INSTALLER/CONFIGURATION MENU
To enter the menu: Press the Menu touch key. Press and hold for 5 seconds the Installer Config touch key. This displays
screen reference #1 in the table below. Screen Reference numbers appear in top right corner of display. Press
to the next menu item or to return to a previous menu item. Press or to change a menu item option. Shaded items are
to advance
not available if selected for Non-Programmable. Write the options selected in the "Option Selected" column of the menu.
Installer Note: To default the programming, clock and Configuration Menu to the Factory Default Settings, press the
and SYSTEM keys simultaneously. The thermostat display will go blank for a few seconds, and then all segments will display
,
momentarily. For heat pump systems, Configuration Menu items 1 and 3 must be set to match the heat pump system.
CONFIGURATION MENU
Screen
SS1 HP1 Press
Displayed
Factory
(Default)
Comments
Option
Selected
Press
or
Reference MS2 HP2
Number
key
to select from
listed options
HP 1, HP 2, SS 1
1
MS 2
Selects Multi-Stage (MS2, No Heat Pump), Heat Pump 1
(HP1, 1 compressor), Heat Pump 2 (HP2, 2 compressor
or 2 speed compressor), or Single Stage.
2
3
(GAS)
0b (0)
ELE
b
GAS setting: furnace controls blower.
ELE setting: thermostat controls blower.
Selects Reversing Valve (This item is only to appear if HP1 or HP2
is selected above.)
4
5
Days, (7) P
5 or 0
Programs per week. (7 days, 5+1+1 days or non-programmable)
(4) PS
2
Programs per day.
4 = Morning, Day, Evening, Night
2 = Day, Night
Not available if 4 is 0
6
Cool-Off-
Heat-Auto
Cool-Off-Heat, Heat Off, System switch configuration in non heat pump mode.
Heat, Cool-Off, Auto Off
Cool-Off-Heat-
Em-Auto
Cool-Off-Heat-Em,
Off-Em-Auto
System switch configuration, heat pump mode.
7
8
(On) E
OFF
SL
Selects Energy Management Recovery. Not available if 4 is 0
Selects Adjustable Anticipation, cycle rate, Heat
Selects Adjustable Anticipation, cycle rate, Cool
(FA) Heat, Cr
(FA) Cool, Cr
(FA) Cr/AU, Em
9
SL
10
SL
Selects Adjustable Anticipation, cycle rate auxiliary, (This item is
only to appear if HP1 or HP2 is selected above).
11
12
13
(OFF) CL
On
OFF
Selects Compressor Lockout.
(On) dL
Selects Continuous Display backlight.
0
(Temperature)
5, LO to 5, HI
Selects Adjustable Ambient Temperature Display [range -5 (LO)
to +5 (HI)].
14
15
16
17
°F
°C
Selects °F/°C Display (temperature units in Fahrenheit or Celsius).
(On) b
OFF
OFF
OFF
Selects audible Beeper On/Off.
(On) dS
Selects Daylight Saving Time calculation.
(On) Heat, AS
Selects Automatic Schedule for comfort temperature Programming,
heat mode. Not available if 4 is 0
18
(On) Cool, AS
OFF
Selects Automatic Schedule for comfort temperature Programming,
cool mode. Not available if 4 is 0
19
20
(OFF) CS
On
Selects Cool Savings Feature On of Off.
CS Cool Savings
(3)
1-2-3-4-5-6
Selects amount of Cool Savings adjustment.
21
22
(Off) CO
On
On
Select Compressor Optimization (not available on earlier models)
(OFF) CA
Selects Comfort Alert Feature On or Off. (not available on earlier
models)
23
24
25
(99) Heat, HL
62-98
46-82
TEMPERATURE LIMIT, HEAT (max. heat set point).
TEMPERATURE LIMIT, COOL (min. cool set point).
Selects Keypad Lockout.
(45) Cool, LL
L (total), P (partial),
Temperature Limit
(limited temperature range)
OFF,
Keypad Lockout
26
000
001-999
Selects Keypad Lockout Combination (active only if keypad Lockout
is selected).
27
28
(On) Heat, FS
(On) Cool, FS
OFF
OFF
Fast second stage of heat (not available if SS1 is selected above).
Fast second stage of cool (not available if SS1 or HP1 is selected
above).
29
30
31
Remote (OFF)
Remote, In
(On) LS
On
Outdoor Remote
OFF
Remote temperature sensor, enable/disable.
Remote temperature sensor (Indoor/Outdoor).
Local temp. Sensor enable/disable (only when Indoor Remote is
selected On).
32
(OFF) dF
On
Selects Dual Fuel feature On or OFF (this item appears if HP1 or
HP2 is selected above).