DEVI 140F1064 Touch Electronic Intelligent Timer Thermostat Installation Guide
| General | Details |
|---|---|
| Name | DEVI 140F1064 Touch Electronic Intelligent Timer Thermostat Installation Guide |
| Make | DEVI |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.78 MB |

DEVI 140F1143 Electronic Intelligent Timer Thermostat Installation Guide

DEVIreg Electronic Intelligent Timer Thermostat Installation Guide

DEVI 330 Electronic Thermostat Installation Guide

DEVI 532 Electronic Thermostat Installation Guide

DEVI 140F1161 Intelligent Electronic Timer Controlled Thermostat Installation Guide

DEVIreg 130 Electronic Thermostat Installation Guide

DEVIreg 316 Electronic Thermostat Installation Guide

DEVI 530M Electronic Thermostat Installation Guide

DEVI 610 Electronic Thermostat Installation Guide

DEVI 316 Electronic Thermostat Installation Guide

DEVI 140F1064 Manual: Questions and Answers
DEVI 140F1064 specifications
| Power supply | 220-240 V~, 50/60 Hz |
| Maximum load | Max. 16 A / 3680 W @ 230 V |
| Floor temperature limit | 5-45°C |
| Setpoint range | Room temperature: 5-35°C |
| Sensor | NTC 6.8 kOhm at 25°C |
| Operating temperature | 0° to +30°C |
| Storage temperature | -20°C to +65°C |
| Dimensions | 85 x 85 x 20-24 mm |
| Weight | 103 g |
| Power consumption | Max. 0.40 W |
How do I set the time on my DEVI 140F1064 thermostat?
Set the time during initial setup when the unit activates for the first time.
- Press the hour numbers on the display.
- Use the < and > arrows to adjust the hour.
- Press to confirm the hour.
- Press the minutes numbers.
- Use the < and > arrows to adjust the minutes.
- Press to confirm the minutes. Installation Guide, p. 12
What's the difference between using only a floor sensor versus a combination sensor setup on the DEVI 140F1064?
Floor sensor alone controls floor temperature. Room and floor combination lets you set minimum floor temperature when using both sensors.
| Setup Type | Temperature Control |
|---|---|
| Floor sensor only | Floor temperature: 5-45°C |
| Room and floor combination | Floor temperature: 5-45°C with min. floor: 10-35°C |
Can I use the DEVI 140F1064 with a wooden floor?
Yes, but you must use a floor sensor and never set maximum floor temperature above 35°C to prevent overheating. Installation Guide, p. 7
What does the away symbol mean on the DEVI 140F1064 display?
An away period has been planned. The away temperature will be maintained 24 hours daily from departure at 00:00 until return at 00:00, when normal temperature settings resume. Installation Guide, p. 22
DEVI 140F1064 compared with other DEVI thermostats
| Specification | DEVI 140F1064 | DEVI 530M Electronic Thermostat | DEVI 532 | DEVI 316 |
|---|---|---|---|---|
| Power supply | 220-240 V~, 50/60 Hz | 220-240 V~, 50/60 Hz | 220-240 V~, 50 Hz | 220 - 240V~, 50Hz |
| Setpoint range | Room temperature: 5-35°C | 15-35°C with floor sensor only | 5-35 °C room temperature | -10 ° to +50 °C |
| Sensor | NTC 6.8 kOhm at 25°C | NTC 15 kOhm at 25°C (Default) | NTC 15 kOhm at 25 °C | NTC 15 kOhm at 25 °C |
| Operating temperature | 0° to +30°C | -10 to +30°C | -10 to +30 °C | -10 °C to +45 °C |
| Storage temperature | -20°C to +65°C | -20°C to +65°C | -20 to +65°C | -20 °C to +65 °C |
| Dimensions | 85 x 85 x 20-24 mm | 85 x 85 x 36 mm | 85 x 85 x 36 mm | 86 x 36 x 58 mm |
| Weight | 103 g | 90 g | 90 g | 180 g |
| Power consumption | Max. 0.40 W | Max. 0.25 W | Max 0.25 W | Max 0.25W |