VIMAR 02912 Wi-Fi Thermostat Instruction Manual
SMART CLIMA
02912 - Wi-Fi thermostat
the extremes
Electronic Wi-Fi thermostat for local control and advanced remote temperature management
via View App, heating and air conditioning in ON/OFF and PID mode, class I temperature
control device (contribution 1%) in ON/OFF mode, class IV (contribution 2%) in PID mode,
configuration via View App on standard Bluetooth technology, 1 digital input, 1 relay output
5(2) A 240 V~, power supply 100-240 V~ 50/60 Hz, white LED backlighting, surface mounting,
white.
• For use for Heating/Air Conditioning (winter/summer).
• Operating modes: Automatic, Manual, Reduction, Absence, Protection, Off, Timed Manual.
• Temperature control algorithms: configurable PID or ON/OFF.
• Operating temperature: T40 (0 °C ÷ +40 °C) (indoor use).
• Protection degree: IP20.
• ErP classification (EU Reg. 811/2013): - ON/OFF: class I, contribution 1%. - PID: class IV,
contribution 2%.
Download the View
App from the stores onto the tablet/smartphone you will be
• Device in class II
• Number of manual cycles: 3,000
using for configuration.
• Number of automatic cycles: 100,000
• Type of contact opening: micro-disconnection
• Type of action: 1.C
You will also need:
Amazon Alexa, Google Assistant voice assistants for possible voice operation
• Tracking index: PTI175
• Degree of pollution: 2
CONFIGURATION IN
1. Create your Administrator or Installer account on MyVimar (on-line).
• Rated pulse voltage: 4000 V
• Software class: A
2. Wire the thermostat.
• Reading resolution: 0.1 °C
3. Start the View App and log in with the credentials you just created.
4. To associate the thermostat:
• Settings resolution: 0.1 °C from App and 0.5 °C from device
• Update of temperature displayed: every 10 s
• Room temperature display: 0 °C +40 °C
• Hysteresis adjustable via App: from 0.1 °C to 1 °C
• Hourly temperature setting (via App)
• In the event of new systems, select “Create a new Smart ecosystem” and give it a name.
Select “Vimar Smart Thermostat” “Proceed”
• In the event of an existing system, select the “Smart Devices” ecosystem “+” “Vimar
Smart Thermostat” “Proceed”
• Room temperature during transportation: -25 °C +60 °C
• Clock error: ≤ 1 s per day
• Press button B for 5 s; activate the Bluetooth connection on your tablet/smartphone and
approach the thermostat
• Configuration via View App using Bluetooth technology
• Controllable via View App, Amazon Alexa and Google Assistant voice assistants.
• Dimensions: 106 x 118 x 20.5 mm.
• Select “Proceed” and set the connection to the Wi-Fi network following the instructions
provided by the wizard
• Name the thermostat and set the time zone
• Go to the “Smart Devices” section and set the thermostat parameters
OPERATION.
Using the View App, making use of the WiFi/Internet connection the following can be set:
For details please refer to the manual entitled “Programming thermostats 02912-02913”
• Time schedules (times and temperature levels T1, T2 and T3)
• Setpoint for all operating modes (Manual, Reduction, Absence, Protection). The operating
mode can be changed from the View App after one ON/OFF cycle
• Manual operation time: between 1 min and 23 hours (with 1-min steps); default = 60 min
• Lighting in standby: high, medium, low, off with default = medium
• Temperature calibration for heating: between -5°C and +5°C with default = 0°C
• Temperature calibration for air conditioning: between -5°C and +5°C with default = 0°C
• Relay output status: normally open, normally closed; default = normally open
• Control type: On/Off, PID; default = On/Off
OPERATION WITHOUT CONFIGURATION VIA APP.
If configuration is not done via the View App, the thermostat is designed to accommodate
operation in manual mode.
RESETTING THE THERMOSTAT.
The reset restores the factory settings. Within the first 5 minutes within which it is powered, press
button B for 30 s.
• Hysteresis for On/Off control: between 0.1°C and 1°C; default = 0.2°C
• Proportional band for PID control: between 0.5°C and 5°C; default = 3°C
• Integrative time for PID control: between 5 min and 120 min; default = 20 min
• Derivative time for PID control: between 0 and 255 s, disabled; default = 0
• Cycle time for PID control: between 10 min and 30 min; default = 10 min
INSTALLATION RULES.
• Installation and configuration must be carried out by qualified persons in compliance with the
current regulations regarding the installation of electrical equipment in the country where the
products are installed.
• The NO-C contact of the relay must be protected against overloads by installing a device, fuse
or automatic 1-way switch, with a rated current not exceeding 10 A.
In the event of a power outage, once the power is restored, the thermostat restarts with the
operating mode prior to the outage. If the mode set was “Automatic” the thermostat will restart
in “Manual” mode and the first time it reconnects to the Cloud, it will synchronise the time/date
again and then switch to “Automatic” mode.
• Do not connect a SELV circuit to the NO-C and IN-N terminals as there is no double insulation
with on the L-N terminals.
• The device must be installed at a height of 1.5 m above floor level, in a suitable position for the
correct detection of the room temperature, avoiding installation in recesses, behind doors and
curtains, areas affected by heat sources or subject to the flow of forced heating/cooling venti-
lation sources or affected by atmospheric factors. Avoid in particular installation on perimeter
walls or in association with devices which generate heat (e.g. dimmers or lamps).
USE.
The thermostat display shows the current temperature; when you use “
” and “
” the set
point being set during the action is displayed.
REGULATORY COMPLIANCE.
RED Directive. RoHS directive. ErP directive.
CHARACTERISTICS.
• Rated supply voltage: 100-240 V~, 50/60 Hz.
Standards EN 60730-2-7, EN IEC 60730-2-9, EN 300 328, EN 301 489-17, EN 62311, EN
IEC 63000.
• Consumption at 100 V~:
- brightness L1 (low) and relay OFF 0.3 W
Temperature control device regulation (EU) no. 811/2013.
- brightness L3 (high) and relay ON 0.85 W
Vimar SpA declares that the radio equipment complies with Directive 2014/53/EU. The full text
of the EU declaration of conformity is on the product sheet available on the following website:
• Consumption at 240 V~:
- brightness L1 (low) and relay OFF 0.5 W
- brightness L3 (high) and relay ON 1 W
REACH (EU) Regulation no. 1907/2006 – Art.33. The product may contain traces of lead.
• RF transmission power: < 100mW (20dBm).
• Frequency range: 2400-2483.5 MHz.
• Terminals:
WEEE - User information
The crossed bin symbol on the appliance or on its packaging indicates that the product at the end of its life must be collected separately
from other waste. The user must therefore hand the equipment at the end of its life cycle over to the appropriate municipal centres for the
differentiated collection of electrical and electronic waste. As an alternative to independent management, you can deliver the equipment you
want to dispose of free of charge to the distributor when purchasing a new appliance of an equivalent type. You can also deliver electronic
products to be disposed of that are smaller than 25 cm for free, with no obligation to purchase, to electronics distributors with a sales area
of at least 400 m2. Proper sorted waste collection for subsequent recycling, processing and environmentally conscious disposal of the old
equipment helps to prevent any possible negative impact on the environment and human health while promoting the practice of reusing and/
or recycling materials used in manufacture.
- 2 (L and N) for line and neutral
- 2 for digital input 120 - 240 V~ for alarm signalling (for instance boiler shutdown)
Maximum length of the 30 m contact connection cable
- 2 (NO-C) for relay output with voltage-free contact: 5(2) A 240 V~
• 2 front buttons with rocking action for control and settings.
• 1 button (positioned at the bottom) for configuration and reset.
• Side LEDs:
The Apple, iPhone and iPad logos are trademarks of Apple Inc., registered in the United States and in other Countries
and Regions. App Store is a service trademark of Apple Inc.
Google is a trademark of Google LLC.
- 2 on the left for signalling Cloud and WiFi connection
- 2 on the right for signalling ON/OFF and relay state
• White LED display for displaying temperature, set point and configuration state signalling.
• Current settable setpoint: 4 °C ÷ 40 °C.
Amazon, Alexa and all related logos are trademarks of Amazon.com, Inc. or its affiliates.
• Temp. measurement precision (integrated probe): 0.5°C between +15°C and 30°C, 0.8°C at
Viale Vicenza 14
36063 Marostica VI - Italy
02912 04 2303
| General | Details |
|---|---|
| Name | VIMAR 02912 Wi-Fi Thermostat Instruction Manual |
| Make | VIMAR |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.3 MB |

