Honeywell RLV450 Programmable Thermostat
RLV450
PROGRAMMABLE THERMOSTAT
USER GUIDE
READ BEFORE INSTALLING
DESCRIPTION
INSTALLATION
Temperature pre-
set buttons
WARNING
TURN OFF POWER TO THE HEATING SYSTEM AT THE MAIN
POWER PANEL TO AVOID ELECTRICAL SHOCK. THE
INSTALLATION MUST BE PERFORMED BY AN ELECTRICIAN.
All cables and connections must conform to the local electrical
code.
Indicates that the tem-
perature setpoint is dis-
played
Indicates that the set-
tings are locked
Time and day
Special CO/ALR solderless connectors must be used when
connecting with aluminum conductors.
Install the thermostat onto an electrical box.
Install the thermostat about 5 feet high, on an inside wall facing the
heater.
Avoid locations where there are air drafts (such as the top of a
staircase or an air outlet), dead air spots (such as behind a door),
or direct sunlight.
Do not install the thermostat on a wall that conceals chimney or
stove pipes.
Set the hour
Set the minute
Temperature
Indicates the current
mode of operation
Set the day
Program the schedule
Temperature pre-
set icon
Skip a period
Indicates that the
thermostat is configured
for a fan-forced heater
Select the mode of
operation
Indicates the
heating power
The thermostat wires are not polarized; either wire can be
connected to the load or to the power supply.
Indicates the current
period (appears in auto-
matic mode only)
Temperature
adjustment but-
tons
NOTE:
Always keep the thermostat's vents clean and unobstructed.
Indicates that the thermostat
is without power *
1.
* LP appears only for the first two minutes when the thermostat is without
power. This can occur during a power outage or when the thermal protection
device inside the baseboard heater is opened.
Fig. 1.
This programmable thermostat can be used to control an electric heating
system such as an electric baseboard heater, a radiant ceiling, a radiant floor,
a convector or a fan-forced heater.
The thermostat cannot be used with:
•
•
•
•
a resistive load over 16.7 A
a resistive load under 2 A
a system driven by a contactor or relay (inductive load)
a central heating system
M38000
SUPPLIED PARTS:
•
•
•
One (1) thermostat
Two (2) 6-32 screws
Two (2) solderless connectors
Fig. 2.
69-2201ES-08
| General | Details |
|---|---|
| Name | Honeywell RLV450 Programmable Thermostat |
| Make | Honeywell |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.56 MB |

