PRO1 T805 Non Programmable Thermostat Instruction Manual
OPERATING MANUAL
This manual covers the following models:
ꢀ T805
Congratulations on purchasing a
new thermostat. This thermostat was
designed to the highest reliability and
ease of use standards. Thank you for
choosing Pro1.
Caution:
Equipment damage hazard
Do not operate the cooling
system if the outdoor
temperature is below 50˚ F
(10˚ C) to prevent possible
compressor damage.
Table of Contents
Page
Need Help?
Thermostat Quick Reference
Thermostat Operation
2
3
4
6
For assistance with this product please
Customer Care toll-free at 888-Pro1iaq
(776-1427) during normal business hours
(Mon-Fri 9 AM - 6 PM Eastern)
Programming Installation
Contact Us and Warranty Registration
Una versión española de este
manual puede ser descargada
® U.S. Registered Trademark. Patents pending.
Copyright © 2006 Pro1 IAQ, Inc. All rights reserved.
Rev. 0730
1
| General | Details |
|---|---|
| Name | PRO1 T805 Non Programmable Thermostat Instruction Manual |
| Make | PRO1 |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.28 MB |

PRO1 T751i Thermostat Installation Guide

PRO1 T731W Wireless PTAC Non-Programmable Thermostat Installation Guide

PRO1 T701 Digital Non Programmable Thermostat Instruction Manual

PRO1 IAQ T721i Digital WIFI Programmable Thermostat User Manual

PRO1 R250W Wireless System Thermostat Owner’s Manual

PRO1 T725 Thermostat User Guide

PRO1 T755 Heat 2 Cool Dual Fuel Thermostat User Manual

PRO1 T771 Programmable Electronic Thermostat Instructions

PRO1 T805 Non Programmable Thermostat Instruction Manual Overview
Summary of Contents
- Page 1: Operating manual This manual covers the following models: T805 Congratulations on purchasing a new thermostat. This thermostat was designed to the highest reliability and ease of use standards. Caution: Equipment damage hazard Do not operate the cooling system if the outdoor temperature is below 50˚ F (10˚ C) to prevent possible compressor damage. Table of contents Need help? Thermostat quick reference Thermostat operation Programming installation
- Page 2: Thermostat quick reference Getting to know your thermostat Indicates the current room temperature. Displays the user selectable setpoint temperature. Hold is displayed when thermostat program is permanently overridden. System operation indicators: The COOL, HEAT, or FAN icon will display when the system is on. The compressor delay feature is active if these icons are flashing. This thermostat has 4 programmable time periods per day. Replace batteries when the low battery indicator is shown. The low battery indicator is displayed when the AA battery power is low. Insert 2 AA alkaline batteries to power the thermostat.
- Page 3: Thermostat operation Easy to use controls When the battery icon appears, replace your AA batteries immediately. Failure to do so may result in your heating and cooling system becoming inoperable. Auto changeover will switch between heating and cooling as needed. It is very important to make sure the cooling setpoint temperature is at least 3º above the heating setpoint temperature and that the heating setpoint temperature is at least 3º below the cooling setpoint temperature. Selects the operation mode of your HVAC system. Selecting HEAT turns on the heat mode. Selecting COOL turns on the air conditioning mode. Selecting OFF turns both heating and cooling off. Selecting AUTO will turn the HEAT or COOL on as needed. The glow in the dark light button will self illuminate for several hours after exposure to ambient light. This button turns on the display light when pressed. The ON key will run the fan continuously. The AUTO key will cycle the fan on only when the heating or cooling system is on. The programmable fan feature will run the fan continuously during any time period it is programmed to be on. This is the best way to keep the air circulated and to eliminate hot and cold spots in your building. Press the + or - buttons to select the desired room temperature. Use these buttons to set up your programming options.
- Page 4: Programming the thermostat Set time Follow the steps below to set the current time. Press MENU. Press SET TIME. Day of the week will be flashing. This TECH SET key is for installer configuration and should NOT be changed unless you consult your professional heating and air conditioning technician. Use the or key to select the current hour. When using 12-hour time, make sure the correct a.m. or p.m. choice is selected. Press DONE when completed. Set program schedule 5+1+1 To customize your 5+1+1 program schedule, follow these steps. You have to program heat and cool each separately.
- Page 5: Programming the thermostat involves setting a 7-day program schedule. You need to program heat and cool separately. To customize the schedule, select heat or cool using the system key. The filter change reminder will display when the air filter needs to be changed. Time will flash for you to make your time selection for the WAKE time period. You can select ON with the FAN key if you want the fan to run continuously during the WAKE time period. Repeat the steps for Monday's LEAVE, RETURN, and SLEEP time periods. For the remaining days of the week, repeat the same steps. The temporary hold feature allows the thermostat to maintain a setpoint until the next program period begins. Press the RUN SCHED key to exit either temporary or permanent hold.
- Page 6: Contact us information Your new Pro1 thermostat has a 5 year limited warranty. You must register your warranty within 60 days of installation. You can register your new thermostat in 2 ways. Go to the website, select warranty registration and fill out a short registration form. Complete the form below and mail it to the address shown. Pro1 IAQ Warranty Registration: Complete form and mail to: Pro1 IAQ Inc. 2626 W. College Rd.