VIMAR 30810.x-02973 Smart Home View Wireless Connected Dial Thermostat Instruction Manual

VIMAR 30810.x-02973 Connected Dial Thermostat Instruction Manual

VIMAR 02952 Well-Contact Plus Electronic Touchscreen Thermostat Instruction Manual

VIMAR 02913 Surface LTE Thermostat Installation Guide

VIMAR 01910 Electronic Timer Thermostat Instruction Manual

VIMAR 02971 Smart Automation Rotary Dial Thermostat Instruction Manual

VIMAR 30810.G View Wireless Connected Dial Thermostat Instruction Manual

VIMAR 02970 Wheel Thermostat Instruction Manual

VIMAR 02912 Wi-Fi Thermostat Instruction Manual Overview
Summary of Contents
- Page 1: SMART CLIMA Electronic Wi-Fi thermostat for local control and advanced remote temperature management via View App. Operating modes include Automatic, Manual, Reduction, Absence, Protection, Off, and Timed Manual. Temperature control algorithms are configurable PID or ON/OFF. Configuration via View App using standard Bluetooth technology. Device must be installed at a height of 1.5 m above floor level for accurate temperature detection. Installation and configuration must be carried out by qualified persons in compliance with current regulations. The thermostat can operate in manual mode if not configured via the View App. The reset restores factory settings by pressing button B for 30 seconds. The product must be collected separately from other waste at the end of its life cycle. The device complies with various regulatory standards including RED, RoHS, and ErP directives.
- Page 2: Short press adjusts the set point from 4°C to 40°C in steps of 0.5°C. Long press (5 s) switches the thermostat off if on standby and switches it on if off. Green LED indicates the cloud is correctly connected, while red indicates it is not connected. Green display shows WiFi is correctly connected; red indicates WiFi is not connected. The thermostat can be in Bluetooth configuration or turned off/on. Heating is indicated by animation from the bottom up, and air conditioning by animation from the top down. A short press allows for degrees Celsius/Fahrenheit selection. A long press (5 s) enters the configuration phase, while a prolonged press (30 s) resets the thermostat. Alarms include no connection to the Wi-Fi network and no connection to the cloud. Contact for alarm signaling generates an alarm notification but does not deactivate the output relay.
- Page 3: Using a screwdriver, detach the thermostat from the bracket as shown in the figure. Make the connections and fix the bracket to the wall. Caution: Tighten the wall bracket screws, applying sufficient torque without exaggerating, in order to avoid warping it. Fix the thermostat to the bracket using the dedicated attachments shown in the figure. Types of installation.