CONFIGURATION MENU  
6) Select filter replacement run time – The thermostat will 13 & 14) Keypad Lockout – This menu selection will display  
display FLTR after a set time of operation. This is a remind-  
er to change or clean your air filter. This time can be set from  
0 to 1950 hours in 50 hour increments. A selection of 000  
will cancel this feature. When “FLTR” is displayed, you  
can clear it by pressing SYSTEM. This resets the timer and  
starts counting the hours until the next filter change. Contact  
your system manufacturer for a specific replacement/main  
tenance interval.  
lock icon ( ) and “OFF” (default, keypad not locked out).  
The and are used to toggle the selection between OFF  
and ON (keypad locked out). When the keypad lockout  
selection is enabled (ON), and the SYSTEM button is  
pressed again, the display will indicate the number “0”  
(default, still disabled) in the time digits. The  
and  
are  
used to set the combination number from 0 to 999. If a  
combination of 0 is selected and the SYSTEM button is  
pressed, the menu will be exited and keypad will not be  
locked. If 1 to 999 is selected and the SYSTEM button is  
pressed, the combination is stored into memory and the  
menu is exited. The ( ) will display designating keypad  
locked with a valid combination. The SYSTEM button will  
operate for 10 seconds after the menu mode is exited to  
allow the user to change the mode from OFF to the desired  
SYSTEM mode.  
7) Select Temperature Display Adjustment 4 LO to 4 HI –  
Allows you to adjust the room temperature display up to 4°  
higher or lower. Your thermostat was accurately calibrated  
at the factory but you have the option to change the display  
temperature to match your previous thermostat. The cur-  
rent or adjusted room temperature will be displayed on the  
left side of the display.  
8) Select F° or C° Readout – Changes the display readout  
to Centigrade or Fahrenheit as required.  
While the keypad is locked out, a simultaneous press of  
and will enter the configuration menu from any  
mode instead of only OFF mode. When the menu is  
entered with the keypad lockout feature enabled, the first  
9) Selected Auto mode – This control will feature AUTO  
changeover mode when AU on is selected (default). Press  
the  
the auto changeover mode (OFF).  
or  
keys (not available on earlier models) to defeat  
menu item displayed is the combination code 0. The  
or  
keys are used to set the combination unlock number  
from 0 to 999. If the unlock number matches exactly with  
the combination lock number stored in memory when the  
SYSTEM button is pressed, the keypad is unlocked and  
the ( ) is removed. If the unlock number does not match  
when the SYSTEM button is pressed, the menu is exited  
and the keypad remains disabled.  
10)Limited Heat Range – This feature provides a maximum  
setpoint temperature for heat. The default setting is 90°F. It  
can be changed between 62°F and 89°F by pressing the  
or  
key.  
11)Limited Cool Range – This feature provides a minimum  
setpoint temperature for cool. The default setting is 45°F. It  
can be changed between 46°F and 82°F by pressing the  
To reset the combination code and unlock the keypad if  
the code is forgotten, see troubleshooting section.  
or  
key.  
12)This Feature Not Available.  
SPECIFICATIONS  
THERMAL DATA  
ELECTRICAL DATA  
Electrical Rating:  
Setpoint Temperature Range:  
45°F to 90°F (7°C to 32°C)  
Operating Ambient Temperature Range:  
32°F to 105°F  
20 to 30 VAC 50/60 Hz or DC  
0.05 to 1.5 Amps (Load per terminal)  
2.5 Amps Maximum Total Load (All terminals combined)  
Operating Humidity Range:  
0 to 90% RH (non-condensing)  
Shipping Temperature Range:  
-40°F to 150°F  
7
GeneralDetails
NameWhite-Rodgers 1F83-277 Heating & Air Conditioning Auto Changeover Heat Pump Thermostat User Manual
MakeWHITE RODGERS
LanguageEnglish
FiletypePDF (Download)
File size0.24 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
White-Rodgers 1E78 Non Programmable Heat Only Thermostat User Manual
White-Rodgers 1E78 Non Programmable Heat Only Thermostat User Manual
White-Rodgers 1F97-1277 Big Blue Single Stage Thermostat User Manual
White-Rodgers 1F97-1277 Big Blue Single Stage Thermostat User Manual
White-Rodgers 1F56N-444 Thermostat User Manual
White-Rodgers 1F56N-444 Thermostat User Manual
White-Rodgers M30 Thermostat Instruction Manual
White-Rodgers M30 Thermostat Instruction Manual
WHITE-RODGERS 1F51N-619 Low Voltage Evaporative Cooler Thermostat Instruction Manual
WHITE-RODGERS 1F51N-619 Low Voltage Evaporative Cooler Thermostat Instruction Manual
WHITE-RODGERS 1F86-0471 Blue Single 1 1 Stage Thermostat Instruction Manual
WHITE-RODGERS 1F86-0471 Blue Single 1 1 Stage Thermostat Instruction Manual
WHITE-RODGERS 1F90-71 5-Day 2-Day Electronic Digital Thermostat Instruction Manual
WHITE-RODGERS 1F90-71 5-Day 2-Day Electronic Digital Thermostat Instruction Manual
WHITE-RODGERS 1F95-1277 Universal Thermostat Owner’s Manual
WHITE-RODGERS 1F95-1277 Universal Thermostat Owner’s Manual
White Rodgers 1F78-151 Non Programmable Thermostat Instructions
White Rodgers 1F78-151 Non Programmable Thermostat Instructions
WHITE RODGERS 1F80-51 Programmable Electronic Digital Thermostat Instruction Manual
WHITE RODGERS 1F80-51 Programmable Electronic Digital Thermostat Instruction Manual

White-Rodgers 1F83-277 Heating & Air Conditioning Auto Changeover Heat Pump Thermostat User Manual