Home > Danfoss > Danfoss GreenCon RC-T2/T4 Room Thermostat Installation Guide

Danfoss GreenCon RC-T2/T4 Room Thermostat Installation Guide

Installation Guide  
GreenCon RC-T2/T4  
Room thermostat  
GeneralDetails
NameDanfoss GreenCon RC-T2/T4 Room Thermostat Installation Guide
MakeDanfoss
LanguageEnglish
FiletypePDF (Download)
File size0.7 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
Danfoss RET-MD Electronic Intelligent Dial Setting Thermostat Installation Guide
Danfoss RET-MD Electronic Intelligent Dial Setting Thermostat Installation Guide
Danfoss VICUQ24M Icon Programmable II Room Thermostat Installation Guide
Danfoss VICUQ24M Icon Programmable II Room Thermostat Installation Guide
Danfoss MBC 8000, MBC 8100 Heavy Duty Thermostat Installation Guide
Danfoss MBC 8000, MBC 8100 Heavy Duty Thermostat Installation Guide
Danfoss UT 72-UT 73 Universal Thermostat Installation Guide
Danfoss UT 72-UT 73 Universal Thermostat Installation Guide
Danfoss ECtemp 530 Electronic Thermostat Installation Guide
Danfoss ECtemp 530 Electronic Thermostat Installation Guide
Danfoss 014G0251 Eco Radiator Thermostat User Guide
Danfoss 014G0251 Eco Radiator Thermostat User Guide
Danfoss RET230P Electronic Thermostat Instruction Manual
Danfoss RET230P Electronic Thermostat Instruction Manual
Danfoss 014G0013 Z Wave Radiator Thermostat Installation Guide
Danfoss 014G0013 Z Wave Radiator Thermostat Installation Guide
Danfoss TP7000 Range Electronic 7 Day Programmable Room Thermostat Installation Guide
Danfoss TP7000 Range Electronic 7 Day Programmable Room Thermostat Installation Guide
Danfoss RET1000 Series Electronic Thermostat User Guide
Danfoss RET1000 Series Electronic Thermostat User Guide

Danfoss GreenCon RC-T2/T4 Room Thermostat Installation Guide
Get the free PDF manual for the Danfoss GreenCon RC-T2/T4 Room Thermostat Installation Guide and access setup steps, usage instructions, and troubleshooting tips. 👉 View online or download now to keep your thermostat running smoothly!

Danfoss GreenCon RC-T2/T4 Room Thermostat Installation Guide Overview

Summary of Contents

  • Page 1: Installation guide for GreenCon RC-T2/T4 room thermostat.
  • Page 2: Installation must be done by an authorised electrician. The room thermostat should be installed at approx. 1.5 m above floor and where the effects of sunlight, draught or other heat sources are avoided. Carefully remove the cover before installation. Connect the wire before mounting the back plate to the wall box using the enclosed screws. Mount the cover to the back plate after installation. Refer to the dimensions for installation guidance. Consult the wiring diagram for proper connections. Follow the illustrations to complete the wiring for RC-T4 and RC-T2. User guide can be downloaded from the specified website. Ensure all steps are followed for correct installation.
  • Page 3: Installation guide for GreenCon RC-T2/T4 includes error codes and descriptions. Error codes: E1 indicates a short circuit of the sensor. EE signifies an EEPROM chip error. Lo indicates a temperature lower than 0°C. Hi indicates a temperature higher than 50°C. Correct wiring is essential; confirming L and N before wiring is recommended. Avoid removing too much insulation from the wire to prevent short circuits. Ensure screws do not touch the wire when fixing the thermostat to avoid damage. Mount the thermostat after painting to prevent dust or paint from damaging the PCB. The maximum load of the relay is 3 A (resistive) or 1 A (inductive).
