliser le fil B si un fil O est déjà présent. Installer 2 piles alcalines AAA à l’arrière du thermostat.
  • Page 25: Réglages du ventilateur Placer le sélecteur à la position qui correspond au système. S’il s’agit d’un système de chauffage au gaz ou au mazout, laisser le sélecteur à la position réglée en usine. Déplacer le commutateur à la position électrique ou thermopompe si le système est une thermopompe ou un appareil de chauffage électrique. Fixer le thermostat à la plaque murale Installer le thermostat sur la plaque murale fixée au mur. Rétablir l’alimentation électrique Rétablir l’alimentation électrique du système de chauffage-refroidissement.
  • Page 26: Si votre système est du type suivant: Chauffage et refroidissement à un étage Chauffage uniquement ou refroidissement uniquement Si votre système est du type suivant: Thermopompe avec chauffage de secours Passer au mode d’installation avancé pour faire correspondre le thermostat à votre type de système. Ce thermostat convient aux systèmes alimentés par du courant 24 volts ou 750 millivolts. Guide d’installation avancé Entrer les réglages du système Modifier les réglages Appuyer sur le bouton RUN pour enregistrer les modifications et quitter le mode de réglage.
  • Page 27: Si aucun bouton n’est touché pendant 60 secondes dans le menu de configuration, le thermostat enregistre automatiquement toute modification effectuée et quitte le menu. Appuyer sur les touches pour sélectionner le type de système. Chauffage et refroidissement : chauffage à gaz, mazout ou électrique avec climatisation centrale ou thermopompe sans chauffage auxiliaire/de secours. Thermopompe avec chauffage auxiliaire/de secours : le compresseur extérieur fournit le chauffage et le refroidissement. Système de chauffage au gaz ou au mazout : utiliser ce réglage si le système de chauffage est un modèle standard avec une efficacité inférieure à 90 %. Système de chauffage électrique : utiliser ce réglage pour tout type de système de chauffage électrique. Sélectionnez démarrage précoce. Choisir d’afficher la température en Fahrenheit ou en Celsius. Protection du compresseur : cette fonction force le compresseur à attendre environ 5 minutes avant de se remettre en marche pour éviter d’endommager l’équipement. Votre nouveau thermostat Honeywell a été conçu pour vous procurer de nombreuses années de service fiable et assurer la régulation de la température ambiante avec facilité.
  • Page 28: Commandes de thermostat Set : Appuyer sur cette touche pour régler l’heure/le jour/l’horaire. Réglage de la température : Appuyer sur les touches haut ou bas jusqu’à l’obtention de la température désirée. Hold : Appuyer sur cette touche pour déroger au programme. Run : Appuyer sur cette touche pour revenir au programme. La commande SYSTEM (système) est utilisée pour commander le système de chauffage ou de refroidissement. Heat : Commande le système de chauffage. Off : Tous les systèmes sont à l’arrêt. Cool : Commande le système de refroidissement. En mode de fonctionnement automatique (AUTO), le ventilateur fonctionne seulement quand le système de chauffage ou de refroidissement est en marche. Avertissement de piles faibles.
  • Page 29: Régler l’heure et le jour Appuyer sur le bouton SET, puis sur s ou t pour régler l’heure. Appuyer sur le bouton SET, puis sur s ou t pour choisir le jour de la semaine. Appuyer sur RUN pour enregistrer les réglages et quitter. Si l’horloge clignote, le thermostat respecte la consigne prévue pour la période de réveil jusqu’à ce que le jour et l’heure soient réglés. Dérogation au programme Vous pouvez programmer quatre périodes de temps par jour avec des réglages différents pour les jours de semaine et les fins de semaine. Wake (Lever) - Réglez à l’heure du lever et à la température voulue le matin. Leave (Départ) - Réglez à l’heure du départ de la maison et à la température voulue durant votre absence. Return (Retour) - Réglez à l’heure de votre retour à la maison et à la température que vous voulez durant la soirée. Sleep (Sommeil) - Réglez à l’heure du coucher et à la température voulue durant votre sommeil.
