DEVI 610 Electronic Thermostat Installation Guide
| General | Details |
|---|---|
| Name | DEVI 610 Electronic Thermostat Installation Guide |
| Make | DEVI |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.67 MB |

DEVI 140F1143 Electronic Intelligent Timer Thermostat Installation Guide

DEVIreg Electronic Intelligent Timer Thermostat Installation Guide

DEVI 330 Electronic Thermostat Installation Guide

DEVI 532 Electronic Thermostat Installation Guide

DEVI 140F1161 Intelligent Electronic Timer Controlled Thermostat Installation Guide

DEVIreg 130 Electronic Thermostat Installation Guide

DEVI 140F1064 Touch Electronic Intelligent Timer Thermostat Installation Guide

DEVIreg 316 Electronic Thermostat Installation Guide

DEVI 530M Electronic Thermostat Installation Guide

DEVI 316 Electronic Thermostat Installation Guide

DEVI 610 Electronic Thermostat Installation Guide Overview
Summary of Contents
- Page 1: Installation guide for DEVIreg™ 610 electronic thermostat.
- Page 2: DEVIreg™ 610 Installation guide
- Page 3: Introduction DEVIreg™ 610 is an electronic thermostat to be installed directly on the wall. It is provided with a 2-pole switch and a wire sensor to control the desired temperature. The thermostat has a button for adjusting the temperature setting with a scale from -10 °C to +50 °C, and an LED indicator that shows standby periods (green light) and heating periods (red light).
- Page 4: DEVIreg™ 610 Technical specifications Operating temperature range: -30°C to +50°C Standby power consumption: Max. 0.93W Relay specifications for resistive and inductive loads Maximum load: 10A / 2300W @ 230V Sensing units: NTC 15kOhm at 25°C Hysteresis: 0.2 °C Cable specification: max 1 x 4 mm² or 2 x 2.5 mm² Storage temperature range: -20 °C to +65 °C Protection class: Class II
- Page 5: DEVIreg™ 610 Dimensions: 100 x 69.5 x 45 mm Weight: 165 g The product complies with the EN/IEC Standard “Automatic electrical controls for household and similar use.” Safety Instructions: Make sure the mains supply to the thermostat is turned off before installation. The installation of the thermostat must be done by an authorized and qualified installer according to local regulations. The thermostat must be connected to a power supply via an all-pole disconnection switch. The sensor is to be considered as live voltage. Always connect the thermostat to continuous power supply. Do not expose the thermostat to moisture, water, dust, and excessive heat.
- Page 6: DEVIreg™ 610 Mounting instructions The thermostat can be placed both indoors and outdoors. Place the thermostat on a wall, pole, steel/wooden plate or pipe. In wet rooms, place the thermostat according to local regulation on IP classes.
- Page 7: DEVIreg™ 610 Follow the steps below to mount the thermostat. Open the thermostat: Set adjustment button to minimum temperature. Loosen the 2 screws and open the front cover. Installation Guide
- Page 8: DEVIreg™ 610 Fasten the thermostat by driving the screws through the holes in the bottom corners of the thermostat. Seal the holes with the enclosed screw stopper to maintain the density. Connect the thermostat according to the connection diagram. IP44 Mains 220-240V~ Max. Load 10 (1) A Heating: L-main, N-main, L-load, NO (normally open) - load. Cooling: L-main, N-main, L-load, NC (normally closed) - load. Installation Guide
- Page 9: DEVIreg™ 610 The screen of the heating cable must be connected to the earth conductor of the power supply cable by using a separate connector. Reinstall the front cover. Ensure that the adjustment button can be adjusted within full temperature range, i.e. from -10 °C to +50 °C. Install sensor using the supplied sensor cable - spec. NTC 15 kΩ @ 25°C. Press out the blanket located at the bottom of the thermostat and insert the seal nipple. Connect sensor to terminals 6+7. The sensor cable can be extended up to 50 m with 1,5 mm² installation cable without affecting the accuracy of the thermostat. Do not place the cable parallel to other installation cables as undesirable signals may be induced. The installation must be permanent. If the sensor is to be built in, used for pipe applications, or exposed to pressure, always install it in a conduit.
- Page 10: Warranty A 2-year product warranty is valid for thermostats: DEVIreg™ 610. Danfoss offers DEVIwarranty valid from the date of purchase under specific conditions. During the warranty period, Danfoss will offer a new comparable product or repair the product if found faulty due to defective design, materials, or workmanship. The decision to repair or replace will be solely at the discretion of Danfoss. Danfoss shall not be liable for any consequential or incidental damages. The warranty is valid only if the WARRANTY CERTIFICATE is completed correctly and proof of purchase is provided. The WARRANTY CERTIFICATE must be filled in, stamped, and signed by the authorized installer. DEVIwarranty does not cover damage caused by incorrect use or installation by non-authorized electricians. All work will be invoiced in full if Danfoss inspects or repairs faults due to incorrect conditions. The warranty explicitly excludes all claims exceeding the stated conditions.
- Page 11: Warranty certificate details the information required for the warranty. It includes the name of the individual or entity to whom the warranty is granted. The address of the warranty holder is required. The purchase date of the product must be noted. The serial number of the product is necessary for warranty validation. The specific product and its article number are to be included. Installation date and signature are required for warranty purposes. Connection date and signature may also be included. Some fields, such as connected output, are not mandatory.
- Page 12: DEVIreg™ 610 Installation guide
- Page 13: Disposal instruction Installation guide
- Page 14: DEVIreg™ 610 Installation guide
- Page 15: Page 15
- Page 16: DEVIreg™ 610 Product documentation Designed in Denmark for Danfoss A/S IP 44 10 A / 2300 W @ 230 V~ -10 to +50 °C 220-240 V~ 50-60 Hz~ For UK customer only: Importer: Danfoss Ltd.