Home > GLOBAL > GLOBAL CEG Series Convector with Thermostat Instruction Manual

GLOBAL CEG Series Convector with Thermostat Instruction Manual

OPERATING  
MAINTENANCE  
INSTRUCTIONS  
INSTALLATION  
INSTRUCTIONS  
INSTRUCTIONS  
-
-
-
The heater must be properly installed before it is used.  
Turn the power on at the circuit breaker panel.  
Electronic thermostat: Set the thermostat temperature at the  
wanted room temperature  
1- Once a year, remove the front panel and use a vacuum cleaner  
to remove the dust accumulation inside the heater and through  
openings of the front panel.  
CAUTION: Use supply wires suitable for 90 °C (194 °F).  
- For bathroom use, the heater must be installed so that  
switches and other controls cannot be touched by anyone  
in the bath or shower.  
INSTALLATION INSTRUCTIONS  
Convector “CEG” Series  
2- Cleaning should be done while the heater is disconnected from  
the main service panel. Wait until the housing and heating  
element cool before performing maintenance.  
3- Replace the front panel before energizing.  
4- Any other servicing should be performed by a qualified  
technician.  
CONTROL:  
SURFACE WALL MOUNTING;  
1- Locate approximately the power supply leads behind the  
planned location of the heater. Recommended clearance  
below heater base to floor is 4 in. (102 mm) minimum.  
Allow 4 in. (102 mm) minimum clearance between sides  
of heater and any adjacent walls. The leads shall be at the  
right of the wall bracket.  
Model with built-in electronic thermostat:  
The electronic thermostat shall keep the room temperature in a range  
of ± 1 °C (± 2 °F) unless the room is not well insulated or the heater  
is too or not enough powerful for the room.  
WARNING  
When using electrical appliances, basic precautions should always be taken  
to reduce the risk of fire, electrical shock and injury, including the following.  
WARRANTY  
Model without control:  
2- Lean the bottom of the wall bracket on the floor and mark  
with a pencil the height desired (of the heater bottom)  
using the wholes with inches written on the side.  
3- Secure wall bracket with the 4 screws supplied. The bottom  
of the key holes shall be in line with the previous marks.  
Triangle mark on horizontal bar is the center of the heater.  
Before installing wall support, align center of heater with  
support center mark and make sure the heater sides are at  
least 4 in. (102 mm) from any adjacent walls.  
Maintain room temperature by a line-voltage wall thermostat  
approved for residential heating. Even if it is not mandatory, an  
electronic thermostat gives better performance than a conventional  
thermostat.  
Read carefully these instructions before installation, operation of the  
heater. Failure to adhere to the instructions could result in fire, electric  
shock, serious personal injury, and death or property damage. Review  
frequently for continuing safe operation and instruction of future users,  
if necessary.  
IMPORTANT  
1- Read all instructions before installing or using this heater.  
2- This heater is hot when in use. To avoid burns, do not let bare skin  
touch hot surfaces. Keep combustible materials, like furniture, pillows,  
bedding, papers, clothes, and curtains at least 36 in. (915 mm) from the  
front of the heater and away from the sides.  
3- Extreme caution is necessary when any heater is used by or near  
children or invalids and whenever the heater is left operating and  
unattended.  
4- Do not operate any heater after it malfunctions. Disconnect power  
at service panel and have heater inspected by a reputable electrician  
before reusing.  
4- Untighten wire holder (for Loomex cable) and make  
electrical connections by having the heater the nearest  
possible to the electrical wire. For BX cable, remove one of  
the two knock-outs, install a connector (not furnished) and  
have 6 to 8 in. (15 to 20 cm) of free wire and get them out  
of the hole of the wire holder in order to make connections  
from outside. Do not forget to connect the green wire to  
ground wire in order to have a safe grounded heater.  
5- Once connections completed, place bottom T slots in the  
base part of support, and clip the upper side of the body in  
the upper U shape part of the support.  
TOP  
HAUT  
TOP  
HAUT  
Wiring Diagram:  
1
2
INSTRUCTIONS  
L1  
L2  
THERMOSTAT  
Model with built-in  
L1 Load 1 Load 2 L2  
electronic thermostat  
8
7
6
5
4
8
7
6
5
4
American version only  
up to 240V  
