OPERATING YOUR THERMOSTAT
IMPORTANT!
Choose the Fan Setting (Auto or On)
Manual Operation (Bypassing the Program)
Programmable Thermostats
Set the FAN Switch to Auto or On.
Fan Auto is the most commonly selected setting and runs the
fan only when the heating or cooling system is on.
Fan On runs the fan continuously for increased air circulation
or to allow additional air cleaning.
Press
or
and the HOLD button and adjust the tem-
perature wherever you like. This will override the program.
The HOLD feature bypasses the program and allows you
to adjust the temperature manually, as needed. Whatever
temperature you set in HOLD will be maintained 24 hours
a day, until you manually change the temperature or press
Run Schedule to cancel HOLD and resume the programmed
schedule.
Choose the System Setting
(Heat, Off, Cool, Auto)
Press the SYSTEM button to select:
Heat: Thermostat controls only the heating system.
Program Override (Temporary Override)
Off: Heating and Cooling systems are off.
Press
or
buttons to adjust the temperature. This will
Cool: Thermostat controls only the cooling system.
override the temperature setting until the next programmed
time. To cancel the temporary setting at any time and return
to the program, press Run Schedule. If the SYSTEM button
is pressed to select AUTO the thermostat will change to Heat
or Cool, whichever ran last. If it switches to heat but you want
cool, or it changes to cool but you want heat, press both
Auto: Auto Changeover is used in areas where both heating
and cooling may be required on the same day. AUTO allows
the thermostat to automatically select heating or cooling
depending on the indoor temperature and the selected heat
and cool temperatures. When using AUTO, be sure to set the
Cooling temperatures more than 1° Fahrenheit higher than
the heating temperature.
and
buttons simultaneously to change to the other mode.
Manual Operation for Non-Programmable
Thermostats Mode
Press the SYSTEM button to select Heat or Cool and use
the
or
buttons to adjust the temperature to your
desired setting. After selecting your desired settings you can
also press the SYSTEM button to select AUTO to allow
the thermostat to automatically change between Heat and
Cool.
PROGRAMMING (For Programmable Model Only)
Set Current Time and Day
Enter the Heating Program
1) Press Menu and then Time button once. The display
will show the hour only.
1) Press SYSTEM button to select "Heat" in the system
switch area indicating the active mode being pro-
grammed.
2) Press and hold either the
or
button until you
reach the correct hour and AM/PM designation (AM be-
gins at midnight, PM begins at noon).
3) Press Time once again. The display window will show
the minutes only.
2) Press the Menu button and then press Schedule.
3) The top of the display will show the day(s) being pro-
grammed. The time and temperature (flashing) are also
displayed. "1" will also be displayed to indicate the period.
4) Press and hold either the
reach the correct minutes.
5) Press Time once again. The display will show the day
of the week.
or
button until you
4) Press
or
button to change the temperature to
your selected temperature for the 1st heating period.
5) Press Time button, time will flash.
6) Press
1st period.
7) The time will change in 15 minute increments.
8) After you have set the time and the temperature for
the period to begin, press Schedule to advance to the
next program period.
or
button to adjust the start time for the
6) Press the
day of the week.
7) Press Run to exit the Time mode.
or
button until you reach the current
9) Repeat steps 2 through 8 until all of the program times
and temperatures are set for all program periods on
that day.
10)Press Schedule to the next day and repeat steps 2
through 9.
11)When programming is complete and all of the times and
temperatures match your desired heating schedule, press
Run Schedule. The thermostat will now run your program.
Enter the Cooling Program
1) Press SYSTEM button to select "Cool" in the system
switch area indicating the active mode being pro-
grammed.
2) Follow Enter Heating Program instructions for entering
cooling times and temperatures.
6
| General | Details |
|---|---|
| Name | WHITE-RODGERS 1F86-0471 Blue Single 1 1 Stage Thermostat Instruction Manual |
| Make | WHITE RODGERS |
| Language | English |
| Filetype | PDF (Download) |
| File size | 0.51 MB |

White-Rodgers 1E78 Non Programmable Heat Only Thermostat User Manual

White-Rodgers 1F97-1277 Big Blue Single Stage Thermostat User Manual

White-Rodgers 1F56N-444 Thermostat User Manual

White-Rodgers 1F83-277 Heating & Air Conditioning Auto Changeover Heat Pump Thermostat User Manual

White-Rodgers M30 Thermostat Instruction Manual

WHITE-RODGERS 1F51N-619 Low Voltage Evaporative Cooler Thermostat Instruction Manual

WHITE-RODGERS 1F95-1277 Universal Thermostat Owner’s Manual

White Rodgers 1F78-151 Non Programmable Thermostat Instructions

WHITE RODGERS 1F80-51 Programmable Electronic Digital Thermostat Instruction Manual

WHITE-RODGERS 1F90-71 5-Day 2-Day Electronic Digital Thermostat Instruction Manual