Home > WHITE RODGERS > WHITE-RODGERS 1F86EZ-0251 Emerson Blue Easy Set Thermostat User Manual
WHITE-RODGERS 1F86EZ-0251 Emerson Blue Easy Set Thermostat User Manual
Installation
Select Configuration Options
The configuration menu allows you to set certain thermostat operating characteristics to your system or personal requirements.
Enter Menu
Menu Navigation
SYSTEM
Press
and hold
for 3 seconds
ome
Press
for next. Press
to go back
Configuration Menu
Menu Screen
Number
Displayed
(Factory Default)
Press or
to select options
01
(SS)
HP
Select Single Stage (SS) or
Heat Pump (HP) for a single compressor
02
03
04
05
06
Sleep
(OFF)
On
1 to 12
On
Select Sleep Timer On or OFF
If selected OFF, skip to menu screen 04
h
(8)
Select 1 to 12 hours for Sleep Timer On.
See Sleep Timer section on page 3
CS
(OFF)
Select Cool Savings Feature On or OFF
If selected OFF, skip to menu screen 06
CS
(3)
1 to 6
FA, SL
Select 1 to 6 for Cool Savings Feature On
See Cool Savings section on page 3
Select Adjustable Anticipation, cycle rate for Heat
See table below
CR
(ME)
07
08
FA, SL
On
Select Adjustable Anticipation, cycle rate for Cool
See table below
CR
(ME)
CL
(OFF)
Select Compressor Lockout OFF or On. When selected On,
the thermostat will wait 5 minutes before turning the
compressor on.
09
L
(On)
OFF
Select Display Light On of OFF. When selected On and the “C”
terminal is connected, the backlight will stay on continuously.
When OFF the backlight will come on for a short time when any
key is pressed.
10
11
12
13
Room Temp
(0)
4 LO to
4 HI
Select room temperature display for 4o higher or 4o lower than
the actual temperature
oF
oC
Select oF or oC Display (temperature displayed in Fahrenheit or
Celsius)
Change Filter
(OFF)
On
Select filter maintenance indicator OFF or On.
If selected OFF, item B will be skipped
Change Filter
(200 h)
25 to 1975
Select 25 to 1975 hours for Change Filter reminder
See Change Filter reminder section on page 3
To exit the menu: Set the system switch to Cool or Heat. If
no keys are pressed within fifteen minutes, the thermostat will
revert to normal operation.
Select Cycle Rate – The cycle rate can be adjusted to keep
the heat or cool on longer or shorter to match the temperature
response of the home with your heating and cooling system.
MODE
Fast
(FA)
Medium
(ME)
Slow
(SL)
SS Heat
0.6oF
1.2oF
1.2oF
0.8oF
1.2oF
1.7oF
1.7oF
SS Cool
HP Heat & Cool
5
| General | Details |
|---|---|
| Name | WHITE-RODGERS 1F86EZ-0251 Emerson Blue Easy Set Thermostat User Manual |
| Make | WHITE RODGERS |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.36 MB |

White-Rodgers 1E78 Non Programmable Heat Only Thermostat User Manual

White-Rodgers 1F97-1277 Big Blue Single Stage Thermostat User Manual

White-Rodgers 1F56N-444 Thermostat User Manual

White-Rodgers 1F83-277 Heating & Air Conditioning Auto Changeover Heat Pump Thermostat User Manual

White-Rodgers M30 Thermostat Instruction Manual

WHITE-RODGERS 1F51N-619 Low Voltage Evaporative Cooler Thermostat Instruction Manual

White Rodgers 1F78-151 Non Programmable Thermostat Instructions

WHITE RODGERS 1F80-51 Programmable Electronic Digital Thermostat Instruction Manual

WHITE-RODGERS 1F86-0471 Blue Single 1 1 Stage Thermostat Instruction Manual

WHITE-RODGERS 1F90-71 5-Day 2-Day Electronic Digital Thermostat Instruction Manual