Home > WHITE RODGERS > WHITE-RODGERS 1F86EZ-0251 Emerson Blue Easy Set Thermostat User Manual

WHITE-RODGERS 1F86EZ-0251 Emerson Blue Easy Set Thermostat User Manual

Troubleshooting  
Reset Operation  
for approximately 10 seconds until the display goes blank. If  
the thermostat has power, has been reset and still does not  
function correctly contact your heating/cooling service person  
or place of purchase.  
If a voltage spike or static discharge blanks out the display  
or causes erratic thermostat operation, you may need to  
reset the thermostat. To reset, the System Switch must be  
in Cool or Heat. Simultaneously press  
and  
buttons  
Symptom  
Possible Cause  
Corrective Action  
No Heat/No Cool/No Fan  
common problems)  
1. Blown fuse or tripped circuit breaker.  
2. Furnace power switch to OFF.  
1. Replace fuse or reset breaker.  
2. Turn switch to ON.  
3. Furnace blower compartment door or  
panel loose or not properly installed.  
3. Replace door panel in proper position to engage safety  
interlock or door switch.  
No Heat  
1. System Switch not set to Heat.  
1. Set System Switch to Heat and raise setpoint above  
room temperature.  
2. Loose connection to thermostat or  
system  
2. Verify thermostat and system wires are securely  
attached.  
3. Heating System requires service or  
thermostat requires replacement.  
3. Diagnostic: Set System Switch to Heat and raise  
the setpoint above room temperature. Within a five  
minutes the thermostat should make a soft click  
sound. This sound usually indicates the thermostat  
is operating properly. If the thermostat does not click,  
try the reset operation listed above. If the thermostat  
does not click after being reset contact your heating  
and cooling service person or place of purchase for  
a replacement. If the thermostat clicks, contact the  
furnace manufacturer or a service person to verify the  
heating system is operating correctly.  
No Cool  
1. System Switch not set to Cool.  
1. Set System Switch to Cool and lower setpoint below  
room temperature.  
2. Loose connection to thermostat or  
system.  
2. Verify thermostat and system wires are securely  
attached.  
3. Cooling System requires service or  
thermostat requires replacement  
3. Same procedures as diagnostic for No Heat condition  
except set the thermostat to Cool and lower the  
setpoint below the room temperature. There may be up  
to a five minute delay before the thermostat clicks in  
Cooling if the compressor lock-out option is selected in  
the configuration menu (Item 6).  
Heat, Cool or Fan Runs  
Constantly  
1. Possible short in wiring.  
2. Possible short in thermostat.  
3. Possible short in Heat/Cool/Fan  
system.  
Check each wire connection to verify they are not  
shorted or touching together. No bare wire should  
stick out from under terminal screws. Try resetting the  
thermostat as described above. If the condition persists,  
the manufacturer of your system or service person  
can instruct you on how to test the Heat/Cool/ system  
for correct operation. If the system operates correctly,  
replace the thermostat.  
4. Fan Switch set to Fan On.  
Furnace Cycles Too Fast 1. The location of the thermostat and/or  
Item 4 (CR Heat) or 5 (CR Cool) in the Configuration  
Menu is the adjustment that controls the cycle rate. If an  
acceptable cycle rate is not achieved using the FA (Fast)  
or SL (Slow) adjustment contact a local service person  
for additional suggestions.  
or Too Slow / Cooling  
Cycles Too Fast or Too  
Slow (narrow or wide  
temperature swing)  
the size of the Heating or Cooling  
System may be influencing the cycle  
rate.  
Thermostat Setting and  
Thermometer Disagree  
1. Thermostat thermometer setting  
requires adjustment.  
The thermometer can be adjusted +/- degrees as listed in  
item 8 of the Configuration Menu (see page 5). No other  
adjustment is possible.  
Blank Display and/or  
Keypad Not Responding  
1. Voltage Spike or Static Discharge.  
If a voltage spike or static discharge occurs use the Reset  
Operation listed above.  
6
GeneralDetails
NameWHITE-RODGERS 1F86EZ-0251 Emerson Blue Easy Set Thermostat User Manual
MakeWHITE RODGERS
LanguageEnglish
FiletypePDF (Download)
File size0.36 MB
Download PDF
1 Star2 Stars3 Stars4 Stars5 Stars (1 votes, average: 5.00 out of 5)
Loading...
White-Rodgers 1E78 Non Programmable Heat Only Thermostat User Manual
White-Rodgers 1E78 Non Programmable Heat Only Thermostat User Manual
White-Rodgers 1F97-1277 Big Blue Single Stage Thermostat User Manual
White-Rodgers 1F97-1277 Big Blue Single Stage Thermostat User Manual
White-Rodgers 1F56N-444 Thermostat User Manual
White-Rodgers 1F56N-444 Thermostat User Manual
White-Rodgers 1F83-277 Heating & Air Conditioning Auto Changeover Heat Pump Thermostat User Manual
White-Rodgers 1F83-277 Heating & Air Conditioning Auto Changeover Heat Pump Thermostat User Manual
White-Rodgers M30 Thermostat Instruction Manual
White-Rodgers M30 Thermostat Instruction Manual
WHITE-RODGERS 1F51N-619 Low Voltage Evaporative Cooler Thermostat Instruction Manual
WHITE-RODGERS 1F51N-619 Low Voltage Evaporative Cooler Thermostat Instruction Manual
White Rodgers 1F78-151 Non Programmable Thermostat Instructions
White Rodgers 1F78-151 Non Programmable Thermostat Instructions
WHITE RODGERS 1F80-51 Programmable Electronic Digital Thermostat Instruction Manual
WHITE RODGERS 1F80-51 Programmable Electronic Digital Thermostat Instruction Manual
WHITE-RODGERS 1F86-0471 Blue Single 1 1 Stage Thermostat Instruction Manual
WHITE-RODGERS 1F86-0471 Blue Single 1 1 Stage Thermostat Instruction Manual
WHITE-RODGERS 1F90-71 5-Day 2-Day Electronic Digital Thermostat Instruction Manual
WHITE-RODGERS 1F90-71 5-Day 2-Day Electronic Digital Thermostat Instruction Manual

WHITE-RODGERS 1F86EZ-0251 Emerson Blue Easy Set Thermostat User Manual