  • Page 4: Installation guide for GreenCon RC-T2/T4. The relay will be damaged if the load exceeds the limit. Don’t cover the thermostat, for instance by hanging towels directly in front of it. The room thermostat should be connected to the corresponding actuator and valve in individual room temperature control. Technical specifications include CE marking and EN60730 approval. Ambient temperature range is 0 - 45 °C. Max load for inductive is <1 A and for resistive is <3 A. Power consumption is 2 W with a power supply of 85-250 Vac, 50/60 Hz. Room temperature set range is 5 - 35 °C. Shell material is ABS + PC.
  • Page 5: Installation guide for GreenCon RC-T2/T4. Interface symbols description. Temperature indication. Valve temperature setting. Frost protection. Heating and eco mode. Cooling and keyboard lock. Timer ON/OFF and ventilation. Fan control and 5/2 4 event program. Actual weekday and clock.
  • Page 6: Installation guide for GreenCon RC-T2/T4 outlines key operational features. Power options include On/Off and Eco mode. To turn on, press the power button; to turn off, hold the button for 2 seconds. Eco mode can be accessed with a short press of the power button. Mode selection allows changing between cooling, heating, or ventilation. Temperature can be adjusted by pressing the corresponding buttons. The SET icon indicates when temperature setting is in progress. Fan speed can be selected from options including Low, Med, Hi, and Auto. In Auto mode, fan speed adjusts based on the temperature difference. Default setting for fan speed is Close when not in use.
  • Page 7: Installation guide for GreenCon RC-T2/T4. Time setting and ON/OFF timer instructions provided. Long press to start adjusting the hour, minute, and weekday. Timer On/OFF setting can be configured after time setting. Steps to adjust timer ON and OFF hours and minutes outlined. Instructions to cancel the ON/OFF timer function included. Keyboard lock feature mentioned. Details on parameter P11 for setting temperature referenced. Danfoss Heating Solutions noted as the manufacturer.
  • Page 8: Installation guide for GreenCon RC-T2/T4 includes instructions for locking and unlocking the keyboard, resetting the thermostat, and auto-switching between heating and cooling. To lock the keyboard, press and hold “M” and then short press “>” within 6 seconds. To reset the thermostat, press and hold both “M” and “<” and “>” for 10 seconds during power off. The auto switch between heating and cooling is controlled by parameters P16, P17, and P19. The temperature is managed by the set temperature, with the dead zone determined by parameters P16 for normal mode and P17 for ECO mode. For heating and cooling, if P18 is off, the fan is controlled by the fan speed selection. If P18 is on, the fan is disabled during heating and controlled by the fan speed selection during cooling. The programming feature allows for 5-2 day programming by configuring P01 to “02”. When enabled, the system automatically changes the setting temperature four times per day.
  • Page 9: Installation guide for GreenCon RC-T2/T4 includes instructions for modifying temperature settings and event times. The programming function allows users to define temperature settings for four time periods during workdays and weekends. Default setup includes starting times and temperatures for each period: 7:00 at 18°C/28°C, 9:00 at 22°C/26°C, 18:00 at 18°C/28°C, and 21:00 at 15°C/30°C. To program workday setup, long press the designated button for 5 seconds until the workday icon displays. Users can adjust the starting hour of the first event and confirm the selection. Adjustments can also be made for heating and cooling temperatures during the first event. This process should be repeated for the next three events. For weekend setup, after programming workdays, the weekend icon will appear on the screen. Users should repeat the steps to set starting time and temperature for weekends. GreenCon will automatically change the setting temperature according to the programmed setup.
  • Page 10: Installation guide for GreenCon RC-T2/T4 includes parameter setting instructions. To enter parameter setting mode, long press M for 6 seconds. Short press M to select a parameter and use < or > to adjust the value. Factory parameter definitions include programming options for on/off functions. The timer can be set to ON or OFF. Maximum room temperature can be set between 5-35°C, with a default of 30°C. Minimum room temperature can also be set between 5-35°C, with a default of 5°C. Frost protection can be activated or deactivated, with temperature settings ranging from 5-17°C. Default heating temperature is set at 20°C, while default cooling temperature is 25°C. ECO mode has a default heating temperature of 15°C.