Honeywell T6 Pro Programmable Thermostat User Manual

Honeywell D1-528 Direct Thermostat Installation Guide

Honeywell FocusPRO P200 Programmable Thermostat User Guide

Honeywell RCHT8610WF Series Smart Thermostat Installation Guide

Honeywell T9 Smart Thermostat Installation Guide

Honeywell TH2320WF4011 FocusPRO Smart S200 Series Thermostat User Guide

Honeywell TL116A Thermostat Installation Guide

T10 Pro Smart Thermostat with Redlink Room Sensor

Honeywell TH6320WF2003 Lyric T6 Pro Wi-Fi Programmable Thermostat User Guide

Honeywell RTH9580 Wi-Fi Color Touchscreen Programmable Thermostat User Guide

Honeywell RLV450 Programmable Thermostat Overview
Summary of Contents
- Page 1: Programmable thermostat user guide Read before installing Installation must be performed by an electrician. All cables and connections must conform to the local electrical code. Install the thermostat about 5 feet high, on an inside wall facing the heater. Avoid locations with air drafts, dead air spots, or direct sunlight. The thermostat wires are not polarized; either wire can be connected to the load or to the power supply. Always keep the thermostat's vents clean and unobstructed. This programmable thermostat can control various electric heating systems. The thermostat cannot be used with certain resistive loads or central heating systems. Supplied parts include one thermostat, screws, and solderless connectors.
- Page 2: Connect the thermostat wires to the line wires and to the load wires using solderless connectors for copper wires. Early Start can be used in Automatic mode only. When this function is enabled, the thermostat calculates the optimal time to start heating. Select 15-second cycles in most cases as it provides better temperature control. The settings are locked. The temperature adjustment buttons only allow you to view the temperature setpoint. The thermostat can automatically re-adjust its clock at Daylight Savings Time changeover. The function is disabled (default setting) when the clock loses its setting. The configuration switches are on the back of the thermostat. The thermostat normally displays the actual temperature. To view the setpoint, press the V or W button briefly. To change the setpoint, press the V or W button until the desired temperature is displayed. Return power to heating system.
- Page 3: Using a preset temperature The thermostat has 3 preset temperatures: Comfort temperature, Economy temperature, Vacation temperature. The Comfort temperature is used in periods 1 and 3, and the Economy temperature is used in periods 2 and 4. You can have a different program for each day of the week. To use the Comfort or Economy temperature, press the corresponding button. To store the Comfort or Economy temperature, press and hold the appropriate button for approximately 3 seconds. To modify the schedule, press Pgm to access the programming mode. Automatic mode sets the temperature according to the programmed schedule. During a power outage, settings are stored in memory. Manual mode requires the temperature to be set manually. The schedule consists of 4 periods per day which represents a typical weekday.
- Page 4: Solutions The product should not be disposed of with other household waste. Check for the nearest authorized collection centers or authorized recyclers. The correct disposal of end-of-life equipment will help prevent negative consequences for the environment and human health. Resideo warrants this product, excluding battery, to be free from defects in workmanship or materials, under normal use and service, for a period of one year from the date of first purchase by the original purchaser. If the product is defective, return it with a bill of sale or other dated proof of purchase. This warranty does not cover removal or reinstallation costs. Resideo’s sole responsibility shall be to repair or replace the product within the terms stated above. This warranty gives you specific legal rights, and you may have other rights which vary from state to state. If you have any questions about the operation of your thermostat, please contact customer assistance. Approval: CSA / UL
- Page 5: Termostato programable Guía del usuario Leer antes de instalar Descripción Instalación Advertencia Cortar la alimentación del sistema de calefacción en el panel de alimentación principal para evitar riesgos de electrocución. Todos los cables y conexiones deben ser conformes con el código de electricidad local. El termostato debe instalarse a alrededor de 1,5 m (5 pies) del piso, en una pared interior frente al aparato de calefacción. El termostato no debe utilizarse en condiciones donde la carga resistiva es mayor que 16,7 A o menor que 2 A.
- Page 6: Conectar los cables del termostato a la alimentación y a la carga por medio de conectores sin soldadura para cables de cobre. El encendido anticipado puede usarse en modo automático solamente. Cuando esta función está activada, el termostato calcula el momento óptimo de encendido de la calefacción para obtener la temperatura deseada a la hora establecida. En la mayoría de los casos se deben seleccionar ciclos de 15 segundos, porque permiten un mejor control de la temperatura. Los ajustes están bloqueados. Los botones de ajuste de la temperatura sólo permiten ver el punto de ajuste de la temperatura. El termostato puede reajustar la hora automáticamente cuando hay que hacer el cambio a la hora de verano. Esta función está desactivada por defecto cuando se pierde el ajuste de la hora. Los conmutadores de configuración están en la parte posterior del termostato. El termostato indica normalmente la temperatura del momento. Para ver el punto de ajuste, presionar los botones brevemente.
- Page 7: Uso de la temperatura predefinida. La temperatura de Confort se usa en los períodos 1 y 3 y la temperatura de Economía en los períodos 2 y 4. El termostato tiene 3 temperaturas predefinidas: Temperatura de Confort, Temperatura de Economía, Temperatura de Vacaciones. Se puede tener un programa diferente para cada día de la semana. Para usar la temperatura Confort o Economía, presionar el botón correspondiente. Para modificar el horario, presionar Pgm para acceder al modo de programación. En caso de corte de corriente, los ajustes están salvaguardados en la memoria. El termostato volverá al modo de funcionamiento que estaba activo antes del corte de electricidad. El horario consiste en 4 períodos por día, que representan un día de semana típico. Verificar si el termostato está en Modo Automático para asegurar que la temperatura cambie según el horario programado.
- Page 8: Instromet Mexicana S. de R.L. de C.V. garantiza que este producto está libre de defectos en su mano de obra y materiales por un término de 1 año a partir de la fecha de la compra. Si se determina que el producto está defectuoso, Instromet deberá reparar o reemplazar el producto bajo ciertas condiciones. El sistema de calefacción tiene una carga menor que la carga mínima requerida. El rendimiento del termostato es reducido debido a un error del sensor. La única responsabilidad de Instromet será reparar o reemplazar el producto dentro de los términos establecidos. Esta garantía es la única garantía expresa que Instromet ofrece respecto de este producto. La duración de cualquier garantía implícita se limita a la duración de un año de esta garantía. Esta garantía no es válida si el producto ha sido utilizado en condiciones distintas a las normales. El aparato digital de clase B cumple con la normativa canadiense ICES-003. Si este producto está reemplazando a un equipo de control existente que contiene mercurio, no lo coloque en la basura.