Home > Pro1 Technologies > Pro1 Technologies Pro1 T701i WiFi Thermostat Installation Guide
Pro1 Technologies Pro1 T701i WiFi Thermostat Installation Guide
Product Installation Guide
Installation Tips
Wall Installation
The thermostat should be installed approximately 4 to 5 feet above the floor.
Select an area with average temperature and good air circulation. Pick an
installation location that is easy for the user to access. The temperature of the
location should be representative of the building.
T701i
Pro1 Technologies
P.O. Box 3377
Springfield, MO 65808-3377
Do not install
thermostat in locations:
Toll Free : 888-776-1427
Hours of Operation: M-F 9AM - 6PM EST
PM-T701i-IM-2219
*PM-T701i-IM-2219*
Hardwire (24V Common Wire)
• Close to hot or cold air ducts
• That are in direct sunlight
• With an outside wall behind the
thermostat
• In areas that do not require
conditioning
• Where there are dead spots or
drafts (in corners or behind doors)
• Where there might be concealed
chimneys or pipes
Power Type
Thermostat Application Guide
Description
Gas or Oil Heat
Yes
Yes
No
No
A trained, experienced
technician must install this product.
Electric Furnace
Heat Pump (No Aux. or Emergency Heat)
Heat Pump (With Aux. or Emergency Heat)
Multi-Stage Systems
Carefully read these
instructions. You could damage this
product or cause a
hazardous condition if you fail to
follow these instructions.
No
Yes
Yes
Heat Only Systems
Cool Only Systems
No
Millivolt
Removing The Private Label Badge
Una version en espanol de este
manual se puede descargar en la
pagina web de la compania.
Table of Contents
Page
Specifications
1
2
3
4
5-6
Gently slide a screwdriver into the
bottom edge of the badge. Gently
turn the screwdriver counter
Installation Tips
Thermostat Quick Reference
Subbase Installation
Wiring
clockwise. The badge is held on by
a magnet in the well of the battery
door. The badge should pry off easily.
Technician Setup
WIFI Setup
Specifications
7-8
9-11
12
Use the bevel on lower ridge
DO NOT USE FORCE.
All of our thermostats use the same
universal magnetic badge. Visit the
company website to learn more about
our free private label program.
Magnet in door
U.S. Registered Trademark. Patents pending
Copyright 2022 All Rights Reserved.
1
2
Rev. 2251
Thermostat Quick Reference
Subbase Installation
Horizontal Mount
For horizontal mount put one
screw on the left and one screw
on the right.
LCD Display
Glow in the dark light button
Fan Button
Vertical Mount
For vertical mount put one
screw on the top and one screw
on the bottom.
System Button
Temperature Setpoint Buttons
Private Label Badge
Electrical Hazard
Failure to disconnect the power before
beginning to install this product can cause
electrical shock or equipment damage.
Set At
Mercury Notice
NOTE: To ensure a solid fit between
the thermostat and subbase:
1. Mount subbase on a flat wall.
2. Use provided screws.
COOL ON
HEAT ON
FAN ON
All of our products are mercury free.
However, if the product you are replacing
contains mercury, dispose of it properly.
Your local waste management authority
can give you instructions on recycling and
proper disposal.
3. Ensure drywall anchors are flush with wall.
4. Push wires into wall.
Mount Thermostat
Em.Heat
STAGES AutoCool
Indicates the current room temperature
1
2
3
Setpoint: Displays the selected setpoint temperature.
System Operation Indicators: The COOL ON, HEAT ON or FAN ON will display
when the COOL, HEAT, or FAN is on. The compressor delay feature is active if these
are flashing.
Align the 4 tabs on the subbase
with corresponding slots on the
back of the thermostat, then
push gently until the
WIFI Indicator: Shown when connected to WiFi.
thermostat snaps in place.
Globe: Globe is displayed if an energy efficient temperature has been selected.
Fan: Indicates the current fan setting.
Stages: +1 will appear in the display when the first stage of heat or cool is
on.
7
System: Indicates current system mode setting.
4
| General | Details |
|---|---|
| Name | Pro1 Technologies Pro1 T701i WiFi Thermostat Installation Guide |
| Make | Pro1 Technologies |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.26 MB |

Pro1 Technologies T855iSH Wall Thermostat Instruction Manual

Pro1 Technologies T751 Non-Programmable Digital Thermostat Instruction Manual

Pro1 Technologies Pro1 T701i WiFi Thermostat Installation Guide Overview
Summary of Contents
- Page 1: Product installation guide The thermostat should be installed approximately 4 to 5 feet above the floor. Select an area with average temperature and good air circulation. The temperature of the location should be representative of the building. Do not install thermostat in locations close to hot or cold air ducts, in direct sunlight, with an outside wall behind the thermostat, in areas that do not require conditioning, where there are dead spots or drafts, or where there might be concealed chimneys or pipes. A trained, experienced technician must install this product. Carefully read these instructions to avoid damaging the product or causing a hazardous condition. Gently slide a screwdriver into the bottom edge of the badge to remove it. All of our thermostats use the same universal magnetic badge. Failure to disconnect the power before beginning to install this product can cause electrical shock or equipment damage. All of our products are mercury free.
- Page 2: Wiring Caution: Electrical hazard. Failure to disconnect the power before beginning to install this product can cause electrical shock or equipment damage. If you are replacing a thermostat, make note of the terminal connections on the thermostat that is being replaced. A 24 VAC 500mA common connection is required with this thermostat. All components of the control system and the thermostat installation must conform to Class II circuits per the NEC Code. This thermostat requires a 24V common wire to the C terminal. Do not overtighten terminal block screws, as this can damage the terminal block. Devices such as a float switch that mechanically break circuits should be installed so that they break the control wire (Y) not the power (R). Technician Setup Menu Press and hold the + and - buttons for 3 seconds to enter tech setup. This feature allows you to set a maximum heat setpoint value.
- Page 3: WIFI setup steps are intended for viewing information and resetting your WIFI connection. The WIFI reset process is necessary for applications like replacing WIFI routers or changing networks. To reset the WIFI connection, press and hold the + and – buttons together for 3 seconds, then press and hold the WIFI button. You can change settings using the + or - buttons and navigate through steps with the lower left and right buttons. To exit tech setup, press and hold the + and - buttons for 3 seconds or wait 60 seconds. The thermostat will display “WIFI RESET” indicating it is no longer connected to the local WIFI network. The WIFI firmware identification number can be used for troubleshooting. The control range of temperature is 44˚F to 90˚F (7˚C to 32˚C). The power source required is 18 to 30 VAC, NEC Class II, 50/60 Hz for hardwire. Operating humidity should not exceed 90% non-condensing maximum.