  • Page 11: Installation guide for GreenCon RC-T2/T4 includes factory settings and parameter definitions. The default cooling temperature for ECO mode is set to 28°C with a range of 5-35°C. Fan speed settings are available for reaching the set temperature in DA/DB configuration. Clock settings can be adjusted for 24-hour or 12-hour formats. The display can show room temperature after being turned off, with options to enable or disable this feature. User setups can be saved when powered off. Auto switch settings allow for closing or opening between heating and cooling modes. Deadband settings for normal mode range from 0.5°C to 5°C, with a default of 1°C. ECO mode deadband settings range from 5°C to 10°C. Heating and cooling configurations include options for floor/radiator heating and fan coil cooling.
  • Page 12: Installation guide for GreenCon RC-T2/T4 includes factory settings and parameter definitions. The temperature setting range is between 5°C and 35°C. Auto switch settings are specified for heating and cooling modes. The startup status can be set to last known mode or standby. Parameters P15-P19 are exclusive to the GreenCon RC-T4 model.
  • Page 13: Installation guide for GreenCon RC-T2/T4. Installation must be performed by a qualified electrician. The indoor thermostat should be installed approximately 1.5 meters above the floor, avoiding sunlight, airflow, or other heat sources. Carefully remove the front cover before installation. Connect the wires using the included screws before securing the backplate to the junction box. Refer to the dimensions in the provided diagrams. Wiring terminals are illustrated in the accompanying diagrams. Follow the instructions for wiring specific to RC-T4 and RC-T2 models.
  • Page 14: Installation guide for GreenCon RC-T2/T4 includes important error codes and their meanings. Error codes indicate issues such as room temperature sensor failure and EEPROM failure. Warnings emphasize the importance of correct wiring and suggest verifying L and N before connection. Excessive removal of insulation from wires can lead to short circuits. Screws used to secure the indoor thermostat should not press against wires to avoid insulation damage. Install the indoor thermostat after painting to prevent dust or paint from damaging the PCB. The maximum load for the relay is 3 A for resistive loads and 1 A for inductive loads. Do not cover the thermostat to ensure proper functioning. For zoned temperature control, ensure the thermostat room corresponds with the valve circuit.
  • Page 15: Installation guide for GreenCon RC-T2/T4 includes technical parameters and features. The device is certified with CE mark and complies with EN60730 standards. Operating temperature ranges from 0 to 45 °C. The protection level is IP30. Maximum load for inductive load is less than 1 A and for resistive load is less than 3 A. Power consumption is 2 W. The power supply operates between 85-250 Vac at 50/60 Hz. The room temperature setting range is between 5 to 35 °C. The housing material is ABS + PC.
  • Page 16: Installation guide for GreenCon RC-T2/T4 includes a display interface section. The display shows various icons with specific meanings. Icons represent electric valve status, temperature display, and temperature setting. Different modes such as heating, cooling, and ventilation are indicated. Low temperature protection and energy-saving mode are also featured. The interface includes a keyboard lock and timer function. Wind speed display and clock are part of the interface. The programming section allows for 5/2 and 4 time periods. Weekday display is included in the programming options. Danfoss Heating Solutions is mentioned in the document.
  • Page 17: Installation guide for GreenCon RC-T2/T4 includes key operational instructions. Power on/off and energy-saving mode: Short press the power button to turn on; long press for 2 seconds to turn off. Short press to enter energy-saving mode. Setting operation mode: In the on state, short press the M button to switch between heating, cooling, and ventilation modes. Setting room temperature and fan speed: Use < to lower and > to raise the set temperature. The display shows SET when adjusting. Fan speed settings include off, low, high, and automatic modes, selected by short pressing the fan speed button. Default setting: The fan automatically turns off when the room temperature reaches the set temperature. Setting time and timer for power on/off: Long press the timer button for 3 seconds to adjust hours and minutes.