Mark  
the height  
desired  
6- Do not let the excess of the supply wire come in contact  
with the back of the heater, as well as any other object.  
7- Put the main power on.  
5- Do not use outdoors.  
6- To disconnect heater, turn off power to heater circuit at main disconnect  
panel.  
Wiring Diagram:  
Model without control  
CENTRE  
CAUTION:  
HAUT - TOP  
L1  
High temperature, risk of fire, keep electrical cords, drapery,  
furnishings, and other combustibles at least 36 in. (915 mm)  
from the front of the heater and away from the sides. To reduce  
the risk of fire, do not store or use gasoline or other flammable  
vapors and liquids in the vicinity of the heater.  
DETAIL A  
7- Do not insert or allow foreign objects to enter any exhaust opening as  
this may cause an electric shock or fire, or damage the heater.  
8- Do not block air intakes or exhaust in any way whatsoever.  
9- This heater has hot and arcing or sparking parts inside. Do not use it in  
areas where gasoline, paint, or flammable liquids are used or stored.  
10-Use this heater only as described in this manual. Any other use not  
recommended by the manufacturer may cause fire, electric shock, or  
injury.  
11-AMERICAN VERSION ONLY: Some models (up to 240V) include  
a visual alarm to warn that parts of the heater are getting excessively  
hot. If the light turns on, immediately turn the heater off and inspect  
for any objects on or adjacent to the heater that may have blocked  
the airflow or otherwise caused high temperatures to have occured.  
If no obstruction is visible, the heater must be checked by a quali-  
fied person. DO NOT OPERATE THE HEATER WHEN THE  
ALARM LIGHT IS ON.  
American version only  
up to 240V  
L2/N  
Center mark  
3
IMPORTANT  
Do not obstruct the front of the heater  
for at least 48 in. (1200 mm).  
OPTIONS:  
All heating equipment and options must be installed in  
accordance with local and national codes.  
Built-in relay:  
4
5
8
8
7
6
5
4
7
6
5
4
A
- Refer to the diagram included with the relay option for  
connections.  
- Refer to instructions supplied with the option for mounting.  
12-The thermostat should not be considered an infallible device in cases  
where maintaining a temperature is considered critical. Examples:  
Hazardous material storage, computer server room, etc. In these  
particular cases, it is imperative to add a monitoring system to avoid  
the consequences of a thermostat failure.  
4’’  
(102 mm)  
minimum  
4’’  
(102 mm)  
minimum  
4’’ (102 mm)  
minimum  
INS420-201402-03  
SAVE THESE INSTRUCTIONS  
GeneralDetails
NameGLOBAL CEG Series Convector with Thermostat Instruction Manual
MakeGLOBAL
LanguageEnglish
FiletypePDF (Download)
File size0.27 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
GLOBAL WIFI Digital Heating Thermostat User Manual
GLOBAL WIFI Digital Heating Thermostat User Manual
GLOBAL WiFi Heating Thermostat User Manual
GLOBAL WiFi Heating Thermostat User Manual
GLOBAL HY09RF WIFI Wireless Thermostat User Manual
GLOBAL HY09RF WIFI Wireless Thermostat User Manual
GLOBAL Touch Screen Thermostat HY08AC User Manual
GLOBAL Touch Screen Thermostat HY08AC User Manual
GLOBAL Digital Heating Thermostat User Manual
GLOBAL Digital Heating Thermostat User Manual
GLOBAL HY06RF-BW/WW/WE Thermostat User Manual
GLOBAL HY06RF-BW/WW/WE Thermostat User Manual

GLOBAL CEG Series Convector with Thermostat Instruction Manual
Get the free PDF manual for the GLOBAL CEG Series Convector with Thermostat Instruction Manual and access setup steps, usage instructions, and troubleshooting tips. 👉 View online or download now to keep your thermostat running smoothly!

GLOBAL CEG Series Convector with Thermostat Instruction Manual Overview

Summary of Contents

  • Page 1: The heater must be properly installed before it is used. Turn the power on at the circuit breaker panel. Set the thermostat temperature at the wanted room temperature. Remove the front panel and use a vacuum cleaner to remove dust accumulation inside the heater once a year. Use supply wires suitable for 90 °C (194 °F). For bathroom use, the heater must be installed so that switches and other controls cannot be touched by anyone in the bath or shower. Cleaning should be done while the heater is disconnected from the main service panel. Do not operate any heater after it malfunctions. Extreme caution is necessary when any heater is used by or near children or invalids. Do not block air intakes or exhaust in any way whatsoever.