Connection description for EASY230W / EASY230B
Connection description for EASYBATW / EASYBATB
AC 230V
AC 230V
a) Connection diagram
for gas boiler
a) Connection diagram
for gas boiler
L
L
Wired Thermostat, 230V
EASYBATW
EASYBATB
L
L
L
3V
COM
NO
COM
2 xAAA
EASY230W
EASY230B
N
NO
N
N
N
L
N
AC 230V
EASY230W / EASYBATW
EASY230B / EASYBATB
b) Connection diagram
to pump / actuator
b) Connection diagram
to pump / actuator
AC 230V
L
Quick Guide
L
EASYBATW
EASYBATB
Ver. 3
Producer:
Distributor:
COM
COM
NO
Release date: I 2024 Engo Controls S.C.
QL CONTROLS Sp z o.o. Sp. k.
43-262 Kobielice
4 Rolna St.
MAX
3(1)A
MAX
3(1)A
3V
EASY230W
Soft: v0.6
43-262 Kobielice
4 Rolna St.
Poland
2 xAAA
EASY230B
NO
Poland
N
N
N
c) Connection diagram
to the control box
c) Connection diagram
to the control box
EASYBATW
EASYBATB
EASY230W
3V
EASY230B
2 xAAA
Wired, non-programmable thermostat, battery powered (2xAAA) or 230V AC
powered. It is used for wired control of heating or cooling devices and systems. It works
by maintaining comfortable conditions in the room, in line with the setpoint
temperature set by the user. It is connected directly to a heat source or wiring centre.
For a better fit, the model is available in two colors. Safe, reliable, easy to use.
COM NO
COM NO
L
N
Product Compliance
This product complies with the following EU Directives: 2014/53/EU, 2011/65/EU
N
L
SL1
N
L
SL1
1 - 8 Zones
1 - 8 Zones
ECB08M230
ECB08M230
Technical Informations
control box
control box
N
SL1
N
SL1
Power supply
Max current
230V or 2xAAA batteries
3 (1) A
Legend:
Temperature range
Display temperature accuracy
Control algorithm
Communication
5 – 35°C
0,1°C
TPI or Hysteresis ( 0.2°C to 2°C)
Wired
Boiler - Boiler connection* - Boiler’s
contacts for ON/OFF thermostat
(according to the boiler’s instructions)
L, N - power supply
COM, NO - voltage-free output
SL1 - 230V control input in the control box
Pump
Valve
Output control
COM / NO (voltage-free)
IP30
- fuse
IP protection class
Dimension [mm]
80 x 80 x 22 mm
| General | Details |
|---|---|
| Name | ENGO CONTROLS EASYBATB Wired Thermostat User Guide |
| Make | ENGO CONTROLS |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.19 MB |

ENGO Controls EONE230W Internet Controlled Thermostat User Guide

ENGO CONTROLS EFAN-230W Fan Coil Thermostat User Guide

ENGO CONTROLS FAN-24W 24V Fan Coil Thermostat User Guide

ENGO CONTROLS EASY230W Non-Programmable Wired Thermostat User Guide

ENGO CONTROLS EONE230 Internet Controlled Thermostat User Guide

ENGO CONTROLS EONEBATW, EONEBATB Internet Controlled Thermostat User Manual

ENGO Controls E901WIFI Internet Wireless Thermostat User Guide

ENGO CONTROLS EONE-BATW, EONE-BATB Internet Controlled Thermostat User Guide

ENGO CONTROLS EFAN-24W Fan Coil Thermostat User Guide

ENGO CONTROLS EFAN-230W WIFI 230V Fan Coil Thermostat User Guide

ENGO CONTROLS EASYBATB Wired Thermostat User Guide Overview
Summary of Contents
- Page 1: Connection description for EASY230W / EASY230B Connection description for EASYBATW / EASYBATB Wired, non-programmable thermostat, battery powered (2xAAA) or 230V AC powered. It is used for wired control of heating or cooling devices and systems. Product Compliance: This product complies with the following EU Directives: 2014/53/EU, 2011/65/EU Power supply: 230V or 2xAAA batteries Max current: 3 (1) A Temperature range: 5 – 35°C Display temperature accuracy: 0.1°C Control algorithm: TPI or Hysteresis (0.2°C to 2°C)
- Page 2: WARNING! After entering the service menu, use the buttons to choose a parameter. For the parameter selection to be confirmed, wait 3 seconds. To enter the service menu, press and hold MINUS and PLUS buttons for 5 seconds. The thermostat will go to the home screen. Set the minimum temperature setpoint limit. Set the maximum temperature setpoint limit. Displayed temperature can be calibrated in steps of 0.1°C. The thermostat should be installed in a suitable place, away from sources of heat or cold. Check the current battery status (%). Select whether the thermostat output has to work as Normally Open or Normally Closed.