  • Page 18: Installation guide for GreenCon RC-T2/T4 includes instructions for setting the week, timer functions, and keyboard lock. To set the week, press the designated button until week flashes, then adjust using the arrow keys. After completing the settings, short press the button to enter the timer settings or exit by pressing any key. For timer settings, ON will flash for setting the start time, followed by confirmation of hours and minutes. OFF will flash for setting the shutdown time, with similar confirmation steps for hours and minutes. Setting minutes or hours to -- indicates that the time is invalid. The keyboard lock can be activated by holding the M key and pressing the arrow key within six seconds. To reset the device, hold the M key and the arrow keys for ten seconds while powered off. The automatic switching function between heating and cooling modes is controlled by the thermostat based on room temperature. The heating mode will stop the fan when activated.
  • Page 19: Installation guide for GreenCon RC-T2/T4. In heating mode, the fan does not operate if this function is enabled, and fan speed cannot be changed. Time programming allows the system to automatically adjust the set temperature based on pre-set times. The programming divides the week into two parts: weekdays and weekends, with four time slots for each part. Default settings include start times and heating/cooling temperatures for each time slot. Weekday programming requires holding the button for 5 seconds to access the settings. Settings include adjusting the start time, heating temperature, and cooling temperature for each time slot. After programming weekdays, the interface will display weekend settings, which follow the same operation method. The system includes a timed shutdown feature indicated by a flashing OFF.
  • Page 20: Installation guide for GreenCon RC-T2/T4. Long press M for 6 seconds to enter parameter setting mode. Short press M to select the parameter item to be set. Press < and > to adjust the value of the parameter. Parameter table is shown below. Danfoss Heating Solutions.
  • Page 21: Installation guide for GreenCon RC-T2/T4 includes function definitions and settings. The device features manual mode and a 5+2 day programmable mode. There is a timed power on/off function that can be enabled or disabled. The maximum room temperature limit is adjustable between 5-35℃, with a default of 30℃. The minimum room temperature limit is also adjustable between 5-35℃. Frost protection can be turned on or off, with a set temperature range of 5-17℃. Default heating and cooling temperature settings are provided. Energy-saving mode temperature settings are included for both heating and cooling. DA/DB settings determine fan operation upon reaching the set temperature. The document is associated with Danfoss Heating Solutions.
  • Page 22: Installation guide for GreenCon RC-T2/T4. Function definitions and settings are provided. Clock display options include 24-hour and 12-hour formats. Temperature display status after shutdown can either show or not show the current temperature. User settings can be saved with options to enable or disable. Automatic switching between heating and cooling modes can be turned on or off. Deadband settings for normal mode range from 0.5℃ to 5℃. Deadband settings for ECO mode range from 5℃ to 10℃. The fan can be set to stop during heating without affecting performance. Restoration of state after power loss can either return to the previous state or shut down.
  • Page 23: Installation guide for GreenCon RC-T2/T4.
  • Page 24: Installation guide for GreenCon RC-T2/T4. Heating and cooling specifications include 85-250Vac, 50/60Hz. Details on 4 pipes with 2 wired valve applications. Information on fan settings for different applications. Details on 2 pipes with 2 wired valve applications. Reference to Danfoss heating solutions. Figures illustrating installation components. Specifications for voltage and frequency. Application settings for medium and low fan speeds. General installation instructions.
  • Page 25: Installation guide Description of hazardous substances and content Hazardous substances Part name Chromium VI compounds Lead Mercury Cadmium Polybrominated biphenyls Diphenyl ethers This table is prepared in accordance with the provisions of SJ/T 11364. O: Indicates that said hazardous substance contained in all of the homogeneous materials for this part is below the limit requirement of GB/T 26572. X: Indicates that said hazardous substance contained in at least one of the homogeneous materials used for this part is above the limit requirement of GB/T 26572.
  • Page 26: Installation guide for GreenCon RC-T2/T4. Danfoss Heating Solutions.
  • Page 27: Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved. Produced by Danfoss Heating Segment. 01/2019.