DEVIreg™ 610
The screen of the heating cable must be connected to
the earth conductor of the power supply cable by using
a separate connector.
4.
5.
Reinstall the front cover.
Ensure that the adjustment button can be adjusted
within full temperature range, i.e. from -10 °C to
+50 °C.
6.
Install sensor using the supplied sensor cable - spec.
NTC 15 kΩ @ 25°C.
•
•
Press out the blanket located at the bottom of the
thermostat and insert the seal nipple.
Connect sensor to terminals 6+7.
The sensor cable can be extended up to 50 m with
1,5 mm² installation cable without affecting the
accuracy of the thermostat.
Do not place the cable parallel to other installation
cables as undesirable signals may be induced.
The installation must be permanent.
If the sensor is to be built in, used for pipe
applications, or exposed to pressure, always install it
in a conduit.
7.
Turn on the power supply.
Installation Guide
9
| General | Details |
|---|---|
| Name | DEVI 610 Electronic Thermostat Installation Guide |
| Make | DEVI |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.67 MB |

DEVI 140F1143 Electronic Intelligent Timer Thermostat Installation Guide

DEVIreg Electronic Intelligent Timer Thermostat Installation Guide

DEVI 330 Electronic Thermostat Installation Guide

DEVI 532 Electronic Thermostat Installation Guide

DEVI 140F1161 Intelligent Electronic Timer Controlled Thermostat Installation Guide

DEVIreg 130 Electronic Thermostat Installation Guide

DEVI 140F1064 Touch Electronic Intelligent Timer Thermostat Installation Guide

DEVIreg 316 Electronic Thermostat Installation Guide

DEVI 530M Electronic Thermostat Installation Guide

DEVI 316 Electronic Thermostat Installation Guide