  • Page 30: Réglage de l’horaire (RTHL2510) Appuyer sur SET jusqu’à ce que « Set Schedule » apparaît à l’écran. Appuyer sur s ou t pour régler l’heure de réveil pour le jour affiché puis appuyer sur SET. Appuyer sur s ou t pour régler la température pour cette période puis appuyer sur SET. Régler la température et l’heure de la période suivante (Leave, ou départ). Appuyer sur RUN pour enregistrer les réglages et quitter. REMARQUE : S’assurer que le thermostat est réglé au système à mettre en marche (Heat ou Cool). Réglage de l’horaire (RTHL2410) Appuyer sur SET jusqu’à ce que « Set Schedule » apparaît à l’écran. Appuyer sur s ou t pour régler l’heure de réveil des jours de la semaine puis appuyer sur SET. Appuyer sur s ou t pour régler la température pour cette période puis appuyer sur SET. Régler la température et l’heure de la période suivante (Leave, ou départ). Appuyer sur SET pour régler les périodes de la fin de semaine, puis appuyer sur RUN pour enregistrer le programme et quitter. REMARQUE : S’assurer que le thermostat est réglé au système à mettre en marche (chauffage ou refroidissement).
  • Page 31: Dérogation (temporaire) au programme Cette fonction permet de déroger à la température de consigne de la période en cours. La nouvelle température de consigne restera en vigueur jusqu’au début de la prochaine période seulement. Pour annuler cette dérogation, il suffit d’appuyer à n’importe quel moment sur la touche RUN. S’assurer que le thermostat est réglé au système à mettre en marche (chauffage - Heat ou refroidissement - Cool). Dérogation (permanente) au programme Cette fonction permet de déroger à la température de consigne pour toutes les périodes. La fonction de maintien «Hold» met le programme hors service et permet d’ajuster le thermostat manuellement. Peu importe la température réglée, le thermostat maintiendra cette même température toute la journée (24 heures). S’assurer que le thermostat est réglé au système à mettre en marche (chauffage - Heat ou refroidissement - Cool).
  • Page 32: Protection intégrée du compresseur Cette fonction sert à éviter d’endommager le compresseur qui fait partie du système de refroidissement ou de la thermopompe. Le compresseur pourrait être endommagé s’il redémarre trop rapidement après avoir été mis à l’arrêt. Cette fonction oblige le compresseur à attendre 5 minutes avant de redémarrer. Pendant cette attente, les mots «Cool On» (ou «Heat On» si le système utilisé est une thermopompe) clignotent à l’écran. Lorsque le délai d’attente est écoulé, le message cesse de clignoter et le compresseur se met en marche. Démarrage précoce Cette fonction permet d’activer le chauffage ou le refroidissement avant l’heure programmée pour que la température souhaitée soit atteinte à l’heure indiquée. Par exemple : Régler l’heure de réveil à 6 heures et la température à 70 °. Le chauffage s’enclenche avant 6 heures, de sorte que la température ait atteint 70 °C lorsqu’on se réveille à 6 heures. La période suivante s’affiche lorsque le système est activé avant une période de temps programmée.
  • Page 33: Remplacement des piles Mettre deux piles AAA neuves lorsque Lo Batt (piles faibles) clignote à l’écran. Lo Batt s’affiche pendant 60 jours avant que les piles ne soient complètement déchargées. Tirer le thermostat par le bas pour le détacher de la plaque murale. Remplacer les piles une fois par an ou avant de quitter la maison pour une période de plus d’un mois. La plupart des réglages sont sauvegardés dans la mémoire non volatile (permanente). Seuls l’horloge et le jour doivent être réglés après le remplacement des piles. Mettre la commande System (Système) sur Off (Arrêt) avant de retirer les piles. Dans le cas contraire, le système de chauffage/refroidissement pourrait rester activé même si les piles sont retirées. Retourner le thermostat et installer des piles alcalines AAA neuves.
  • Page 34: Dépannage En cas de difficultés avec le thermostat, essayer les suggestions suivantes. La plupart des problèmes peuvent être réglés rapidement et facilement. Rien n’apparaît à l’écran Vérifiez le disjoncteur et réinitialisez-le si nécessaire. Assurez-vous que l’interrupteur de marche-arrêt du système de chauffage et de refroidissement est sur marche. Assurez-vous que la porte de l’appareil de chauffage est bien fermée. S’assurer qu’il y a bien des piles alcalines AAA neuves en place. Le système de chauffage ou de refroidissement ne répond pas Régler le sélecteur du système à Heat. S’assurer que le point de consigne est plus élevé que la température ambiante. Régler le sélecteur du système à Cool. S’assurer que le point de consigne est moins élevé que la température ambiante. Attendre 5 minutes pour laisser au système le temps de réagir.